Skip to Content
Books & Reference Materials
Category Image
Extraction Systems
Category Image
Industrial Instruments
Category Image
Glassware & Plasticware
Category Image
Transfection & Cloning
Category Image
Laboratory Quality Control Solutions
Category Image
Entomology Supplies
Category Image
Sample Preparation
Category Image

Thermo Scientific™ Pierce™ Protein A Chromatography Cartridges

(0 review)
SKU: 89924
UoM: sngls
Inquiry Required

  • Pack Size
Store Availability & Pickup
LabMart Limited - Tamale
NS-246, Via, 4388 Tamale-Kumbungu Rd, Tamale, Northern Region, Ghana
Not available
LabMart Limited
10 Rcecourse street, Accra, Greater Accra Region, Ghana
Not available
Add to quote
MOQ : 1.0 sngls
Estimated delivery Estimated delivery: 4-8 weeks
Telecel AirtelTigo Maestro Mastercard Visa MTN

Thermo Scientific™ Pierce™ Protein A Chromatography Cartridges are ready-to-use, pre-packed affinity columns designed for efficient purification of IgG antibodies from serum, ascites fluid, and cell culture supernatants. These cartridges are pre-filled with Protein A Plus Agarose, a high-capacity resin that combines native Protein A with crosslinked 6% beaded agarose (CL-6B) for high-yield and high-purity antibody recovery.

Engineered for both manual and automated workflows, these cartridges are compatible with syringes, peristaltic pumps, and major FPLC/ÄKTA™ systems. Each cartridge includes a connection accessory pack for Luer-Lok or 1/16” tubing fittings.

Key Features & Benefits

  • Pre-Packed, Ready-to-Use Cartridges
    Simplify your antibody purification workflow with high-reproducibility and reduced setup time.
  • High Binding Capacity
    Binds >34 mg human IgG/mL resin; ideal for purifying large antibody quantities.
  • Stable & Reusable Resin
    Low leaching, covalent ligand attachment ensures stability through multiple purification cycles.
  • Versatile Species Compatibility
    Binds strongly to human, rabbit, pig, dog, and cat IgG subclasses. Moderate to weak binding to some mouse IgG subclasses (not recommended for IgG1).
  • AminoLink™ Coupling Chemistry
    Provides stable amide bond linkage between Protein A and agarose beads; minimizes nonspecific binding.
  • Flexible Integration
    Directly connects to chromatography systems or syringes without additional hardware.

Resin & Cartridge Specifications

FeatureDetails
Stationary PhaseProtein A Plus Agarose
Resin BaseCrosslinked 6% beaded agarose (CL-6B)
Protein A SourceNative (Staphylococcus aureus-derived)
Ligand Immobilization MethodAminoLink Coupling Chemistry (amide bonds)
Binding Capacity>34 mg/mL (Human IgG)
Column FormatCartridges: 1 mL or 5 mL
CompatibilitySyringe, FPLC, ÄKTA™, peristaltic pump
ReusabilityYes – regenerable
Storage Conditions4°C to 8°C, do not freeze

Applications

  • Antibody Purification
    • Polyclonal and monoclonal IgG from serum, ascites, and hybridoma culture media
  • Protein A Affinity Capture
    • Efficient recovery of Fc-region binding IgG subclasses
  • Small- to Mid-Scale Chromatography
    • Suitable for laboratory-scale and pilot-scale purifications
  • Immunology & Proteomics Workflows
    • Downstream use in ELISA, Western blot, conjugation, and labeling


Thermo Scientific™ Pierce™ Protein A Chromatography Cartridges deliver high-efficiency IgG purification with a format that suits both automated systems and manual benchwork. Backed by high-binding-capacity resin, low nonspecific binding, and stable ligand attachment, these cartridges are a trusted solution for research labs involved in antibody production, validation, and downstream analysis.

Application: Protein Assays & Analysis, chromatography
Storage Temperature: 2-8°C
Product Type: Molecular Biology Reagent
Product Brand: Thermo Fisher Scientific™
Product Grade: Molecular Biology

Thermo Scientific™ Pierce™ Protein A Chromatography Cartridges are ready-to-use, pre-packed affinity columns designed for efficient purification of IgG antibodies from serum, ascites fluid, and cell culture supernatants. These cartridges are pre-filled with Protein A Plus Agarose, a high-capacity resin that combines native Protein A with crosslinked 6% beaded agarose (CL-6B) for high-yield and high-purity antibody recovery.

Engineered for both manual and automated workflows, these cartridges are compatible with syringes, peristaltic pumps, and major FPLC/ÄKTA™ systems. Each cartridge includes a connection accessory pack for Luer-Lok or 1/16” tubing fittings.

