  • Module

This combination does not exist.

Place Inquiry

This combination does not exist.

Specifications:
Application Microbiology Warranty 1 Year
Storage Temperature Room Temperature
Product Type Microbial ID System
Product Brand Gile Scientific
Product Grade Microbiology grade

 

BROTH MICRODILUTION MIC PLATE READING

BIOMIC V3 automates the reading and interpretation of broth microdilution MIC plates* for human and veterinary labs. This improves the accuracy, speed and standardization of reading.  AI algorithms generate test results and assist user decision making and reporting including pattern matching, character recognition, and image analysis.

An enlarged plate image is instantly displayed on screen with well results and interpretations. BIOMIC V3 reads turbidity and color wells with brightfield and darkfield lighting. Results and images are saved automatically and can be printed or sent via LIS/LIMS.  Plate images can be captured using a top camera reader (larger unit with monitor) and bottom camera reader (smaller unit).  

BIOMIC V3 Reads:
  • Sensititre (Thermo Scientific) plates*
  • MicroScan (Beckman Coulter) plates*
  • MICRONAUT (Bruker) plates*
  • ComASP (Liofilchem) plates*
  • Custom Broth Microdilution plates​​​

Quality Control & Inventory Management software is included with this module. 

Broth Microdilution MIC Plate* Examples

Sensititre GNX3F* - Darkfield Lighting

Sensititre COMPGN1F* (Veterinary) - Darkfield Lighting

Custom Broth Microdilution Plate*

MicroScan Combo AST-ID Plate* - Darkfield Lighting

MICRONAUT Gram Positive Plate* - Darkfield Lighting

ComASP* Cefiderocol - Sample A

Sensititre GNX3F* - Brightfield Lighting

Sensititre COMPGN1F* (Veterinary) - Brightfield Lighting

Sensititre YeastOne YO-9 Plate*

MicroScan Combo AST-ID Plate* -Brighfield Lighting

MICRONAUT Gram Positive Plate* Brightfield Lighting

ComASP* Cefiderocol - Sample B

 

DISK DIFFUSION 

The BIOMIC V3 Microbiology System provides automated reading, interpreting, and expert review of CLSI or EUCAST antibiotic disk diffusion (Kirby-Bauer) tests on 90-150mm plates. This greatly improves accuracy, speed, and standardization of testing.  AI algorithms generate test results and assist user decision making and reporting including pattern matching, character recognition, and image analysis.

An enlarged plate image with antibiotic disks and zone diameter reading is displayed with the option to adjust on-screen by the user. Test results and high resolution images are saved automatically and may be printed or sent to your lab's LIS/LIMS. 

BIOMIC V3 automates:
  • Disk position
  • Drug code recognition (for BD & Oxoid disks)
  • Zone diameter reading
  • S-I-R interpretation (based on CLSI or EUCAST guidelines)​​

Quality Control & Inventory Management software is included with this module. 

Plate Lighting  

BIOMIC V3 customers may adjust the lighting source on-screen to help read plates with poor or weak growth.   Each plate image is saved with multiple lighting options for future review.

90mm Plate with Top Lighting

90mm Plate with Bottom (Transmitted) Lighting

Plate Image Filters

BIOMIC V3 customers may select from 6 image filters to help visualize difficult-to-read zones.  

Image Filter 1 - Natural

Image Filter 3 - Enhance Blue

Image Filter 5 - Contrast

Image Filter 2 - Brighten

Image Filter 4 - Enhance White

Image Filter 6 - Multi-Channel

Resistance Monitoring & Antibiogram Reports

BIOMIC V3 provides antibiotic resistance monitoring following current CLSI or EUCAST guidelines.  This includes a variety of antibiogram reports including Cumulative Susceptibility, Trend Chart/Graph by Susceptibility Category, Trend Graph by Zone Diameter, Distribution Graph by Zone Diameter, Location Specimen & Organism Count, Single-Drug Organism Tracking, Multi-Drug Organism Tracking, and more.  Select the report below to enlarge image.

 Automated Disk Code Recognition

BIOMIC V3 automatically recognizes antibiotic disk codes for BD and Oxoid disks.  For example, BD disk code AM-10 is recognized as Ampicillin.  If a BIOMIC V3 customer uses disks from a different manufacturer (example: Liofilchem), the customer would simply assign the disk positions on the plate during a one-time setup.

