Skip to Content
Books & Reference Materials
Category Image
Extraction Systems
Category Image
Industrial Instruments
Category Image
Glassware & Plasticware
Category Image
Transfection & Cloning
Category Image
Laboratory Quality Control Solutions
Category Image
Entomology Supplies
Category Image
Sample Preparation
Category Image

Liofilchem® Ceftaroline CPT, Antimicrobial Susceptibility Discs, 30 µg

(0 review)
SKU: 9198
Brand: Liofilchem
UoM: 250/pk
400.00 GH¢ 400.00 GH¢

Store Availability & Pickup
LabMart Limited - Tamale
NS-246, Via, 4388 Tamale-Kumbungu Rd, Tamale, Northern Region, Ghana
Not available
LabMart Limited
10 Rcecourse street, Accra, Greater Accra Region, Ghana
16 available
Add to cart
MOQ : 1.0 250/pk
Estimated delivery Estimated delivery: 3-5 business days
Telecel AirtelTigo Maestro Mastercard Visa MTN

The Liofilchem® Ceftaroline (CPT) Antimicrobial Susceptibility Discs, 30 µg are designed for in vitro disc diffusion testing to determine the susceptibility of bacteria to ceftaroline, a fifth-generation cephalosporin. Ceftaroline is active against a range of Gram-positive and some Gram-negative organisms and is notable for its effectiveness against methicillin-resistant Staphylococcus aureus (MRSA).

Each disc contains 30 µg of ceftaroline, formulated according to CLSI and EUCAST standards, and is used in standardized antimicrobial susceptibility testing procedures using Mueller-Hinton agar.

These discs are widely used in clinical microbiology laboratories, hospital infection control, research, and antimicrobial surveillance programs, especially when testing for multidrug-resistant pathogens.

Key Features

  • High-quality 30 µg potency per disc, meeting international AST standards.
  • Reliable detection of ceftaroline susceptibility, especially for MRSA and other multidrug-resistant Gram-positive organisms.
  • Certified manufacturing under ISO 9001 and ISO 13485 quality management systems.
  • Ready-to-use discs individually sealed in aluminum blister packs with desiccant for optimal stability.
  • Compatible with manual and automated disc dispensers and standard AST workflows.

Specifications

AttributeDetails
Antibiotic AgentCeftaroline (CPT)
Potency30 µg
Disc Diameter6 mm
Test MethodKirby-Bauer disc diffusion
Compliant StandardsCLSI M100, EUCAST guidelines
Recommended MediaMueller-Hinton agar (standard or with additives)
Storage Conditions2–8 °C
Shelf Life24 months
Intended UseIn vitro diagnostic use (IVD)

Use Cases

1. Detection of MRSA Susceptibility to Ceftaroline

Ceftaroline is one of the few β-lactams effective against MRSA. These discs are routinely used to assess S. aureus, especially methicillin-resistant strains, for ceftaroline susceptibility to guide therapy in serious infections such as:

  • Bloodstream infections
  • Pneumonia
  • Complicated skin and soft tissue infections

2. Testing of Multidrug-Resistant Streptococci and Gram-negative Isolates

While ceftaroline has primary activity against Gram-positive cocci, it is also tested against select Gram-negative organisms such as Haemophilus influenzae and E. coli, especially in:

  • Respiratory samples
  • Surgical site infections
  • Nosocomial pathogen surveillance

3. Antibiogram Development and Resistance Surveillance

  • Used by microbiology labs to update local antibiograms.
  • Integrated into hospital stewardship programs to monitor resistance trends and inform empirical prescribing policies.

4. Research and Drug Development

Ideal for academic and clinical researchers investigating:

  • Resistance evolution in MRSA
  • Ceftaroline activity across diverse bacterial species
  • Synergy testing with other β-lactams or inhibitors

Testing Procedure

  1. Prepare the Inoculum
    • Prepare a 0.5 McFarland standard suspension of the test organism using sterile saline or broth.
  2. Inoculate the Mueller-Hinton Agar Plate
    • Swab the surface of the agar uniformly with the inoculum using a sterile swab.
  3. Apply the Ceftaroline Disc (30 µg)
    • Place one disc on the agar surface using sterile forceps or a disc dispenser.
    • Ensure discs are firmly in contact with the agar and evenly spaced.
  4. Incubate the Plate
    • Invert and incubate at 35 ± 2 °C for 16–20 hours in ambient air.
    • Use 5% CO₂ for Streptococcus pneumoniae or other fastidious organisms if needed.
  5. Measure and Interpret the Zone of Inhibition
    • Measure the diameter of the zone (in mm) with a ruler or caliper.
    • Compare zone size to CLSI or EUCAST breakpoint tables for interpretation:
      • Susceptible (S)
      • Intermediate (I)
      • Resistant (R)

