Liofilchem® Tigecycline TGC Antimicrobial Susceptibility Discs, 15 µg

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application Microbiology
    Storage Temperature 2-8°C
    Product Type Antibiotic Disc
    Product Brand Liofilchem
    Product Grade Microbiology grade

    Standardized Discs for In Vitro Susceptibility Testing of Tigecycline-Responsive Pathogens

    Liofilchem® Tigecycline (TGC) 15 µg Discs are designed for the qualitative in vitro determination of bacterial susceptibility to tigecycline, a broad-spectrum glycylcycline antibiotic. These paper discs, impregnated with 15 micrograms of tigecycline, are used in Kirby-Bauer disc diffusion assays on Mueller-Hinton agar, enabling clinicians and microbiologists to predict clinical efficacy of tigecycline against a range of Gram-positive and Gram-negative bacteria.

    Tigecycline is particularly effective against multi-drug resistant organisms, including methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), and extended-spectrum β-lactamase (ESBL)-producing Enterobacterales. These discs are manufactured according to EUCAST and CLSI guidelines, ensuring consistent and reliable zone diameter readings for susceptibility classification.

    Key Features & Benefits

    • 15 µg of Tigecycline per Disc – Standardized for zone interpretation per CLSI/EUCAST breakpoints
    • Ready-to-Use Format – Convenient, pre-dosed filter paper discs for easy application on agar plates
    • High-Quality Cellulose Discs – Ensure even diffusion and uniform antimicrobial activity
    • Reliable Detection of Resistance – Particularly suited for MDR pathogens including CRE, MRSA, and VRE
    • Traceable Lot & Expiration Info – Ensures regulatory compliance and batch consistency
    • Compliant with International Standards – Conforms to CLSI M100 and EUCAST performance criteria

    Technical Specifications

    ParameterDetails
    Product NameTigecycline (TGC) Antimicrobial Discs
    Active AgentTigecycline
    Concentration15 µg per disc
    FormatPaper discs, ready to use
    Disc Diameter6 mm
    Color CodeAs per Liofilchem coding (refer to label)
    PackagingTypically 50 or 100 discs per cartridge (check variant)
    Storage Conditions2–8 °C, in original packaging, away from light and moisture
    Shelf LifeIndicated on product label (usually 24 months from manufacture)
    ComplianceCLSI / EUCAST / ISO 20776-1 compliant

    🧫 Applications

    • Antibiotic Susceptibility Testing (AST) via disc diffusion (Kirby-Bauer method)
    • Routine testing in clinical microbiology labs for detection of tigecycline susceptibility
    • Surveillance of MDR organisms in hospital and reference laboratories
    • Research on tigecycline activity against emerging resistant strains
    • Evaluation of empiric therapy options in nosocomial infections

    🦠 Target Pathogens

    • Staphylococcus aureus (including MRSA)
    • Enterococcus faecalis / Enterococcus faecium (including VRE)
    • Escherichia coli, Klebsiella pneumoniae, Enterobacter spp. (including ESBL producers)
    • Acinetobacter baumannii
    • Streptococcus agalactiae, Streptococcus pneumoniae
    • Other Enterobacterales and non-fermenters

    🧪 Usage Guidelines

    1. Prepare a bacterial lawn on Mueller-Hinton agar according to CLSI/EUCAST protocols.
    2. Place the TGC 15 µg disc on the agar surface using sterile forceps or a disc dispenser.
    3. Incubate at 35 ± 2°C for 16–20 hours (24 hours for slower-growing organisms).
    4. Measure the diameter of the inhibition zone in millimeters.
    5. Interpret results using the most recent CLSI or EUCAST breakpoints.

    ⚠ Always refer to the latest standard guidelines and antibiogram charts for interpretation.

    📦 Ordering Information

    ProductCodePackaging
    Liofilchem® Tigecycline 15 µg Discs9147250 discs per pack

    🧴 Storage and Handling

    • Store at 2–8 °C in a sealed container with desiccant
    • Do not freeze
    • Bring to room temperature before opening to avoid condensation
    • Use within stated expiry date
    • Avoid exposure to humidity and light to preserve antimicrobial potency


    The Liofilchem® Tigecycline TGC 15 µg Antimicrobial Susceptibility Discs are a vital tool for clinical and research laboratories involved in the detection of tigecycline susceptibility, especially in multidrug-resistant organisms. Manufactured to strict international standards and offering reliable, reproducible results, these discs support informed antimicrobial stewardship and effective infectious disease management.