PAMAS SBSS Laboratory Particle Counter for Liquids

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Configured Package Content
Base Instrument
PAMAS HCB-LD-50/50 Light Extinction Sensor
K-00001: Calibration per ISO 11171 (Clause 6) using ISO MTD test dust (Size range: 4–70 µm(c))
K-00002: Calibration per ISO 4402 using ACFTD test dust (Size range: 2–100 µm)
L-00001 PAMAS PMA Software (1.00 PC License)
Mo00263 Pump/Air Dryer Unit (110 V)

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application Analytical Chemistry, Petroleum & Fuel Testing Warranty 1 Year
    Storage Temperature Ambient
    Product Type Laboratory Equipment
    Product Brand PAMAS Partikelmess
    Product Grade Analytical grade

    Precision Particle Counting System for Viscous Liquids and Pharmaceutical Applications

    The PAMAS SBSS (Syringe Bottle Sampling System) is a state-of-the-art laboratory particle counting instrument designed for highly accurate contamination analysis of liquids with viscosities up to 1600 cSt. Recognized as a benchmark standard in certified testing laboratories, the PAMAS SBSS provides fully automated sample processing for high-precision, reproducible results—ideal for industrial oils, fuels, and pharmaceutical injectables.

    Key Features

    • Automated Batch Sampling: Supports programmable sample processing including pre-filling, degassing (vacuum), pressurization, and flushing.
    • Precise Volume Control: Integrated stepper-motor-driven syringe module for automatic flow and sample volume regulation.
    • High Repeatability & Sensitivity: Up to 16 freely adjustable size channels (expandable to 32).
    • Custom Vessel Compatibility: Accepts sample bottles with up to 7 cm diameter and 18 cm height.
    • Pressure Sampling: Up to 10 bar; ideal for volatile or pressurized liquids.
    • Sample Degassing: Optional vacuum cycle removes air bubbles for enhanced measurement integrity.
    • Flexible Measuring Volume: From 1 mL to 1000 mL.

    Sensor Options & Detection Capabilities

    Sensor ModelSize RangesMax Particle ConcentrationStandard Compliance
    PAMAS HCB-LD-50/501–200 µm (ISO 21501-3) / 1–400 µm (optional) / 1–100 µm (ISO 4402) / 4–70 µm(c) (ISO 11171)24,000 P/mL @ 25 mL/minISO 21501-3, ISO 4402, ISO 11171
    PAMAS HCB-LD-25/25Same as above (except no 1–400 µm option)120,000 P/mL @ 25 mL/minISO 21501-3, ISO 4402, ISO 11171
    PAMAS SLS-25/250.5–20 µm (ISO 21501-2) / 1–20 µm (ISO 4402) / 1.5–25 µm(c) (ISO 11171)13,000 P/mL @ 10 mL/minISO 21501-2, ISO 4402, ISO 11171

    Compatible Applications

    • Industrial Oils: Hydraulic, turbine, gear, engine, and phosphate ester fluids
    • Water-Based Fluids: Glycol-based or synthetic lubricants
    • Fuels: Diesel, gasoline, aviation fuel
    • Pharmaceuticals: Parenteral drugs, protein solutions (USP <787>, <788>, <789>)
    • Volatile Fluids: Fluids sensitive to air or pressure
    • Biotech Samples: Protein-based injectables requiring low-volume analysis

    Software Options

    • PAMAS USP Software
      • 21 CFR Part 11 compliant
      • For pharmaceutical-grade testing (e.g., USP <787>, <788>, Ph. Eur. 2.9.19)
    • PAMAS PMA Software
      • For general contamination control
      • Supports standards such as ISO 4406, NAS 1638, SAE AS4059, and many more

    Standard Compliance

    Supports international and industry-specific standards:

    ISO 11171, ISO 4402, ISO 21501-2/3, USP <787>/<788>/<789>, Ph. Eur. 2.9.19, SAE AS4059, NAS 1638, GOST 17216, NAVAIR 01-1A-17, ASTM D7647, and more.

    Package Options

    • Syringe volumes: 1 mL, 10 mL, and 25 mL (interchangeable)
    • Measurement volume range: 1–1000 mL
    • Magnetic Stirrer: Integrated for sample homogenization
    • Backflush Capability: Minimizes cross-contamination and clogging

    Configured Package Content

    This configured PAMAS SBSS system includes the following components:

    Base Instrument

    • PAMAS SBSS Laboratory Particle Counter for batch sampling of liquids up to 1600 cSt viscosity
    • Integrated features: automatic pre-fill, vacuum degassing, pressurization, backflush, and programmable measurement cycles

    Sensor Module

    • PAMAS HCB-LD-50/50 Light Extinction Sensor
      • Sensor orifice: 500 µm × 500 µm
      • Max. particle concentration: 24,000 particles/mL at 7.8% coincidence rate
      • Seal material: Viton

    Calibration Standards

    • K-00001: Calibration per ISO 11171 (Clause 6) using ISO MTD test dust (Size range: 4–70 µm(c))
    • K-00002: Calibration per ISO 4402 using ACFTD test dust (Size range: 2–100 µm)

    Software

    • L-00001 PAMAS PMA Software (1.00 PC License)
      • Particle Measuring & Analysis software for data acquisition, reporting, and cleanliness code evaluation (e.g., ISO 4406, NAS 1638, etc.)
      • Windows-compatible, user-friendly interface

    Accessories

    • Mo00263 Pump/Air Dryer Unit (110 V)
      • Compact vacuum and air drying module
      • Degasses samples and provides clean compressed air up to 5 bar
      • Enhances sampling precision for volatile or sensitive liquids

    The PAMAS SBSS is a versatile and trusted particle counting platform that ensures high accuracy, compliance with global standards, and automated sample handling for laboratories working with oils, fuels, and biological injectables. It is especially suitable for laboratories demanding precise, programmable workflows and regulatory compliance (FDA/Pharmacopoeia).

    Product Specification not found.


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    30671





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review




    Showing 0 Of 0