Interpretation Standards (Reference – Always Check Latest CLSI/EUCAST)

OrganismSusceptible (S)Resistant (R)
Staphylococcus aureus≥ 24 mm (CLSI M100)≤ 21 mm
Streptococcus pneumoniaeRefer to CO₂-based method guidelines

Note: Always consult the current year CLSI or EUCAST documentation for accurate interpretive criteria.

Comparison with Related AST Discs

ProductAgentTarget OrganismsUse
Liofilchem® Ceftaroline (CPT) 30 µgCeftarolineMRSA, MSSA, StreptococciDetect β-lactam susceptibility in MRSA
Liofilchem® Vancomycin 30 µgVancomycinMRSA, EnterococciGlycopeptide resistance screening
Liofilchem® Linezolid 30 µgLinezolidGram-positive cocciOxazolidinone class AST
Liofilchem® Cefepime 30 µgCefepimeGram-negative bacilliBroad-spectrum cephalosporin susceptibility

Unique Advantages of Liofilchem® Ceftaroline Discs

  • Precision Formulation: Delivers consistent diffusion and accurate zone measurements.
  • Regulatory Compliance: Meets international AST standards for clinical use.
  • Extended Shelf Life: Stable for 24 months when stored correctly.
  • Broad Application: Effective for routine diagnostics, surveillance, and academic research.
  • Trusted Manufacturer: Produced by Liofilchem®, a globally recognized provider of IVD microbiology products.

For In Vitro Diagnostic Use Only. Not for therapeutic use.

Application: Antimicrobial Susceptibility and Resistance Testing (AST)
Storage Temperature: 2-8°C
Product Type: Antibiotic Disc
Product Brand: Liofilchem
Product Grade: Microbiology grade

The Liofilchem® Ceftaroline (CPT) Antimicrobial Susceptibility Discs, 30 µg are designed for in vitro disc diffusion testing to determine the susceptibility of bacteria to ceftaroline, a fifth-generation cephalosporin. Ceftaroline is active against a range of Gram-positive and some Gram-negative organisms and is notable for its effectiveness against methicillin-resistant Staphylococcus aureus (MRSA).

Each disc contains 30 µg of ceftaroline, formulated according to CLSI and EUCAST standards, and is used in standardized antimicrobial susceptibility testing procedures using Mueller-Hinton agar.

These discs are widely used in clinical microbiology laboratories, hospital infection control, research, and antimicrobial surveillance programs, especially when testing for multidrug-resistant pathogens.

Key Features

  • High-quality 30 µg potency per disc, meeting international AST standards.
  • Reliable detection of ceftaroline susceptibility, especially for MRSA and other multidrug-resistant Gram-positive organisms.
  • Certified manufacturing under ISO 9001 and ISO 13485 quality management systems.
  • Ready-to-use discs individually sealed in aluminum blister packs with desiccant for optimal stability.
  • Compatible with manual and automated disc dispensers and standard AST workflows.

Specifications

AttributeDetails
Antibiotic AgentCeftaroline (CPT)
Potency30 µg
Disc Diameter6 mm
Test MethodKirby-Bauer disc diffusion
Compliant StandardsCLSI M100, EUCAST guidelines
Recommended MediaMueller-Hinton agar (standard or with additives)
Storage Conditions2–8 °C
Shelf Life24 months
Intended UseIn vitro diagnostic use (IVD)

Use Cases

1. Detection of MRSA Susceptibility to Ceftaroline

Ceftaroline is one of the few β-lactams effective against MRSA. These discs are routinely used to assess S. aureus, especially methicillin-resistant strains, for ceftaroline susceptibility to guide therapy in serious infections such as:

  • Bloodstream infections
  • Pneumonia
  • Complicated skin and soft tissue infections

2. Testing of Multidrug-Resistant Streptococci and Gram-negative Isolates

While ceftaroline has primary activity against Gram-positive cocci, it is also tested against select Gram-negative organisms such as Haemophilus influenzae and E. coli, especially in:

  • Respiratory samples
  • Surgical site infections
  • Nosocomial pathogen surveillance

3. Antibiogram Development and Resistance Surveillance

  • Used by microbiology labs to update local antibiograms.
  • Integrated into hospital stewardship programs to monitor resistance trends and inform empirical prescribing policies.

