Skip to Content
Books & Reference Materials
Category Image
Extraction Systems
Category Image
Industrial Instruments
Category Image
Glassware & Plasticware
Category Image
Transfection & Cloning
Category Image
Laboratory Quality Control Solutions
Category Image
Entomology Supplies
Category Image
Sample Preparation
Category Image

Liofilchem™ MTS™ Levofloxacin LEV 0.002-32, MIC Test strips

(0 review)
SKU: 920810
Brand: Liofilchem
UoM: Each
Inquiry Required

  • Pack Size
Store Availability & Pickup
LabMart Limited - Tamale
NS-246, Via, 4388 Tamale-Kumbungu Rd, Tamale, Northern Region, Ghana
Not available
LabMart Limited - Accra
10 Rcecourse street, Accra, Greater Accra Region, Ghana
Not available
Add to quote
MOQ : 1.0 Each
Estimated delivery Estimated delivery: 4-8 weeks
Telecel AirtelTigo Maestro Mastercard Visa MTN

The Liofilchem™ MTS™ Levofloxacin LEV MIC Test Strips are advanced diagnostic tools for determining the Minimum Inhibitory Concentration (MIC) of Levofloxacin, a fluoroquinolone antibiotic. Designed for precision and ease of use, these strips are ideal for clinical diagnostics and antimicrobial resistance testing. They provide accurate MIC values for a wide range of bacterial pathogens, supporting effective treatment decisions and research in antimicrobial resistance.

Key Features

1. Gradient Diffusion Technology

  • The strips feature a stable gradient of Levofloxacin ranging from 0.002 to 32 μg/mL, enabling precise MIC determination.
  • Eliminates the need for complex broth dilution methods.

2. High Sensitivity and Specificity

  • Accurately detects Levofloxacin susceptibility in both Gram-positive and Gram-negative bacteria, including multidrug-resistant strains.
  • Effective for pathogens causing respiratory, urinary, and systemic infections.

3. Broad Compatibility

  • Designed for use with routine diagnostic procedures.
  • Fully compliant with international standards like EUCAST, CLSI, and ISO guidelines.

4. Visual MIC Interpretation

  • Provides a clear MIC endpoint at the intersection of the bacterial growth ellipse and the strip’s gradient scale.

5. Rapid Results

  • Generates results within 16–24 hours of incubation, ensuring timely treatment decisions.

6. Reliable and Durable

  • Manufactured under stringent quality control for consistent performance and stability when stored at -20°C.

Applications

1. Clinical Diagnostics

  • Determine bacterial susceptibility to Levofloxacin in infections caused by pathogens such as:
    • Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Staphylococcus aureus, and Streptococcus pneumoniae.

2. Resistance Surveillance

  • Monitor resistance trends in fluoroquinolone antibiotics in healthcare settings.

3. Research and Development

  • Evaluate the efficacy of Levofloxacin in laboratory studies or clinical trials.

4. Infection Control

  • Identify multidrug-resistant pathogens in hospital environments to guide infection control strategies.

How It Works

  1. Sample Preparation:
    • Standardize a bacterial suspension to the appropriate McFarland standard (e.g., 0.5 McFarland).
  2. Application:
    • Spread the bacterial suspension evenly onto an agar plate.
    • Place the MTS Levofloxacin strip on the inoculated plate.
  3. Incubation:
    • Incubate the plate at 35–37°C for 16–24 hours.
  4. Result Interpretation:
    • Measure the MIC value at the point where the ellipse of inhibition intersects the strip’s gradient.

Specifications

ParameterDetails
AntibioticLevofloxacin (LEV)
MIC Range0.002–32 μg/mL
Target OrganismsGram-negative and Gram-positive bacteria
Incubation Time16–24 hours
Storage Conditions2–8°C / -20°C
Standards ComplianceEUCAST, CLSI

Advantages

1. Precision

  • Provides highly accurate MIC results using advanced gradient diffusion technology.

2. Efficiency

  • Saves time compared to traditional methods, delivering actionable results quickly.

3. Versatility

  • Effective for testing a wide spectrum of bacterial species and resistance levels.

4. Reproducibility

  • Consistent results across multiple tests, ensuring reliability for clinical and research applications.

