Varioskan™ LUX multimode microplate reader (Absorbance, Fluorescence Intensity, Luminescence)

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Reading Options: Top
No. of dispensers: None

Conditions générales
Garantie satisfait ou remboursé de 30 jours
Expédition : 2-3 jours ouvrables

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application molecular biology Warranty 1 Year
    Storage Temperature Ambient
    Product Type Laboratory Equipment
    Product Brand Thermo Fisher Scientific™
    Product Grade Molecular Biology

    The Thermo Scientific™ Varioskan™ LUX Multimode Microplate Reader (VL0L00D0) offers a flexible, accurate, and efficient platform for multimode microplate-based assays.

    It integrates absorbance (UV-Vis), fluorescence intensity, and luminescence measurement technologies within a compact and modular system designed to meet the needs of modern bioscience researchers.

    Engineered for assay flexibility, performance reliability, and ease of use, this system supports a wide range of applications including cell-based assays, enzyme kinetics, DNA/RNA quantification, and luminescent reporter analysis.

    The Varioskan LUX features automatic dynamic range selection, smart safety controls, and powerful SkanIt™ Software—ensuring consistent, high-quality data with minimal setup and user intervention.

    Key Features and Benefits

    1. Multimode Detection Capabilities

    • Combines Absorbance (UV-Vis 200–1000 nm), Fluorescence Intensity, and Luminescence detection.
    • Optimized top reading optics ideal for solution-based and homogeneous assays.
    • Dual monochromator design enables flexible wavelength selection for excitation and emission.
    • Compatible with 6–1536 well plates and μDrop plates for small-volume samples.
    • Spectral scanning for assay optimization and peak wavelength identification.

    2. Enhanced Sensitivity and Dynamic Range

    • Fluorescence Sensitivity: <0.4 fmol fluorescein/well (top read).
    • Luminescence Sensitivity: <7 amol ATP/well (white 384-well plate).
    • Dynamic Range:
      • Fluorescence: >6 decades.
      • Luminescence: >7 decades.
    • Photometric Accuracy: ±2% (200–399 nm) and ±1% (400–1000 nm).
    • Precision: SD <0.001 Abs or CV <0.5% at 450 nm (0–3 Abs).
    • Linearity: ±2% (96-well: 0–4 Abs; 384-well: 0–3 Abs at 450 nm).

    3. Reliable and Automated Operation

    • Automatic dynamic range selection ensures optimal signal intensity per well.
    • Smart safety controls detect errors before they impact results.
    • Automated self-calibration and instrument diagnostics maintain precision over time.
    • Multiple measurement modes: Endpoint, kinetic, spectra, kinetic spectra, and multipoint.
    • Orbital shaking and temperature regulation (ambient +4°C to 45°C) for consistent assay conditions.

    4. SkanIt™ Software for Intuitive Data Control

    • Includes Thermo Scientific™ SkanIt™ PC Software (Research Edition).
    • License-free multi-user installation for flexible access.
    • Virtual Pipetting Tool simplifies sample layout and experimental setup.
    • Real-time spectra and kinetic curve display.
    • Automatic data saving prevents loss during power interruptions.
    • Built-in calculations: Blank subtraction, standard curve, dose-response, kinetic, spectral, and custom formula analysis.
    • Flexible export formats: *.xlsx, *.pdf, *.xml, *.txt; automated email report option.

    5. Certified and Upgradeable

    • HTRF™ certified by Cisbio Bioassays for homogenous TR-FRET applications.
    • DLReady™ validated by Promega Corporation for luminescence assays.
    • Modular design allows future upgrades to include AlphaScreen™, TR-FRET, and TRF technologies.

    Technical Specifications

    ParameterSpecification
    Measurement TechnologiesAbsorbance, Fluorescence Intensity, Luminescence
    Reading OptionsTop
    Wavelength RangeAbsorbance: 200–1000 nm; Fluorescence Excitation: 200–822 nm; Emission: 270–840 nm; Luminescence: 360–670 nm
    Measurement Speed15 s (96-well), 45 s (384-well), 135 s (1536-well)
    Dynamic RangeFluorescence: >6 decades; Luminescence: >7 decades
    Sensitivity<0.4 fmol fluorescein/well (fluorescence); <7 amol ATP/well (luminescence)
    Accuracy (Photometric)±2% (200–399 nm, 0–2 Abs); ±1% (400–1000 nm, 0–3 Abs)
    PrecisionSD <0.001 Abs or CV <0.5% at 450 nm
    Linearity±2% (96-well: 0–4 Abs; 384-well: 0–3 Abs)
    Spectral Scanning Speed<2.2 s/well (400–500 nm, 2 nm step)
    Light SourceXenon Flash Lamp
    Detector TypePhotomultiplier Tube (PMT)
    Incubation TemperatureAmbient +4°C to 45°C
    ShakingOrbital
    InterfacePC Software (SkanIt™ Software)
    Software LanguagesEnglish, French, German, Spanish, Portuguese, Italian, Japanese, Chinese
    Dimensions (W × D × H)53 × 58 × 51 cm (21 × 23 × 20 in)
    Weight56 kg (123 lb)
    Power Requirements100–240 V, 50/60 Hz
    Plate Formats6–1536 well plates (Absorbance up to 384 wells), μDrop plates
    Software EditionResearch Edition

    Applications

    • Molecular Biology: DNA, RNA, and protein quantification using absorbance and fluorescence.
    • Enzyme Kinetics: Real-time enzyme activity and inhibition monitoring.
    • Cell-Based Assays: Reporter gene, viability, and cytotoxicity studies.
    • Luminescent Assays: ATP detection, luciferase gene expression, and bioluminescence.
    • Fluorescence-Based Studies: FRET, GFP, and probe-based analysis.
    • Spectral Scanning: Excitation/emission optimization for assay development.
    • Drug Discovery: High-throughput fluorescence and luminescence screening.

    Unique Advantages

    • Integrates Absorbance, Fluorescence Intensity, and Luminescence in one platform.
    • Optimized top reading optics for microplate and solution-based assays.
    • Automatic calibration and dynamic range control enhance reproducibility.
    • HTRF™ and DLReady™ certifications ensure validated performance.
    • Modular design for future technology upgrades.
    • SkanIt™ Software provides powerful, intuitive control and comprehensive data management.

    The Thermo Scientific™ Varioskan™ LUX Multimode Microplate Reader (VL0L00D0) delivers high-performance multimode detection across absorbance, fluorescence, and luminescence technologies.

    Engineered for reliability, sensitivity, and modular flexibility, it offers automated calibration, smart error prevention, and seamless data control through SkanIt™ Software.

    Ideal for research laboratories, biotechnology centers, and pharmaceutical facilities, the Varioskan LUX simplifies multimode assay workflows while maintaining accuracy and reproducibility for every application.

    Product Specification not found.

    Accessory Products


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    28209





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review