The Liofilchem™ MTS™ Meropenem/Meropenem+Phenylboronic Acid (MRP/MBO) MIC Test Strips are specifically designed to detect Klebsiella pneumoniae carbapenemase (KPC) and other beta-lactamase activities in Gram-negative bacteria. These test strips combine the power of gradient diffusion MIC testing with the addition of Phenylboronic Acid (PBA), a potent inhibitor of Class A carbapenemases (e.g., KPC), enabling reliable identification of carbapenem-resistant pathogens.
Key Features
- Dual Testing Capability:
- Each strip includes a gradient for Meropenem (MRP) and Meropenem + Phenylboronic Acid (MBO) for direct MIC comparison.
- Carbapenemase Detection:
- Identifies resistance mechanisms by comparing the MIC values of MRP and MBO, with significant reduction in MIC indicative of KPC production.
- Broad MIC Range:
- Covers 0.125–8 µg/mL for Meropenem and 0.032–2 µg/mL for Meropenem+PBA, allowing for low- and high-level resistance detection.
- High Sensitivity:
- Effectively identifies Class A carbapenemase-producing Enterobacterales with minimal false positives.
- Ease of Use:
- Simple application on agar plates, requiring minimal technical expertise.
- Standards Compliance:
- Conforms to CLSI and EUCAST guidelines for antimicrobial susceptibility testing (AST).
Applications
Application | Description |
---|
Clinical Diagnostics | Differentiates carbapenem resistance due to KPC production in Gram-negative bacteria. |
Antimicrobial Resistance Studies | Tracks the prevalence and emergence of KPC-producing pathogens in healthcare settings. |
Pharmaceutical Research | Evaluates the efficacy of carbapenems and beta-lactamase inhibitors. |
Testing Procedure
- Preparation:
- Prepare a bacterial suspension to 0.5 McFarland standard.
- Spread the suspension uniformly on Mueller-Hinton agar plates.
- Application:
- Place the MTS™ MRP/MBO strips on the inoculated agar surface using sterile forceps.
- Incubation:
- Incubate plates at 35–37°C for 16–20 hours under aerobic conditions.
- Interpretation:
- Read the MIC value where bacterial growth intersects the strip.
- Compare MIC values for Meropenem (MRP) and Meropenem+PBA (MBO):
- A reduction in MIC by ≥3 two-fold dilutions (≥8×) indicates KPC production.
Storage and Stability
Condition | Temperature | Duration |
---|
Long-Term Storage | -20°C | Until expiration date |
Short-Term Storage | 2–8°C | Up to 2 weeks |
During Use | Room Temperature | Immediate use only |
Technical Specifications
Feature | Details |
---|
Active Components | Meropenem and Phenylboronic Acid |
MIC Range | MRP: 0.125–8 µg/mL; MBO: 0.032–2 µg/mL |
Test Method | Gradient diffusion |
Compatible Media | Mueller-Hinton agar |
Incubation Conditions | 35–37°C for 16–20 hours |
Target Pathogens | Gram-negative bacteria, including KPC producers |
Shelf Life | As per expiration date on packaging |
Pack Sizes | 10 or 30 or 100 test strips per pack |
Quality Control Data
Control Organism | Expected Results |
---|
Escherichia coli ATCC® 25922 | MRP MIC: 0.008–0.06 µg/mL; MBO MIC: Similar |
Pseudomonas aeruginosa ATCC® 27853 | MRP MIC: 0.5–4 µg/mL; MBO MIC: No significant reduction |
Klebsiella pneumoniae (KPC-positive strain) | MRP MIC: High (≥8 µg/mL); MBO MIC: Significant reduction |
Staphylococcus aureus ATCC® 29213 | Not applicable (Gram-positive control) |
- Positive Controls: Confirm detection of KPC-producing strains.
- Negative Controls: Ensure no false-positive results in non-KPC producers.
Interpretation of Results
MIC Value Comparison | Interpretation |
---|
MRP MIC = MBO MIC | Absence of KPC production. |
MRP MIC ≥8× MBO MIC | Presence of KPC-producing bacteria. |
Comparison with Other MIC Test Strips
Test Strip | MIC Range (µg/mL) | Recommended Use |
---|
Meropenem/Meropenem+PBA (MRP/MBO) | MRP: 0.125–8; MBO: 0.032–2 | Detection of KPC-producing Enterobacterales. |
Meropenem/Meropenem+EDTA (MRP/MRD) | MRP: 0.125–8; MRD: 0.032–2 | Detection of MBL-producing bacteria. |
Meropenem 0.016–256 | 0.016–256 | General carbapenem susceptibility testing. |
Advantages
Feature | Benefit |
---|
Dual Testing System | Identifies carbapenem resistance due to KPC production. |
High Sensitivity and Specificity | Reduces false-positive and false-negative results. |
Ease of Use | Simplified setup minimizes errors and time. |
Standards Compliance | Adheres to global antimicrobial susceptibility testing guidelines. |
Conclusion
The Liofilchem™ MTS™ Meropenem/Meropenem+PBA (MRP/MBO) MIC Test Strips are a critical tool for identifying KPC carbapenemase production, providing clinicians and researchers with precise and reproducible results. Their dual gradient diffusion system ensures reliable detection of resistance mechanisms, making them indispensable for antimicrobial stewardship and resistance monitoring programs.
https://www.labmartgh.com/shop/product/liofilchem-tm-mts-tm-meropenem-meropenem-phenylboronic-acid-mrp-mbo-0-125-8-0-032-2-mic-test-strips-28423
-
Pack Size:
100/pk
10/pk
30/pk