BD

Oxoid

 Rapid AST Direct from Positive Blood Culture

​Rapid AST direct from positive blood culture guidelines from EUCAST (RAST) and CLSI are included with this module. 

4 hour incubation - EUCAST RAST

6 hour incubation - EUCAST RAST

8 hour incubation - EUCAST RAST


COLONY COUNT


​BIOMIC V3 automatically counts bacterial, yeast, and mould colonies and virus plaque assays on agar plates with color digital imaging technology. This saves 99% of reading time and eliminates subjective variation and transcription errors. 


Plate images are displayed in high resolution with counting tools and options available on-screen. Parameters can be defined to optimize counting performance and accuracy. Plate images and results are saved for future review.


Chromogenic agar ID is included with the Colony Count module. 

Colony Count - Plate Types

3M Petrifilm

Ames Assay

Blood Plate

Chromogenic Agar

Filter Paper

Large Colonies

Phage/Plaque Assay

Pour Plate

Spiral Plate

Water Sample

Colony Count - Reading Options

  • Read any size plate up to 150mm
  • Read entire plate, half-plate, quadrants, or custom defined areas
  • Differentiate colonies based on size 
  • Differentiate counted colonies based on color similarities
  • Adjust contrast setting for difficult to read plates
  • Adjust counted area to exclude plate rims and ridges 
  • Manually add or delete colonies (marked as a different color)
  • Separate touching colonies into multiple counts
  • Smallest detectable colony: 0.05 mm
  • Smallest size discrimination: 0.08 mm
  • Average multiple plate counts
  • Customize plate reading formats
  • Customize printout formats
  • On-screen instructions displayed 

Options: Exclude Plate Rim & Separate Touching Colonies

Options: Count Multiple Size Ranges & Colors

Options: Exclude Area & Divide Large Colonies Into Multiple Counts​

Options: Set High Count Limit. Too Numerous To Count (TNTC)​​

AGAR DILUTION* & STEERS REPLICATOR

The BIOMIC V3 Microbiology System provides automated reading, interpreting, and expert review of CLSI and EUCAST agar dilution tests. This greatly improves accuracy, speed, and standardization of testing.  BIOMIC V3 is currently the only automated agar dilution plate reader available. 

An enlarged plate image with automated growth spot reading (growth / no growth) is displayed with the option to adjust on-screen by the user. Test results and high resolution images are saved automatically and may be sent to your lab's LIS/LIMS. 

BIOMIC V3 automates:
  • Standard agar dilution 
  • Commercial agar dilution
  • ​​Custom agar dilution

​QC & Inventory Management software is included with this module. 

 Agar Dilution - Standard Plate

Agar Dilution - 90mm Plate                                                               Custom Agar Dilution - 8x8 Square Plate

URINE SCREEN

BIOMIC V3's Urine Screen module analyzes microtiter plates containing chromogenic agar to screen out negative urine samples. This BIOMIC V3 software module allows high volume microbiology labs to process thousands of urine samples per day with limited manual intervention.


​Urine Screen Overview

Microtiter plates containing chromogenic agar are inoculated with manual or automated pipettes.  After a 12 hour incubation, BIOMIC V3 instantly reads plate wells as negative, inconclusive, or positive based on color image analysis. Users review all results on-screen and can edit as needed.


Negative results are reported 'No Pathogen Isolated'. Additional comments may be added: 'Mixed Enteric Organisms Isolated', 'Mixed Growth', 'Insignificant Growth', 'No Growth'.  Positive results are reported e.g. 'Significant E. Coli Isolated' based on chromogenic agar color.


​Inconclusive wells may be changed to positive or negative on-screen. Inconclusive and positive results may be traditionally plated for count and ID.  Confirmed test results are saved and exported via text file. 

Urine Screen Advantages:

1) Rapid, cost effective elimination of negative urines

2) Highly automated workflow with instant plate reading

3) High resolution plate images saved 

Test results list on left column. Green outline of well = Negative. Yellow outline of well = Inconclusive. Red outline of well = Positive

Negative Wells

Positive Wells

Indeterminate* Wells 

*User confirms as positive or negative on-screen

  • Module:   Disk Diffusion Testing Module MIC Strip reading Module Organism ID module Colony Count module Urine Screen module 96-Well Microtiter plate reading module, Includes Bottom Camera Reader
Resources file not found.