Key Features & Benefits

  • Pre-Packed, Ready-to-Use Cartridges
    Simplify your antibody purification workflow with high-reproducibility and reduced setup time.
  • High Binding Capacity
    Binds >34 mg human IgG/mL resin; ideal for purifying large antibody quantities.
  • Stable & Reusable Resin
    Low leaching, covalent ligand attachment ensures stability through multiple purification cycles.
  • Versatile Species Compatibility
    Binds strongly to human, rabbit, pig, dog, and cat IgG subclasses. Moderate to weak binding to some mouse IgG subclasses (not recommended for IgG1).
  • AminoLink™ Coupling Chemistry
    Provides stable amide bond linkage between Protein A and agarose beads; minimizes nonspecific binding.
  • Flexible Integration
    Directly connects to chromatography systems or syringes without additional hardware.

Resin & Cartridge Specifications

FeatureDetails
Stationary PhaseProtein A Plus Agarose
Resin BaseCrosslinked 6% beaded agarose (CL-6B)
Protein A SourceNative (Staphylococcus aureus-derived)
Ligand Immobilization MethodAminoLink Coupling Chemistry (amide bonds)
Binding Capacity>34 mg/mL (Human IgG)
Column FormatCartridges: 1 mL or 5 mL
CompatibilitySyringe, FPLC, ÄKTA™, peristaltic pump
ReusabilityYes – regenerable
Storage Conditions4°C to 8°C, do not freeze

Applications

  • Antibody Purification
    • Polyclonal and monoclonal IgG from serum, ascites, and hybridoma culture media
  • Protein A Affinity Capture
    • Efficient recovery of Fc-region binding IgG subclasses
  • Small- to Mid-Scale Chromatography
    • Suitable for laboratory-scale and pilot-scale purifications
  • Immunology & Proteomics Workflows
    • Downstream use in ELISA, Western blot, conjugation, and labeling


Thermo Scientific™ Pierce™ Protein A Chromatography Cartridges deliver high-efficiency IgG purification with a format that suits both automated systems and manual benchwork. Backed by high-binding-capacity resin, low nonspecific binding, and stable ligand attachment, these cartridges are a trusted solution for research labs involved in antibody production, validation, and downstream analysis.

User Guide: Pierce Chromatography Cartridges Protein A
This will display Shipping & Return.

Thermo Scientific™ Pierce™ Protein A Chromatography Cartridges are ready-to-use, pre-packed affinity columns designed for efficient purification of IgG antibodies from serum, ascites fluid, and cell culture supernatants. These cartridges are pre-filled with Protein A Plus Agarose, a high-capacity resin that combines native Protein A with crosslinked 6% beaded agarose (CL-6B) for high-yield and high-purity antibody recovery.

Engineered for both manual and automated workflows, these cartridges are compatible with syringes, peristaltic pumps, and major FPLC/ÄKTA™ systems. Each cartridge includes a connection accessory pack for Luer-Lok or 1/16” tubing fittings.

Key Features & Benefits

  • Pre-Packed, Ready-to-Use Cartridges
    Simplify your antibody purification workflow with high-reproducibility and reduced setup time.
  • High Binding Capacity
    Binds >34 mg human IgG/mL resin; ideal for purifying large antibody quantities.
  • Stable & Reusable Resin
    Low leaching, covalent ligand attachment ensures stability through multiple purification cycles.
  • Versatile Species Compatibility
    Binds strongly to human, rabbit, pig, dog, and cat IgG subclasses. Moderate to weak binding to some mouse IgG subclasses (not recommended for IgG1).
  • AminoLink™ Coupling Chemistry
    Provides stable amide bond linkage between Protein A and agarose beads; minimizes nonspecific binding.
  • Flexible Integration
    Directly connects to chromatography systems or syringes without additional hardware.

Resin & Cartridge Specifications

FeatureDetails
Stationary PhaseProtein A Plus Agarose
Resin BaseCrosslinked 6% beaded agarose (CL-6B)
Protein A SourceNative (Staphylococcus aureus-derived)
Ligand Immobilization MethodAminoLink Coupling Chemistry (amide bonds)
Binding Capacity>34 mg/mL (Human IgG)
Column FormatCartridges: 1 mL or 5 mL
CompatibilitySyringe, FPLC, ÄKTA™, peristaltic pump
ReusabilityYes – regenerable
Storage Conditions4°C to 8°C, do not freeze

Applications

  • Antibody Purification
    • Polyclonal and monoclonal IgG from serum, ascites, and hybridoma culture media
  • Protein A Affinity Capture
    • Efficient recovery of Fc-region binding IgG subclasses
  • Small- to Mid-Scale Chromatography
    • Suitable for laboratory-scale and pilot-scale purifications
  • Immunology & Proteomics Workflows
    • Downstream use in ELISA, Western blot, conjugation, and labeling


Thermo Scientific™ Pierce™ Protein A Chromatography Cartridges deliver high-efficiency IgG purification with a format that suits both automated systems and manual benchwork. Backed by high-binding-capacity resin, low nonspecific binding, and stable ligand attachment, these cartridges are a trusted solution for research labs involved in antibody production, validation, and downstream analysis.

User Guide: Pierce Chromatography Cartridges Protein A

This will display Shipping & Return.

Specifications

Pack Size 2 cartridges x 1 mL, 1 cartridge x 5 mL