4. Research and Drug Development

Ideal for academic and clinical researchers investigating:

  • Resistance evolution in MRSA
  • Ceftaroline activity across diverse bacterial species
  • Synergy testing with other β-lactams or inhibitors

Testing Procedure

  1. Prepare the Inoculum
    • Prepare a 0.5 McFarland standard suspension of the test organism using sterile saline or broth.
  2. Inoculate the Mueller-Hinton Agar Plate
    • Swab the surface of the agar uniformly with the inoculum using a sterile swab.
  3. Apply the Ceftaroline Disc (30 µg)
    • Place one disc on the agar surface using sterile forceps or a disc dispenser.
    • Ensure discs are firmly in contact with the agar and evenly spaced.
  4. Incubate the Plate
    • Invert and incubate at 35 ± 2 °C for 16–20 hours in ambient air.
    • Use 5% CO₂ for Streptococcus pneumoniae or other fastidious organisms if needed.
  5. Measure and Interpret the Zone of Inhibition
    • Measure the diameter of the zone (in mm) with a ruler or caliper.
    • Compare zone size to CLSI or EUCAST breakpoint tables for interpretation:
      • Susceptible (S)
      • Intermediate (I)
      • Resistant (R)

Interpretation Standards (Reference – Always Check Latest CLSI/EUCAST)

OrganismSusceptible (S)Resistant (R)
Staphylococcus aureus≥ 24 mm (CLSI M100)≤ 21 mm
Streptococcus pneumoniaeRefer to CO₂-based method guidelines

Note: Always consult the current year CLSI or EUCAST documentation for accurate interpretive criteria.

Comparison with Related AST Discs

ProductAgentTarget OrganismsUse
Liofilchem® Ceftaroline (CPT) 30 µgCeftarolineMRSA, MSSA, StreptococciDetect β-lactam susceptibility in MRSA
Liofilchem® Vancomycin 30 µgVancomycinMRSA, EnterococciGlycopeptide resistance screening
Liofilchem® Linezolid 30 µgLinezolidGram-positive cocciOxazolidinone class AST
Liofilchem® Cefepime 30 µgCefepimeGram-negative bacilliBroad-spectrum cephalosporin susceptibility

Unique Advantages of Liofilchem® Ceftaroline Discs

  • Precision Formulation: Delivers consistent diffusion and accurate zone measurements.
  • Regulatory Compliance: Meets international AST standards for clinical use.
  • Extended Shelf Life: Stable for 24 months when stored correctly.
  • Broad Application: Effective for routine diagnostics, surveillance, and academic research.
  • Trusted Manufacturer: Produced by Liofilchem®, a globally recognized provider of IVD microbiology products.

For In Vitro Diagnostic Use Only. Not for therapeutic use.

No resources are currently available for this product.

This will display Shipping & Return.

The Liofilchem® Ceftaroline (CPT) Antimicrobial Susceptibility Discs, 30 µg are designed for in vitro disc diffusion testing to determine the susceptibility of bacteria to ceftaroline, a fifth-generation cephalosporin. Ceftaroline is active against a range of Gram-positive and some Gram-negative organisms and is notable for its effectiveness against methicillin-resistant Staphylococcus aureus (MRSA).

Each disc contains 30 µg of ceftaroline, formulated according to CLSI and EUCAST standards, and is used in standardized antimicrobial susceptibility testing procedures using Mueller-Hinton agar.

These discs are widely used in clinical microbiology laboratories, hospital infection control, research, and antimicrobial surveillance programs, especially when testing for multidrug-resistant pathogens.

Key Features

  • High-quality 30 µg potency per disc, meeting international AST standards.
  • Reliable detection of ceftaroline susceptibility, especially for MRSA and other multidrug-resistant Gram-positive organisms.
  • Certified manufacturing under ISO 9001 and ISO 13485 quality management systems.
  • Ready-to-use discs individually sealed in aluminum blister packs with desiccant for optimal stability.
  • Compatible with manual and automated disc dispensers and standard AST workflows.

