Thermo Scientific™ Applied Biosystems™ MicroAmp™ 8-Cap Strip, Dome shaped, clear
Catalog No :
CAS Number :
Brand :
In Stock
Specifications:
Application | qPCR |
Material | Polypropylene |
Storage Temperature | Ambient |
Product Type | Real Time PCR Plastics |
Product Brand | Thermo Fisher Scientific™ |
Product Grade | Molecular Biology |
Applied Biosystems™ MicroAmp™ 8-Cap Strips are designed for secure sealing of MicroAmp™ PCR tubes, strip tubes, and 96-well plates. These high-quality polypropylene domed caps provide a tight seal to minimize sample evaporation and contamination, ensuring reliable PCR and qPCR performance.
They are compatible with 0.2 mL individual tubes, strip tubes (0.1 or 0.2 mL), and 48- or 96-well plates, making them ideal for high-throughput PCR, endpoint PCR, and DNA amplification workflows.
For real-time PCR applications, the MicroAmp™ Optical 8-Cap Strips (Cat. No. 4323032) with a flat-top profile are recommended to ensure optical clarity and fluorescence signal detection.
Key Features & Benefits
- Tight-Sealing Caps to Prevent Evaporation & Contamination
- Maintains sample integrity during PCR thermal cycling.
- Provides a reliable seal to minimize evaporation and cross-contamination.
- Domed Profile for Enhanced Performance in Endpoint PCR
- Suitable for conventional PCR assays and gel electrophoresis analysis.
- Improves thermal sealing while preventing condensation buildup.
- Compatible with Various MicroAmp™ Reaction Tubes & Plates
- Fits 0.2 mL individual PCR tubes, 8-strip tubes, and 96-well plates.
- Ensures seamless integration with Applied Biosystems™ thermal cyclers.
- Easy Application & Removal
- Designed to be used with the MicroAmp™ Cap Installing Tool for quick sealing.
- Easily removed using the built-in tabs at the end of each strip.
- Certified DNA/RNase-Free for Contamination-Free PCR
- Prevents sample degradation and ensures reliable molecular biology results.
- Suitable for sensitive PCR applications, including genotyping, sequencing, and forensics.
Product Specifications
Feature | Details |
---|---|
Product Name | Applied Biosystems™ MicroAmp™ 8-Cap Strip |
Catalog Number | N8011535 (1,500 Strips) / N8010535 (300 Strips) |
Cap Type | Domed |
Material | Polypropylene |
Color | Natural (Clear) |
Format | 8-Strip Caps |
For Use With | 0.2 mL PCR Tubes, Strip Tubes, 48- and 96-Well Plates |
Sterility | Certified DNA/RNase-Free |
Closure Type | Snap-on, Secure Seal |
Shipping Condition | Room Temperature |
Storage Condition | Room Temperature |
Use Cases & Applications
1. Polymerase Chain Reaction (PCR) & Quantitative PCR (qPCR)
- Ensures Secure Sealing During Thermal Cycling
- Prevents sample evaporation and cross-contamination.
- Compatible with high-throughput PCR workflows.
- Supports Endpoint PCR & Gel Electrophoresis Analysis
- Domed cap design allows efficient condensation control.
- Ideal for genotyping, sequencing, and DNA amplification assays.
2. Real-Time PCR & Fluorescence-Based Detection
- Compatible with MicroAmp™ PCR Strip Tubes & 96-Well Plates
- Works well with Applied Biosystems™ real-time PCR systems.
- Provides consistent fluorescence signal detection in qPCR assays.
- Alternative Option for qPCR Optical Caps
- For qPCR fluorescence-based assays, use MicroAmp™ Optical 8-Cap Strips (4323032) for optimal signal clarity.
3. Molecular Biology & DNA/RNA Research
- Securely Seals Nucleic Acid Samples for Amplification
- Ideal for RT-PCR, cDNA synthesis, and pathogen detection assays.
- Prevents sample degradation and contamination during sensitive workflows.
- Supports Microbial & Viral DNA/RNA Testing
- Used in forensic, diagnostic, and clinical molecular assays.
- Ensures high reproducibility and assay reliability.
4. Genomics & Biotechnological Research
- Facilitates High-Throughput Genotyping & SNP Analysis
- Ensures efficient processing of multiple samples in parallel.
- Provides secure sample handling in automated workflows.
- Enhances Sample Processing in Next-Generation Sequencing (NGS) Workflows
- Reliable for pre-PCR sample amplification and DNA library preparation.
- Facilitates targeted sequencing workflows with high reproducibility.
Usage & Handling Instructions
Cap Installation & Sample Preparation
- Place PCR Tubes or Plates in the Thermal Cycler Block
- Ensure that all reaction tubes are properly positioned for uniform heating.
- Seal with MicroAmp™ 8-Cap Strips
- Use the MicroAmp™ Cap Installing Tool to apply even pressure and form a secure seal.
- Ensure caps are tightly closed to prevent evaporation during PCR cycling.
- Run the Thermal Cycling Program
- Use the recommended PCR/qPCR conditions for accurate and reproducible amplification.
- Post-PCR Sample Handling & Analysis
- Remove caps using the built-in tabs for easy opening.
- Proceed with gel electrophoresis, qPCR analysis, or sequencing workflows.
Storage & Handling Instructions
- Storage Conditions:
- Store at room temperature in a dry, contamination-free environment.
- Keep caps sealed in the original packaging until use.
- Handling Precautions:
- Use gloves and aseptic techniques to prevent contamination.
- Ensure proper sealing of caps to prevent sample loss.
- Disposal Guidelines:
- Dispose of used cap strips as per biosafety and laboratory waste regulations.
- If used with biohazardous materials, autoclave before disposal.
Why Choose Applied Biosystems™ MicroAmp™ 8-Cap Strips?
✅ Designed for PCR, qPCR, and molecular biology workflows
✅ Domed profile minimizes evaporation & prevents contamination
✅ Certified DNA/RNase-free for contamination-free amplification
✅ Compatible with 0.2 mL PCR tubes, strip tubes, and 96-well plates
✅ Easy-to-apply and remove, with optional cap installation tool
Applied Biosystems™ MicroAmp™ 8-Cap Strips are a reliable choice for secure and precise sample sealing, ensuring consistent amplification and contamination-free PCR and qPCR workflows.
- Pack Size: 300 Strips 1500 Strips