Limitations

  • May require additional molecular or confirmatory tests for identifying specific resistance mechanisms.
  • Not suitable for organisms that do not grow well on standard media.

Why Choose Liofilchem™ MTS™ Levofloxacin LEV?

  • Accurate: Delivers precise MIC results for clinical and research needs.
  • Fast: Reduces turnaround time for susceptibility testing.
  • Compliant: Adheres to international standards for consistent and reliable testing.

The Liofilchem™ MTS™ Levofloxacin LEV MIC Test Strips are indispensable for laboratories aiming to conduct accurate, efficient, and standardized antimicrobial susceptibility testing.

Application: Clinical microbiology
Storage Temperature: -20°C
Product Type: MIC Strips
Product Brand: Liofilchem
Product Grade: Microbiology grade

The Liofilchem™ MTS™ Levofloxacin LEV MIC Test Strips are advanced diagnostic tools for determining the Minimum Inhibitory Concentration (MIC) of Levofloxacin, a fluoroquinolone antibiotic. Designed for precision and ease of use, these strips are ideal for clinical diagnostics and antimicrobial resistance testing. They provide accurate MIC values for a wide range of bacterial pathogens, supporting effective treatment decisions and research in antimicrobial resistance.

Key Features

1. Gradient Diffusion Technology

  • The strips feature a stable gradient of Levofloxacin ranging from 0.002 to 32 μg/mL, enabling precise MIC determination.
  • Eliminates the need for complex broth dilution methods.

2. High Sensitivity and Specificity

  • Accurately detects Levofloxacin susceptibility in both Gram-positive and Gram-negative bacteria, including multidrug-resistant strains.
  • Effective for pathogens causing respiratory, urinary, and systemic infections.

3. Broad Compatibility

  • Designed for use with routine diagnostic procedures.
  • Fully compliant with international standards like EUCAST, CLSI, and ISO guidelines.

4. Visual MIC Interpretation

  • Provides a clear MIC endpoint at the intersection of the bacterial growth ellipse and the strip’s gradient scale.

5. Rapid Results

  • Generates results within 16–24 hours of incubation, ensuring timely treatment decisions.

6. Reliable and Durable

  • Manufactured under stringent quality control for consistent performance and stability when stored at -20°C.

Applications

1. Clinical Diagnostics

  • Determine bacterial susceptibility to Levofloxacin in infections caused by pathogens such as:
    • Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Staphylococcus aureus, and Streptococcus pneumoniae.

2. Resistance Surveillance

  • Monitor resistance trends in fluoroquinolone antibiotics in healthcare settings.

3. Research and Development

  • Evaluate the efficacy of Levofloxacin in laboratory studies or clinical trials.

4. Infection Control

  • Identify multidrug-resistant pathogens in hospital environments to guide infection control strategies.

How It Works

  1. Sample Preparation:
    • Standardize a bacterial suspension to the appropriate McFarland standard (e.g., 0.5 McFarland).
  2. Application:
    • Spread the bacterial suspension evenly onto an agar plate.
    • Place the MTS Levofloxacin strip on the inoculated plate.
  3. Incubation:
    • Incubate the plate at 35–37°C for 16–24 hours.
  4. Result Interpretation:
    • Measure the MIC value at the point where the ellipse of inhibition intersects the strip’s gradient.

Specifications

ParameterDetails
AntibioticLevofloxacin (LEV)
MIC Range0.002–32 μg/mL
Target OrganismsGram-negative and Gram-positive bacteria
Incubation Time16–24 hours
Storage Conditions2–8°C / -20°C
Standards ComplianceEUCAST, CLSI

Advantages

1. Precision

  • Provides highly accurate MIC results using advanced gradient diffusion technology.

2. Efficiency

  • Saves time compared to traditional methods, delivering actionable results quickly.

3. Versatility

  • Effective for testing a wide spectrum of bacterial species and resistance levels.

4. Reproducibility

  • Consistent results across multiple tests, ensuring reliability for clinical and research applications.

Limitations

  • May require additional molecular or confirmatory tests for identifying specific resistance mechanisms.
  • Not suitable for organisms that do not grow well on standard media.

Why Choose Liofilchem™ MTS™ Levofloxacin LEV?

  • Accurate: Delivers precise MIC results for clinical and research needs.
  • Fast: Reduces turnaround time for susceptibility testing.
  • Compliant: Adheres to international standards for consistent and reliable testing.