Specifications

AttributeDetails
Antibiotic AgentCeftaroline (CPT)
Potency30 µg
Disc Diameter6 mm
Test MethodKirby-Bauer disc diffusion
Compliant StandardsCLSI M100, EUCAST guidelines
Recommended MediaMueller-Hinton agar (standard or with additives)
Storage Conditions2–8 °C
Shelf Life24 months
Intended UseIn vitro diagnostic use (IVD)

Use Cases

1. Detection of MRSA Susceptibility to Ceftaroline

Ceftaroline is one of the few β-lactams effective against MRSA. These discs are routinely used to assess S. aureus, especially methicillin-resistant strains, for ceftaroline susceptibility to guide therapy in serious infections such as:

  • Bloodstream infections
  • Pneumonia
  • Complicated skin and soft tissue infections

2. Testing of Multidrug-Resistant Streptococci and Gram-negative Isolates

While ceftaroline has primary activity against Gram-positive cocci, it is also tested against select Gram-negative organisms such as Haemophilus influenzae and E. coli, especially in:

  • Respiratory samples
  • Surgical site infections
  • Nosocomial pathogen surveillance

3. Antibiogram Development and Resistance Surveillance

  • Used by microbiology labs to update local antibiograms.
  • Integrated into hospital stewardship programs to monitor resistance trends and inform empirical prescribing policies.

4. Research and Drug Development

Ideal for academic and clinical researchers investigating:

  • Resistance evolution in MRSA
  • Ceftaroline activity across diverse bacterial species
  • Synergy testing with other β-lactams or inhibitors

Testing Procedure

  1. Prepare the Inoculum
    • Prepare a 0.5 McFarland standard suspension of the test organism using sterile saline or broth.
  2. Inoculate the Mueller-Hinton Agar Plate
    • Swab the surface of the agar uniformly with the inoculum using a sterile swab.
  3. Apply the Ceftaroline Disc (30 µg)
    • Place one disc on the agar surface using sterile forceps or a disc dispenser.
    • Ensure discs are firmly in contact with the agar and evenly spaced.
  4. Incubate the Plate
    • Invert and incubate at 35 ± 2 °C for 16–20 hours in ambient air.
    • Use 5% CO₂ for Streptococcus pneumoniae or other fastidious organisms if needed.
  5. Measure and Interpret the Zone of Inhibition
    • Measure the diameter of the zone (in mm) with a ruler or caliper.
    • Compare zone size to CLSI or EUCAST breakpoint tables for interpretation:
      • Susceptible (S)
      • Intermediate (I)
      • Resistant (R)

Interpretation Standards (Reference – Always Check Latest CLSI/EUCAST)

OrganismSusceptible (S)Resistant (R)
Staphylococcus aureus≥ 24 mm (CLSI M100)≤ 21 mm
Streptococcus pneumoniaeRefer to CO₂-based method guidelines

Note: Always consult the current year CLSI or EUCAST documentation for accurate interpretive criteria.

Comparison with Related AST Discs

ProductAgentTarget OrganismsUse
Liofilchem® Ceftaroline (CPT) 30 µgCeftarolineMRSA, MSSA, StreptococciDetect β-lactam susceptibility in MRSA
Liofilchem® Vancomycin 30 µgVancomycinMRSA, EnterococciGlycopeptide resistance screening
Liofilchem® Linezolid 30 µgLinezolidGram-positive cocciOxazolidinone class AST
Liofilchem® Cefepime 30 µgCefepimeGram-negative bacilliBroad-spectrum cephalosporin susceptibility

Unique Advantages of Liofilchem® Ceftaroline Discs

  • Precision Formulation: Delivers consistent diffusion and accurate zone measurements.
  • Regulatory Compliance: Meets international AST standards for clinical use.
  • Extended Shelf Life: Stable for 24 months when stored correctly.
  • Broad Application: Effective for routine diagnostics, surveillance, and academic research.
  • Trusted Manufacturer: Produced by Liofilchem®, a globally recognized provider of IVD microbiology products.

For In Vitro Diagnostic Use Only. Not for therapeutic use.

No resources are currently available for this product.

This will display Shipping & Return.