    Specifications:
    Application Hematology
    Storage Temperature 2-8°C
    Product Type Calibration Standard Forms Liquid
    Product Brand Bio-Rad
    Product Grade Medical grade

    Lyphochek Coagulation Control is an assayed, lyophilized, human-plasma control designed to monitor the precision of routine coagulation tests, including normal and abnormal levels of PT, APTT, Fibrinogen, Antithrombin III and Thrombin Time. The product is provided in lyophilized form for ease of storage and increased stability. Extended open-vial stability helps to reduce the cost of daily QC and offers even more value where QC testing must be performed on every shift.

    The control is available in three levels, which allows for monitoring of test system reliability. The independent Lyphochek Coagulation Control can be used on a variety of systems, including Siemens BCS, Sysmex CA, Diagnostica Stago STA, Instrumentation Laboratory ACL and ELECTRA, and Trinity Biotech AMAX.


    Features

    • Consolidated menu of analytes—Contains multiple analytes for routine coagulation assays, including PT, APTT, Fibrinogen, Antithrombin III and Thrombin Time
    • Patient-like material—Lyophilized, human-plasma control
    • Multiple levels— Trilevel control offers test system reliability monitoring
    • Ease of use—Can be easily stored and offers increased stability
    • Long shelf life—Reduces crossover studies which helps simplify workflow

     

    Storage & Stability

    ConfigurationStabilityShelf lifeLevelsFormat
    1 mL (x12)• 48 hour open-vial stability at 2-25°C
    3 year shelf life at 2-8°C1, 2, 3Standard vial
    1 mL (x3) one of each level• 48 hour open-vial stability at 2-25°C
    3 year shelf life at 2-8°C MiniPakStandard vial

     

    Analytes

    • Activated Partial Thromboplastin Time (APTT)
    • Antithrombin III (AT III)
    • Fibrinogen
    • Prothrombin Time (PT)
    • Thrombin Time (TT)

    Application & Use

    This product should be treated the same as patient specimens and used in accordance with the instructions accompanying the instrument, kit or reagent.

    Using a volumetric pipette or equivalent, reconstitute each vial with 1.0 mL of distilled or deionized water. Replace the stopper and allow this product to stand for approximately 10 to 15 minutes swirling occasionally. Before sampling, gently swirl the vial several times to ensure homogeneity. After each use, promptly replace the stopper and return to the appropriate storage condition.

    If the reconstituted product has been stored frozen, allow it to reach room temperature (18°C to 25°C) before use. Before sampling, gently swirl the vial several times.