VWR Hitachi Chromaster Complete HPLC system pre-configured for use with standard columns
Catalog No :
CAS Number :
Brand :
In Stock
Chromaster HPLC system including 5160 quaternary gradient pump max. pressure 600 bar with manual purge valve and 6 channel degasser
5260 autosampler with low carry-over loop injection and 175 µl syringe
5310 oven for max. 3 x 300 mm columns
5410 variable wavelength UV detector with 13 µl, 10 mm flow cell
Chromaster System Manager control and data acquisition software included
Specifications:
Application | HPLC | Warranty | 1 Year |
Storage Temperature | Ambient | ||
Product Type | Laboratory Equipment | ||
Product Brand | VWR | ||
Product Grade | Analytical grade | ||
The Chromaster Plus HPLC System is a high-performance liquid chromatography (HPLC) system designed for superior analytical performance, durability, and flexibility. Engineered with a 600 bar pressure rating, this system is suitable for a wide range of applications, from routine analysis to complex research in pharmaceutical, food & beverage, and environmental testing.
The latest version of the Chromaster Plus features a modern, user-friendly design and enhanced components, including the CM5310 column oven and CM5410 UV detector, providing precise temperature control and superior detection capabilities. With compatibility across multiple chromatography software platforms, the Chromaster Plus offers seamless integration into laboratory workflows.
Key Features & Benefits
1. High-Performance HPLC System for Versatile Applications
- 600 bar system pressure for high-resolution separation.
- Compatible with a wide range of mobile phases and sample types.
- Designed for pharmaceutical, food safety, environmental, and chemical analysis.
2. Enhanced Detection & Temperature Control
- CM5310 column oven ensures precise thermal stability for consistent retention times.
- CM5410 variable wavelength UV detector provides high sensitivity and selectivity.
- Additional detector options for fluorescence, refractive index, and diode array detection (PDA).
3. Intuitive User Interface & Software Compatibility
- Modern touchscreen display for easy system control and method setup.
- Compatible with Hitachi ChromAssist, Agilent OpenLab CDS, Waters Empower, and DataAppex ChromAssist.
- Network installation or workstation mode for flexible data management.
4. Robust, Reliable & Low Maintenance
- Over 40 years of HPLC innovation and engineering ensures long-lasting performance.
- Low operating costs with readily available spare parts.
- Extended 3-year warranty for peace of mind.
5. Multi-Detection Capabilities for Advanced Analysis
- Multiple detector options allow users to customize the system for specific applications.
- Fluorescence, UV, diode array, and refractive index detectors available.
- Optical systems designed for precision, sensitivity, and reliability.
Specifications
Component | Description |
---|---|
Pump | CM5160 manual purge quaternary gradient pump |
Autosampler | CM5260 standard loop autosampler |
Column Oven | CM5310 with improved thermal stability |
Detector | CM5410 variable wavelength UV detector |
Max Pressure | 600 bar |
Wavelength Range | UV Detector: 190–600 nm |
Software Compatibility | ChromAssist, Agilent OpenLab CDS, Waters Empower, DataAppex ChromAssist |
Light Sources | Deuterium (D₂), Tungsten (W), Xenon (Xe), Mercury (Hg) |
Refractive Index Range (RI Detector) | 1 – 1.75 RIU |
Noise Levels | ≤2.5 × 10⁻⁹ RIU |
Drift (RI Detector) | ≤0.2 × 10⁻⁶ RIU/h |
Fluorescence Detection Range | Ex: 200 – 850 nm; Em: 250 – 900 nm |
System Manager Software | Full control of Chromaster HPLC System |
Available Detector Options
Detector Model | Detection Type | Wavelength Range |
---|---|---|
CM5410 UV Detector | Variable Wavelength | 190 – 600 nm |
CM5420 UV-VIS Detector | UV-Visible Detection | 190 – 900 nm |
CM5430 PDA Detector | Diode Array Detection (PDA) | 190 – 900 nm |
CM5440 Fluorescence Detector | Fluorescence Detection | Ex: 200 – 850 nm; Em: 250 – 900 nm |
CM5450 RI Detector | Refractive Index Detection | 1 – 1.75 RIU |
Software & Connectivity
Feature | Description |
---|---|
Software Compatibility | ChromAssist, Agilent OpenLab CDS, Waters Empower, DataAppex ChromAssist |
PC Requirements | Windows 7 Professional 32-bit version |
Data Transfer | USB, Ethernet, RS232 connectivity |
Automation | Compatible with automated autosamplers and sample handling systems |
Applications
1. Pharmaceutical & Biotech Industry
- Analysis of active pharmaceutical ingredients (APIs).
- Quality control for drug formulation and stability testing.
- Impurity profiling and dissolution testing.
2. Food & Beverage Testing
- Detection of contaminants and food additives.
- Analysis of vitamins, preservatives, and sweeteners.
- Food safety and quality control applications.
3. Environmental & Chemical Analysis
- Analysis of water, soil, and air contaminants.
- Detection of pesticides, heavy metals, and pollutants.
- Forensic and toxicology screening.
4. Petrochemical & Industrial Applications
- Analysis of fuels, lubricants, and polymers.
- Characterization of complex chemical formulations.
- High-precision component analysis.
Storage & Handling
- Store in a temperature-controlled laboratory environment.
- Regularly clean and calibrate the system for optimal performance.
- Use high-quality solvents and buffers for best analytical results.
Ordering Information
Catalog Number | Description | System Components |
---|---|---|
903-0337 | Chromaster Plus HPLC 600 Bar System | CM5160 Pump, CM5260 Autosampler, CM5310 Column Oven, CM5410 UV Detector |
The Chromaster Plus HPLC System is a high-performance, 600-bar liquid chromatography system, offering enhanced flexibility, superior detection capabilities, and robust design. Its compatibility with major HPLC software platforms, multi-detector options, and high-throughput capabilities make it ideal for pharmaceutical, food, environmental, and chemical analysis laboratories.
Product Specification not found.
Add a Review
Customer Review
Richard Atule - bought VWR Hitachi Chromaster Complete HPLC system pre-configured for use with standard columns