Invitrogen™ Qubit™ Flex Fluorometer

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Sample Volume: 1 to 20 µL
Excitation Wavelength:
Blue LED (max 460–480 nm)
Red LED (max 620–640 nm)

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application molecular biology Warranty 1 Year
    Storage Temperature Room Temperature
    Product Type Laboratory Equipment
    Product Brand Thermo Fisher Scientific™
    Product Grade Molecular Biology

    The Qubit™ Flex Fluorometer is an advanced benchtop device designed for the quantification of DNA, RNA, microRNA, and protein. With the capability to measure up to eight samples simultaneously, it offers improved throughput, accuracy, and reproducibility compared to traditional single-sample fluorometers. The Qubit Flex Fluorometer integrates seamlessly with Qubit reagents, enabling a highly optimized workflow for molecular biology applications.

    Key Features:

    FeatureDescription
    ThroughputMeasures up to 8 samples simultaneously, reducing assay time by 50%.
    AccuracyHigh sensitivity for low-concentration samples; avoids interference from non-target molecules.
    Sample VolumeRequires only 1–20 μL per sample.
    Data ExportIncludes WiFi dongle, USB drive support, and direct computer connectivity for flexible data transfer.
    User Interface8-inch color touchscreen with intuitive navigation and multi-language support (English, French, Spanish, Italian, German, simplified Chinese, Japanese).
    On-Board CalculatorsIntegrated tools for reagent selection, working solution preparation, and molarity calculations.
    Verification ProgramPre-loaded performance verification test ensures instrument reliability.
    SmartStart Digital ExperienceIncludes interactive, visual guides for instrument installation, operation, and maintenance.
    Extended WarrantyComes with a three-year warranty, including factory-certified replacements for repairs.

    Advantages Over Traditional UV Spectrophotometry:

    AspectQubit Flex FluorometerUV Spectrophotometry
    SensitivityHigh; detects low-concentration DNA, RNA, and proteins.Low; struggles with dilute samples.
    SpecificityFluorescent dyes bind only to target molecules.Measures all molecules absorbing at 260 nm.
    ThroughputMeasures up to 8 samples simultaneously.Single sample at a time.
    Interference from ContaminantsMinimal; fluorescence only when bound to targets.Significant; contaminants affect readings.
    Ease of UseIntuitive touchscreen and preloaded calculators.Manual calibration and calculations.

    Applications:

    ApplicationUse Case
    DNA QuantificationPreparation of NGS libraries, plasmids, PCR products, and genomic DNA.
    RNA QuantificationMeasuring total RNA, mRNA, and microRNA for transcriptomics.
    Protein QuantificationAnalysis of purified proteins, lysates, serum, and plasma samples.
    MicroRNA QuantificationDetermining concentrations of microRNA for regulatory and therapeutic studies.

    Specifications:

    SpecificationDetails
    Sample Volume1–20 μL
    Excitation Wavelength460–480 nm (Blue LED), 620–640 nm (Red LED)
    Product LineQubit
    TypeFluorometer
    ConnectivityWiFi Dongle, USB drive, or direct USB connection
    Shipping ConditionRoom temperature
    Supported LanguagesEnglish, French, Spanish, Italian, German, simplified Chinese, Japanese
    WarrantyThree years, including factory-certified refurbished replacement for repairs
    For Use With ApplicationsDNA, RNA, microRNA, and protein quantification.

    Comparison: Qubit Flex Fluorometer vs Other Qubit Models and Other Fluorometers

    FeatureQubit Flex FluorometerQubit 4 FluorometerThermo Scientific NanoDrop™ OnePromega Quantus™ Fluorometer
    Sample CapacityUp to 8 samples simultaneouslySingle sampleSingle sampleSingle sample
    ThroughputHigh throughput (up to 50% faster)Standard throughputStandard throughputStandard throughput
    Assay CompatibilityDNA, RNA, microRNA, proteinDNA, RNA, proteinDNA, RNA, proteinDNA, RNA
    AccuracyHigh accuracy with 1–20 µL, fluorescence-basedHigh accuracy with 1–20 µL, fluorescence-basedModerate accuracy, UV absorbance detects all molecules at 260 nmHigh accuracy, fluorescence-based
    Optimized ReagentsDesigned specifically for Qubit assay kits for reliable resultsDesigned for Qubit assay kits for reliable resultsCompatible with nucleic acid quantitation without reagentsCompatible with fluorescence dye kits (e.g., Quant-iT)
    Time to Results<5 seconds per sample, simultaneous measurement reduces time<3 seconds per sample<10 seconds per sample<5 seconds per sample
    Data Export OptionsWi-Fi, USB drive, USB cableWi-Fi, USB drive, USB cableUSB, Ethernet, touchscreen displayUSB
    Screen8-inch color touchscreen5.7-inch color touchscreen7-inch color touchscreenSmall monochrome display
    Special FeaturesBuilt-in molarity calculator; simultaneous measurement reduces variabilityPreloaded RNA integrity assay, reagent calculatorBuilt-in contaminant analysis for UV spectraSimple, budget-friendly option
    PortabilityBenchtop, not portablePortable benchtopPortable benchtopPortable benchtop
    Application SuitabilityBest for high-throughput labs with diverse sample typesBest for low-to-moderate throughput labsRoutine nucleic acid quantification; less suited for low concentrationsBest for low-volume, high-accuracy applications
    ConsumablesRequires Qubit Flex reagents, assay kits, and assay tubesRequires Qubit reagents, assay kits, and assay tubesNo proprietary reagents required, works with standard nucleic acid samplesRequires fluorescence dye kits

    Workflow and Operation:

    1. Prepare Assay Reagents:
      • Use the on-board calculator to determine the reagent volumes required for your assay.
    2. Load Samples:
      • Pipette 1–20 μL of sample into the appropriate assay tubes and mix with the working solution.
    3. Run Assay:
      • Place up to 8 samples into the Qubit Flex Fluorometer and start the assay using the touchscreen interface.
    4. Review Results:
      • Results are displayed in seconds, with options to export data via USB, WiFi, or direct cable.
    5. Post-Run Maintenance:
      • Perform verification tests using preloaded programs to ensure consistent performance.

    Package Includes:

    ComponentDetails
    Qubit™ Flex FluorometerIncludes 8-sample measurement capability.
    Qubit™ Flex Power CordRequired for instrument operation.
    Wi-Fi DongleFor cloud-based data export.

    Benefits:

    • Throughput: Process multiple samples faster, reducing overall workflow time.
    • Accuracy: Avoids contamination interference for highly reliable results.
    • Ease of Use: Simplified operation with digital tools and an intuitive touchscreen.
    • Cost-Effective: Reduces reagent waste with precise volume requirements.

    For researchers in genomics, transcriptomics, and proteomics, the Qubit Flex Fluorometer offers an efficient and reliable solution for accurate quantification.

    Product Specification not found.

    Accessory Products


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    21098





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review




    Showing 0 Of 0