Agilent 4200 TapeStation System
Catalog No :
CAS Number :
Brand :
In Stock
Including laptop PC, software, vortexer, accessories, plastic consumables and user information
Specifications:
Application | Capillary Electrophoresis |
Storage Temperature | Ambient |
Product Type | Molecular Biology Equipment |
Product Brand | Agilent |
The Agilent 4200 TapeStation System is a high-throughput, fully automated electrophoresis platform designed for DNA and RNA sample quality control (QC) in next-generation sequencing (NGS), biobank workflows, and molecular biology applications. It provides scalable, user-independent analysis of 1 to 96 samples per run with constant cost per sample, offering high flexibility and efficiency for labs processing variable sample numbers.
With ready-to-use ScreenTape technology, the 4200 TapeStation enables rapid, reproducible assessment of nucleic acid integrity, sizing, and concentration, making it an essential tool for automated, high-throughput DNA and RNA quality control.
Key Features & Benefits
- Fully Automated Sample Processing with Minimal Hands-On Time
- Enables unattended analysis of 1 to 96 DNA/RNA samples.
- Provides user-independent results, eliminating manual variability.
- Consistent Per-Sample Cost with Scalable Throughput
- Analyzes any sample number between 1 and 96 without increasing costs.
- Offers high flexibility for small and large batches.
- Dual Compatibility for DNA & RNA Quality Control
- Easily switch between DNA and RNA ScreenTape assays.
- Ensures precise integrity assessment using DIN (DNA Integrity Number) and RINe (RNA Integrity Number equivalent).
- Fast, High-Throughput Electrophoresis with Reproducible Results
- Delivers results in 1–2 minutes per sample, processing 96 samples in under 90 minutes.
- Provides high precision in fragment sizing, concentration, and integrity assessment.
- No Cross-Contamination with ScreenTape Technology
- Each sample is processed in a separate lane, eliminating carryover concerns.
- Uses disposable loading tips for contamination-free workflows.
- Low Sample Input & High Sensitivity Analysis
- Requires only 1–2 µL of DNA or RNA per sample.
- Works with low-concentration samples while maintaining accuracy.
- Compact & Low Maintenance Design
- Features easy self-maintenance tasks to reduce downtime.
- Offers lowest cost of ownership compared to alternative systems.
Product Specifications
Feature | Details |
---|---|
Product Name | Agilent 4200 TapeStation System |
Technology | Automated Electrophoresis |
Number of Samples per Run | 1 to 96 |
Analysis Time | 1–2 minutes per sample / <90 minutes for 96 samples |
Assay Compatibility | DNA, RNA, Genomic DNA, Cell-Free DNA |
Data Output | RNA Integrity Number (RINe), DNA Integrity Number (DIN) |
Sample Volume Required | 1–2 µL |
Carryover Prevention | Individual Loading Tips for Each Sample |
Self-Maintenance Tasks | Yes, for Lower Cost of Ownership |
Voltage | 100–240 VAC |
Power Consumption | 50 VA |
Software Included | Yes (with Laptop PC) |
Preventive Maintenance (PM) Included? | No (Ordered Separately) |
ScreenTape Consumables & Reagents Included? | No (Ordered Separately) |
Shipping Conditions | Standard Packaging |
Use Cases & Applications
1. Next-Generation Sequencing (NGS) Library Quality Control
- Ensures High-Quality DNA/RNA for NGS Library Prep
- Measures RINe for RNA integrity and DIN for DNA fragmentation assessment.
- Detects adapter dimers, incomplete ligation products, and low-yield libraries.
- Automated Electrophoresis for High-Throughput NGS Pipelines
- Provides reproducible QC data for sample selection and library validation.
- Reduces workflow bottlenecks in sequencing labs.
2. Genomic & Cell-Free DNA Integrity Assessment
- Genomic DNA Quality Control for Whole-Genome Sequencing
- Measures DNA fragmentation patterns with DIN scoring.
- Prevents degraded or low-quality DNA from impacting sequencing runs.
- cfDNA & Liquid Biopsy Analysis for Oncology Research
- Supports quality assessment of circulating DNA (cfDNA) and tumor-derived DNA.
- Provides precise fragment size distribution for biomarker studies.
3. RNA Quality Control for Gene Expression & Transcriptomics
- Determines RNA Integrity for qPCR & Microarrays
- Rapidly assesses total RNA and mRNA quality for transcriptomics research.
- Ensures RNA integrity before downstream analysis.
- Optimized for Single-Cell RNA Sequencing (scRNA-Seq)
- Validates RNA input quality for single-cell applications.
- Detects partial RNA degradation in low-yield samples.
4. Clinical Research & Biopharmaceutical Development
- Reliable Sample QC for Drug Discovery & Cell Therapy Research
- Facilitates standardized RNA/DNA analysis in regulated environments.
- Supports assay development in molecular diagnostics.
- Essential for CRISPR & Genome Editing Workflows
- Enables precise DNA quality assessment for gene-editing efficiency.
- Ensures accurate genomic DNA integrity in CRISPR-based studies.
Instructions for Use
- Load Samples & ScreenTape Device:
- Place 1 to 96 samples in the TapeStation sample tray.
- Insert the appropriate DNA or RNA ScreenTape cartridge.
- Run the TapeStation Analysis:
- Start the automated electrophoresis process via software.
- The system automatically processes samples in 1–2 minutes per sample.
- Interpret Data & Export Results:
- View electropherogram traces & gel-like images for fragment size analysis.
- Export results in PDF, CSV, or LIMS-compatible formats.
Storage & Handling Instructions
- Storage Conditions:
- Store the instrument in a temperature-controlled laboratory.
- Keep ScreenTape reagents at recommended conditions (4°C or RT, depending on assay type).
- Handling Precautions:
- Follow standard lab safety protocols when handling nucleic acid samples.
- Ensure proper calibration and maintenance for reproducible results.
- Disposal Guidelines:
- Dispose of used ScreenTape cartridges and reagents as per biosafety waste regulations.
Why Choose the Agilent 4200 TapeStation System?
✅ Fully automated DNA/RNA integrity analysis with minimal hands-on time
✅ Flexible throughput (1 to 96 samples) with constant per-sample cost
✅ Proven ScreenTape technology for high reproducibility & accuracy
✅ Fast electrophoresis results (1–2 minutes per sample)
✅ No cross-contamination with individual sample lanes & loading tips
The Agilent 4200 TapeStation System is an advanced electrophoresis platform designed for high-throughput, automated nucleic acid QC, ensuring precise DNA/RNA quality control for NGS, qPCR, and biobank workflows.