Specifications:
Application Antimicrobial Susceptibility and Resistance Testing (AST)
Storage Temperature -20°C
Product Type MIC Strips
Product Brand Liofilchem
Product Grade Microbiology grade

The Liofilchem™ MTS™ Minocycline (MN) MIC Test Strips are a precise diagnostic tool for determining the minimum inhibitory concentration (MIC) of minocycline against bacterial pathogens. These gradient-based strips are essential in clinical microbiology, research, and pharmaceutical settings for assessing bacterial susceptibility to minocycline, a broad-spectrum tetracycline antibiotic.

Key Features:

  1. Wide MIC Range:
    • Detects MIC values from 0.016 to 256 µg/mL, accommodating a broad range of bacterial susceptibilities.
  2. Advanced Gradient Technology:
    • Creates a continuous concentration gradient of minocycline on the strip for precise MIC determination.
  3. High-Quality Manufacturing:
    • Complies with CLSI (Clinical and Laboratory Standards Institute) and EUCAST (European Committee on Antimicrobial Susceptibility Testing) guidelines for accuracy and reliability.
  4. Ready-to-Use:
    • Pre-calibrated and pre-sterilized strips simplify testing and reduce preparation time.
  5. Broad Spectrum of Activity:
    • Effective against gram-positive and gram-negative bacteria, including multidrug-resistant strains.
  6. Cost-Effective and Efficient:
    • Eliminates the need for serial dilutions, reducing labor and reagent usage.

Applications:

  1. Clinical Diagnostics:
    • Determines bacterial susceptibility to minocycline, guiding effective antimicrobial therapy.
  2. Research and Development:
    • Supports studies on resistance mechanisms, efficacy of minocycline, and new treatment strategies.
  3. Pharmaceutical Quality Control:
    • Ensures the efficacy of minocycline formulations during drug development and production.
  4. Antimicrobial Resistance Surveillance:
    • Monitors resistance trends in pathogens for public health purposes.

Use Cases:

  1. Respiratory Infections:
    • Assesses MIC for pathogens such as Haemophilus influenzae and Streptococcus pneumoniae.
  2. Skin and Soft Tissue Infections:
    • Evaluates susceptibility of Staphylococcus aureus (including MRSA) and Streptococcus pyogenes.
  3. Urinary Tract Infections (UTIs):
    • Determines minocycline MIC for Escherichia coli and Enterococcus faecalis.
  4. Multidrug-Resistant Infections:
    • Tests efficacy against resistant strains like Acinetobacter baumannii and Klebsiella pneumoniae.
  5. Bloodstream Infections:
    • Identifies MIC for pathogens causing sepsis, such as Enterobacter cloacae and Pseudomonas aeruginosa.

Specifications:

FeatureDetails
Antimicrobial AgentMinocycline (MN)
MIC Range0.016 to 256 µg/mL
FormatGradient MIC Test Strip
Strip Dimensions5 mm x 50 mm
Storage Conditions2°C to 8°C
Shelf LifeValid until the expiry date on the label

Testing Procedure:

  1. Preparation:
    • Inoculate a Mueller-Hinton agar plate with a standardized bacterial suspension (e.g., 0.5 McFarland standard).
  2. Strip Application:
    • Using sterile forceps or an applicator, place the MTS™ Minocycline strip on the agar surface.
  3. Incubation:
    • Incubate the plate at 35°C for 16–20 hours in an aerobic atmosphere.
  4. MIC Reading:
    • Observe the inhibition ellipse intersecting the strip.
    • Read the MIC value where the ellipse touches the strip scale.

Advantages:

  1. Precision and Accuracy:
    • Gradient technology enables highly accurate MIC determination, ensuring reliable results.
  2. Ease of Use:
    • Ready-to-use strips minimize preparation time and handling errors.
  3. Broad Applicability:
    • Effective against a wide spectrum of bacterial species, including multidrug-resistant strains.
  4. Validated Performance:
    • Regular quality control ensures compliance with international standards.

Pathogens Typically Tested:

  • Staphylococcus aureus (including MRSA)
  • Escherichia coli
  • Haemophilus influenzae
  • Acinetobacter baumannii
  • Klebsiella pneumoniae
  • Pseudomonas aeruginosa
  • Enterobacter cloacae
  • Streptococcus pneumoniae

Quality Control:

  • Control Strains:
    • Escherichia coli ATCC® 25922 (susceptible).
    • Staphylococcus aureus ATCC® 29213 (susceptible).
    • Pseudomonas aeruginosa ATCC® 27853 (negative control, resistant).
  • Routine quality control ensures consistent and reproducible results.

Storage and Handling:

  • Store at 2°C to 8°C in a dry, dark environment.
  • Avoid exposure to moisture or prolonged room temperature storage.
  • Use strips before the labeled expiration date.

Product Details:

Product NameDescriptionQuantity
MTS™ Minocycline StripsMIC Test Strips (0.016–256 µg/mL) for MinocyclinePack of 10, 30, or 100 strips

Use in Clinical and Research Settings:

  • Infection Management:
    • Guides antimicrobial therapy by providing precise MIC values for resistant and sensitive strains.
  • Public Health:
    • Monitors emerging resistance patterns in clinical and environmental isolates.
  • Pharmaceutical Development:
    • Supports new drug formulations by assessing minocycline activity.

The Liofilchem™ MTS™ Minocycline MIC Test Strips are a reliable and precise tool for determining bacterial susceptibility to minocycline. Their advanced gradient technology, broad-spectrum application, and ease of use make them an indispensable resource in clinical diagnostics, antimicrobial resistance surveillance, and microbiological research.

  • Pack Size:   100/pk 10/pk 30/pk
Resources file not found.

Accessory Products


Add a Review

Rate this Product  
Name *
Email *

Your Review *
29039





0

0  Reviews
(0) 
(0) 
(0) 
(0) 
(0) 

Customer Review




Showing 0 Of 0