"1000-holes" fast GC
Oven temperature range: +3 ambient to 450°C
Temperature programming: 32-ramps/33-plateaus
Maximum heating rate: 125°C/min
Cool down time: 450°C to 50°C in less than 4 minutes
Heated zones: Seven independent zones
Communication: LAN interface and USB port

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application Gas Chromatography Warranty 1 Year
    Storage Temperature Ambient
    Product Type Analytical Instrument
    Product Brand Thermo Fisher Scientific™
    Product Grade Analytical grade

    The Thermo Scientific™ TRACE™ 1600 for MS Gas Chromatography System is a high-performance, modular gas chromatograph designed specifically for integration with mass spectrometry (GC-MS) systems. Engineered to maximize laboratory efficiency, uptime, and workflow flexibility, the TRACE 1600 GC provides precise separation of volatile and semi-volatile compounds prior to mass spectrometric detection.

    With its advanced modular iConnect™ injector and detector system, integrated backflush capability, and intelligent SmartStatus™ instrument monitoring, the TRACE 1600 ensures reliable, reproducible results while minimizing downtime and operational costs. It is ideal for demanding applications in environmental testing, food safety, forensic science, pharmaceuticals, petrochemicals, and research laboratories.

    Key Features

    Modular iConnect™ Technology

    • Tool-free interchangeable injector and detector modules
    • Rapid maintenance and replacement without service intervention
    • Reduced downtime and increased instrument availability

    Optimized for GC-MS Integration

    • Designed specifically for seamless coupling with Thermo Scientific MS systems
    • Provides precise chromatographic separation prior to mass spectrometry detection
    • Enhances analytical sensitivity and compound identification

    SmartStatus™ Instrument Monitoring

    • Real-time system health tracking through Chromeleon™ CDS
    • Alerts for maintenance, consumable replacement, and readiness
    • Enables predictive maintenance and reduced downtime

    Integrated Backflush Technology

    • Removes unwanted high-boiling contaminants after analysis
    • Reduces column contamination
    • Improves system uptime and column lifetime

    Advanced Temperature Control

    • Oven temperature range: Ambient +3°C to 450°C
    • Fast heating rate up to 125°C/min
    • Rapid cool-down: 450°C to 50°C in <4 minutes

    Reduced Operating Costs

    • Lower helium consumption with optimized injector design
    • Energy-efficient operation with fast startup
    • Compatible with standard consumables

    Applications

    • Pesticide residue analysis (GC-MS)
    • Environmental testing (VOC, SVOC analysis)
    • Food safety and contamination testing
    • Pharmaceutical quality control
    • Petrochemical analysis
    • Forensic toxicology
    • Chemical research and development

    Detector and Injector Compatibility

    Supports up to two injectors and detectors, including:

    Injectors:

    • Split/Splitless (SSL)
    • Programmable Temperature Vaporizer (PTV)
    • Cold On-Column (COC)
    • Gas Sampling Valve (GSV)

    Detectors:

    • Flame Ionization Detector (FID)
    • Thermal Conductivity Detector (TCD)
    • Electron Capture Detector (ECD)
    • Nitrogen Phosphorus Detector (NPD)
    • Flame Photometric Detector (FPD)
    • Pulsed Discharge Detector (PDD)
    • Mass Spectrometer (MS)

    Technical Specifications

    ParameterSpecification
    Product NameTRACE™ 1600 for MS Gas Chromatograph
    Catalog NumberMI-148000-0005
    Voltage230 V
    Temperature RangeAmbient +3°C to 450°C
    Heating RateUp to 125°C/min
    Cool Down Time<4 minutes (450°C to 50°C)
    Dimensions (H × W × D)45 × 44 × 67 cm
    Injector CapacityUp to 2 injectors
    Detector CapacityUp to 2 detectors plus MS
    ControlChromeleon™ CDS software
    ConnectivityFull GC-MS integration capability

    Workflow Integration in GC-MS Systems

    Typical workflow:

    1. Sample injected into GC injector
    2. Compounds separated in GC column
    3. Individual compounds enter mass spectrometer
    4. MS detects and quantifies compounds
    5. Software processes and reports results

    Advantages for Laboratory Operations

    • Increased instrument uptime
    • Faster analysis and turnaround time
    • Reduced maintenance downtime
    • Improved analytical accuracy and reproducibility
    • Lower operational costs
    • Easy maintenance and operation

    Compliance and Certifications

    Conforms to:

    • Machinery Directive 2006/42/EC
    • Low Voltage Directive 2006/95/EC
    • Electromagnetic Compatibility Directive 2004/108/EC

    Compatibility

    Designed for integration with:

    • Thermo Scientific™ ISQ™ Series GC-MS systems
    • Thermo Scientific™ TSQ™ Series GC-MS/MS systems
    • Thermo Scientific™ Chromeleon™ Chromatography Data System

    The Thermo Scientific™ TRACE™ 1600 for MS Gas Chromatography System delivers exceptional performance, modular flexibility, and seamless GC-MS integration for advanced analytical laboratories. Its innovative iConnect technology, SmartStatus monitoring, and robust chromatographic performance make it an ideal solution for high-throughput, regulatory-compliant analysis in environmental, food safety, pharmaceutical, and forensic applications.

    Product Specification not found.

    Accessory Products


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    33598





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review