The Liofilchem™ MTS™ Levofloxacin LEV MIC Test Strips are indispensable for laboratories aiming to conduct accurate, efficient, and standardized antimicrobial susceptibility testing.

No resources are currently available for this product.

This will display Shipping & Return.

The Liofilchem™ MTS™ Levofloxacin LEV MIC Test Strips are advanced diagnostic tools for determining the Minimum Inhibitory Concentration (MIC) of Levofloxacin, a fluoroquinolone antibiotic. Designed for precision and ease of use, these strips are ideal for clinical diagnostics and antimicrobial resistance testing. They provide accurate MIC values for a wide range of bacterial pathogens, supporting effective treatment decisions and research in antimicrobial resistance.

Key Features

1. Gradient Diffusion Technology

  • The strips feature a stable gradient of Levofloxacin ranging from 0.002 to 32 μg/mL, enabling precise MIC determination.
  • Eliminates the need for complex broth dilution methods.

2. High Sensitivity and Specificity

  • Accurately detects Levofloxacin susceptibility in both Gram-positive and Gram-negative bacteria, including multidrug-resistant strains.
  • Effective for pathogens causing respiratory, urinary, and systemic infections.

3. Broad Compatibility

  • Designed for use with routine diagnostic procedures.
  • Fully compliant with international standards like EUCAST, CLSI, and ISO guidelines.

4. Visual MIC Interpretation

  • Provides a clear MIC endpoint at the intersection of the bacterial growth ellipse and the strip’s gradient scale.

5. Rapid Results

  • Generates results within 16–24 hours of incubation, ensuring timely treatment decisions.

6. Reliable and Durable

  • Manufactured under stringent quality control for consistent performance and stability when stored at -20°C.

Applications

1. Clinical Diagnostics

  • Determine bacterial susceptibility to Levofloxacin in infections caused by pathogens such as:
    • Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Staphylococcus aureus, and Streptococcus pneumoniae.

2. Resistance Surveillance

  • Monitor resistance trends in fluoroquinolone antibiotics in healthcare settings.

3. Research and Development

  • Evaluate the efficacy of Levofloxacin in laboratory studies or clinical trials.

4. Infection Control

  • Identify multidrug-resistant pathogens in hospital environments to guide infection control strategies.

How It Works

  1. Sample Preparation:
    • Standardize a bacterial suspension to the appropriate McFarland standard (e.g., 0.5 McFarland).
  2. Application:
    • Spread the bacterial suspension evenly onto an agar plate.
    • Place the MTS Levofloxacin strip on the inoculated plate.
  3. Incubation:
    • Incubate the plate at 35–37°C for 16–24 hours.
  4. Result Interpretation:
    • Measure the MIC value at the point where the ellipse of inhibition intersects the strip’s gradient.

Specifications

ParameterDetails
AntibioticLevofloxacin (LEV)
MIC Range0.002–32 μg/mL
Target OrganismsGram-negative and Gram-positive bacteria
Incubation Time16–24 hours
Storage Conditions2–8°C / -20°C
Standards ComplianceEUCAST, CLSI

Advantages

1. Precision

  • Provides highly accurate MIC results using advanced gradient diffusion technology.

2. Efficiency

  • Saves time compared to traditional methods, delivering actionable results quickly.

3. Versatility

  • Effective for testing a wide spectrum of bacterial species and resistance levels.

4. Reproducibility

  • Consistent results across multiple tests, ensuring reliability for clinical and research applications.

Limitations

  • May require additional molecular or confirmatory tests for identifying specific resistance mechanisms.
  • Not suitable for organisms that do not grow well on standard media.

Why Choose Liofilchem™ MTS™ Levofloxacin LEV?

  • Accurate: Delivers precise MIC results for clinical and research needs.
  • Fast: Reduces turnaround time for susceptibility testing.
  • Compliant: Adheres to international standards for consistent and reliable testing.

The Liofilchem™ MTS™ Levofloxacin LEV MIC Test Strips are indispensable for laboratories aiming to conduct accurate, efficient, and standardized antimicrobial susceptibility testing.

No resources are currently available for this product.

This will display Shipping & Return.

Specifications

Pack Size 100/pk, 10/pk, 30/pk