Agilent 4200 TapeStation System

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Including laptop PC, software, vortexer, accessories, plastic consumables and user information

条款和条件
30天退款保证
运输:2-3 个工作日

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application Capillary Electrophoresis
    Storage Temperature Ambient
    Product Type Molecular Biology Equipment
    Product Brand Agilent

    The Agilent 4200 TapeStation System is a high-throughput, fully automated electrophoresis platform designed for DNA and RNA sample quality control (QC) in next-generation sequencing (NGS), biobank workflows, and molecular biology applications. It provides scalable, user-independent analysis of 1 to 96 samples per run with constant cost per sample, offering high flexibility and efficiency for labs processing variable sample numbers.

    With ready-to-use ScreenTape technology, the 4200 TapeStation enables rapid, reproducible assessment of nucleic acid integrity, sizing, and concentration, making it an essential tool for automated, high-throughput DNA and RNA quality control.

    Key Features & Benefits

    1. Fully Automated Sample Processing with Minimal Hands-On Time
      • Enables unattended analysis of 1 to 96 DNA/RNA samples.
      • Provides user-independent results, eliminating manual variability.
    2. Consistent Per-Sample Cost with Scalable Throughput
      • Analyzes any sample number between 1 and 96 without increasing costs.
      • Offers high flexibility for small and large batches.
    3. Dual Compatibility for DNA & RNA Quality Control
      • Easily switch between DNA and RNA ScreenTape assays.
      • Ensures precise integrity assessment using DIN (DNA Integrity Number) and RINe (RNA Integrity Number equivalent).
    4. Fast, High-Throughput Electrophoresis with Reproducible Results
      • Delivers results in 1–2 minutes per sample, processing 96 samples in under 90 minutes.
      • Provides high precision in fragment sizing, concentration, and integrity assessment.
    5. No Cross-Contamination with ScreenTape Technology
      • Each sample is processed in a separate lane, eliminating carryover concerns.
      • Uses disposable loading tips for contamination-free workflows.
    6. Low Sample Input & High Sensitivity Analysis
      • Requires only 1–2 µL of DNA or RNA per sample.
      • Works with low-concentration samples while maintaining accuracy.
    7. Compact & Low Maintenance Design
      • Features easy self-maintenance tasks to reduce downtime.
      • Offers lowest cost of ownership compared to alternative systems.

    Product Specifications

    FeatureDetails
    Product NameAgilent 4200 TapeStation System
    TechnologyAutomated Electrophoresis
    Number of Samples per Run1 to 96
    Analysis Time1–2 minutes per sample / <90 minutes for 96 samples
    Assay CompatibilityDNA, RNA, Genomic DNA, Cell-Free DNA
    Data OutputRNA Integrity Number (RINe), DNA Integrity Number (DIN)
    Sample Volume Required1–2 µL
    Carryover PreventionIndividual Loading Tips for Each Sample
    Self-Maintenance TasksYes, for Lower Cost of Ownership
    Voltage100–240 VAC
    Power Consumption50 VA
    Software IncludedYes (with Laptop PC)
    Preventive Maintenance (PM) Included?No (Ordered Separately)
    ScreenTape Consumables & Reagents Included?No (Ordered Separately)
    Shipping ConditionsStandard Packaging

    Use Cases & Applications

    1. Next-Generation Sequencing (NGS) Library Quality Control

    • Ensures High-Quality DNA/RNA for NGS Library Prep
      • Measures RINe for RNA integrity and DIN for DNA fragmentation assessment.
      • Detects adapter dimers, incomplete ligation products, and low-yield libraries.
    • Automated Electrophoresis for High-Throughput NGS Pipelines
      • Provides reproducible QC data for sample selection and library validation.
      • Reduces workflow bottlenecks in sequencing labs.

    2. Genomic & Cell-Free DNA Integrity Assessment

    • Genomic DNA Quality Control for Whole-Genome Sequencing
      • Measures DNA fragmentation patterns with DIN scoring.
      • Prevents degraded or low-quality DNA from impacting sequencing runs.
    • cfDNA & Liquid Biopsy Analysis for Oncology Research
      • Supports quality assessment of circulating DNA (cfDNA) and tumor-derived DNA.
      • Provides precise fragment size distribution for biomarker studies.

    3. RNA Quality Control for Gene Expression & Transcriptomics

    • Determines RNA Integrity for qPCR & Microarrays
      • Rapidly assesses total RNA and mRNA quality for transcriptomics research.
      • Ensures RNA integrity before downstream analysis.
    • Optimized for Single-Cell RNA Sequencing (scRNA-Seq)
      • Validates RNA input quality for single-cell applications.
      • Detects partial RNA degradation in low-yield samples.

    4. Clinical Research & Biopharmaceutical Development

    • Reliable Sample QC for Drug Discovery & Cell Therapy Research
      • Facilitates standardized RNA/DNA analysis in regulated environments.
      • Supports assay development in molecular diagnostics.
    • Essential for CRISPR & Genome Editing Workflows
      • Enables precise DNA quality assessment for gene-editing efficiency.
      • Ensures accurate genomic DNA integrity in CRISPR-based studies.

    Instructions for Use

    1. Load Samples & ScreenTape Device:
      • Place 1 to 96 samples in the TapeStation sample tray.
      • Insert the appropriate DNA or RNA ScreenTape cartridge.
    2. Run the TapeStation Analysis:
      • Start the automated electrophoresis process via software.
      • The system automatically processes samples in 1–2 minutes per sample.
    3. Interpret Data & Export Results:
      • View electropherogram traces & gel-like images for fragment size analysis.
      • Export results in PDF, CSV, or LIMS-compatible formats.

    Storage & Handling Instructions

    • Storage Conditions:
      • Store the instrument in a temperature-controlled laboratory.
      • Keep ScreenTape reagents at recommended conditions (4°C or RT, depending on assay type).
    • Handling Precautions:
      • Follow standard lab safety protocols when handling nucleic acid samples.
      • Ensure proper calibration and maintenance for reproducible results.
    • Disposal Guidelines:
      • Dispose of used ScreenTape cartridges and reagents as per biosafety waste regulations.

    Why Choose the Agilent 4200 TapeStation System?

    Fully automated DNA/RNA integrity analysis with minimal hands-on time

    Flexible throughput (1 to 96 samples) with constant per-sample cost

    Proven ScreenTape technology for high reproducibility & accuracy

    Fast electrophoresis results (1–2 minutes per sample)

    No cross-contamination with individual sample lanes & loading tips

    The Agilent 4200 TapeStation System is an advanced electrophoresis platform designed for high-throughput, automated nucleic acid QC, ensuring precise DNA/RNA quality control for NGS, qPCR, and biobank workflows.

    Product Specification not found.

    Accessory Products


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    29380





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review




    Showing 0 Of 0