AMPLIRUN® HHV DNA Control, 100 µl
Catalog No :
CAS Number :
Brand :
In Stock
Concentration: 10,000-20,000 copies/µl
Specifications:
| Application | Quality Control | ||
| Storage Temperature | -20°C | ||
| Product Type | Nucleic acid controls | Forms | Lyophilized DNA |
| Product Brand | VIRCELL | ||
| Product Grade | Molecular Biology | ||
The amplirun® hhv dna controls provide purified, quantified DNA from Human herpesvirus 6 (HHV-6) and Human herpesvirus 8 (HHV-8) for use as positive controls in nucleic acid amplification techniques. Each control contains the complete microbial genome, quantified at 10,000–20,000 copies/µL (qPCR-determined), and is supplied in a lyophilized, non-infectious format.
These controls are universally compatible with PCR, qPCR, and other molecular platforms, offering reliable references for assay validation, quality control, and infectious disease research.
Available Controls
| Product Reference | Description | Class |
|---|---|---|
| MBC025-R | amplirun® hhv-6 dna control | RUO |
| MBC128-R | amplirun® hhv-8 dna control | RUO |
Key Features
- Purified complete genome DNA – available for HHV-6 and HHV-8.
- qPCR quantified – 10,000–20,000 copies/µL.
- Sequencing data available – supports primer and probe design.
- Non-infectious & lyophilized – stable for shipping and storage at ambient temperature.
- Easy reconstitution – resuspend with 100 µL Molecular Biology Grade Water (included).
- Universal compatibility – validated for PCR, qPCR, and other nucleic acid amplification assays.
Applications
- Positive controls for HHV-6 and HHV-8 PCR/qPCR assays.
- Validation of in-house and commercial molecular diagnostic methods.
- Absolute quantification via standard curve generation.
- QC material to ensure assay sensitivity, specificity, and reproducibility.
- Research into opportunistic viral infections (e.g., HHV-6 in immunocompromised patients, HHV-8 in Kaposi’s sarcoma).
Product Details
| Property | Value |
|---|---|
| Concentration | 10,000–20,000 copies/µL |
| Format | Lyophilized DNA |
| Reconstitution | 100 µL Molecular Biology Grade Water |
| Infectivity | Non-infectious |
| Class | RUO – Research Use Only |
| Sequencing Data | HHV-6 Partial Sequence: PP921919 HHV-8 Fragments
|
| Storage | Stable at ambient temperature until reconstituted |
The amplirun® hhv dna controls provide standardized, safe, and reproducible positive controls for molecular detection of HHV-6 and HHV-8. With quantified DNA, sequencing references, and a stable lyophilized format, they are essential tools for diagnostic assay validation, quality control, and research into herpesvirus-associated diseases.
- Serotype: HHV-6 HHV-8
0