Liofilchem™ MTS™ Meropenem/Meropenem+Phenylboronic acid MRP/MBO 0.125-8/0.032-2, MIC Test strips

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Conditions générales
Garantie satisfait ou remboursé de 30 jours
Expédition : 2-3 jours ouvrables

  • Pack Size

This combination does not exist.

Place Inquiry

This combination does not exist.

Specifications:
Application Clinical microbiology
Storage Temperature -20°C
Product Type MIC Strips
Product Brand Liofilchem
Product Grade Microbiology grade

The Liofilchem™ MTS™ Meropenem/Meropenem+Phenylboronic Acid (MRP/MBO) MIC Test Strips are specifically designed to detect Klebsiella pneumoniae carbapenemase (KPC) and other beta-lactamase activities in Gram-negative bacteria. These test strips combine the power of gradient diffusion MIC testing with the addition of Phenylboronic Acid (PBA), a potent inhibitor of Class A carbapenemases (e.g., KPC), enabling reliable identification of carbapenem-resistant pathogens.

Key Features

  1. Dual Testing Capability:
    • Each strip includes a gradient for Meropenem (MRP) and Meropenem + Phenylboronic Acid (MBO) for direct MIC comparison.
  2. Carbapenemase Detection:
    • Identifies resistance mechanisms by comparing the MIC values of MRP and MBO, with significant reduction in MIC indicative of KPC production.
  3. Broad MIC Range:
    • Covers 0.125–8 µg/mL for Meropenem and 0.032–2 µg/mL for Meropenem+PBA, allowing for low- and high-level resistance detection.
  4. High Sensitivity:
    • Effectively identifies Class A carbapenemase-producing Enterobacterales with minimal false positives.
  5. Ease of Use:
    • Simple application on agar plates, requiring minimal technical expertise.
  6. Standards Compliance:
    • Conforms to CLSI and EUCAST guidelines for antimicrobial susceptibility testing (AST).

Applications

ApplicationDescription
Clinical DiagnosticsDifferentiates carbapenem resistance due to KPC production in Gram-negative bacteria.
Antimicrobial Resistance StudiesTracks the prevalence and emergence of KPC-producing pathogens in healthcare settings.
Pharmaceutical ResearchEvaluates the efficacy of carbapenems and beta-lactamase inhibitors.

Testing Procedure

  1. Preparation:
    • Prepare a bacterial suspension to 0.5 McFarland standard.
    • Spread the suspension uniformly on Mueller-Hinton agar plates.
  2. Application:
    • Place the MTS™ MRP/MBO strips on the inoculated agar surface using sterile forceps.
  3. Incubation:
    • Incubate plates at 35–37°C for 16–20 hours under aerobic conditions.
  4. Interpretation:
    • Read the MIC value where bacterial growth intersects the strip.
    • Compare MIC values for Meropenem (MRP) and Meropenem+PBA (MBO):
      • A reduction in MIC by ≥3 two-fold dilutions (≥8×) indicates KPC production.

Storage and Stability

ConditionTemperatureDuration
Long-Term Storage-20°CUntil expiration date
Short-Term Storage2–8°CUp to 2 weeks
During UseRoom TemperatureImmediate use only

Technical Specifications

FeatureDetails
Active ComponentsMeropenem and Phenylboronic Acid
MIC RangeMRP: 0.125–8 µg/mL; MBO: 0.032–2 µg/mL
Test MethodGradient diffusion
Compatible MediaMueller-Hinton agar
Incubation Conditions35–37°C for 16–20 hours
Target PathogensGram-negative bacteria, including KPC producers
Shelf LifeAs per expiration date on packaging
Pack Sizes10 or 30 or 100 test strips per pack

Quality Control Data

Control OrganismExpected Results
Escherichia coli ATCC® 25922MRP MIC: 0.008–0.06 µg/mL; MBO MIC: Similar
Pseudomonas aeruginosa ATCC® 27853MRP MIC: 0.5–4 µg/mL; MBO MIC: No significant reduction
Klebsiella pneumoniae (KPC-positive strain)MRP MIC: High (≥8 µg/mL); MBO MIC: Significant reduction
Staphylococcus aureus ATCC® 29213Not applicable (Gram-positive control)
  • Positive Controls: Confirm detection of KPC-producing strains.
  • Negative Controls: Ensure no false-positive results in non-KPC producers.

Interpretation of Results

MIC Value ComparisonInterpretation
MRP MIC = MBO MICAbsence of KPC production.
MRP MIC ≥8× MBO MICPresence of KPC-producing bacteria.

Comparison with Other MIC Test Strips

Test StripMIC Range (µg/mL)Recommended Use
Meropenem/Meropenem+PBA (MRP/MBO)MRP: 0.125–8; MBO: 0.032–2Detection of KPC-producing Enterobacterales.
Meropenem/Meropenem+EDTA (MRP/MRD)MRP: 0.125–8; MRD: 0.032–2Detection of MBL-producing bacteria.
Meropenem 0.016–2560.016–256General carbapenem susceptibility testing.

Advantages

FeatureBenefit
Dual Testing SystemIdentifies carbapenem resistance due to KPC production.
High Sensitivity and SpecificityReduces false-positive and false-negative results.
Ease of UseSimplified setup minimizes errors and time.
Standards ComplianceAdheres to global antimicrobial susceptibility testing guidelines.

Conclusion

The Liofilchem™ MTS™ Meropenem/Meropenem+PBA (MRP/MBO) MIC Test Strips are a critical tool for identifying KPC carbapenemase production, providing clinicians and researchers with precise and reproducible results. Their dual gradient diffusion system ensures reliable detection of resistance mechanisms, making them indispensable for antimicrobial stewardship and resistance monitoring programs.

  • Pack Size:   100/pk 10/pk 30/pk
Resources file not found.


Add a Review

Rate this Product  
Name *
Email *

Your Review *
28423





0

0  Reviews
(0) 
(0) 
(0) 
(0) 
(0) 

Customer Review




Showing 0 Of 0