Specifications:
| Application | Trace Metal Analysis |
| Storage Temperature | Ambient |
| Product Type | Analytical Instrument |
| Product Brand | Thermo Fisher Scientific™ |
| Product Grade | Analytical grade |
The Thermo Scientific™ iCAP™ PRO XP ICP-OES is a high-performance, simultaneous ICP optical emission spectrometer engineered for the demanding analysis of high-matrix and trace elemental samples. Designed for laboratories that require ruggedness, sensitivity, and multi-element analytical capability, this compact benchtop system combines robust plasma generation, advanced optical design, and intelligent software control to deliver reliable results across a wide range of applications.
Built with a vertical torch configuration, purged echelle polychromator, and CID array detector, the iCAP PRO XP offers excellent resolution, broad wavelength coverage, and long-term analytical stability. Its duo plasma viewing capability enables both axial and radial observation, allowing users to optimize sensitivity and dynamic range depending on sample type and concentration. With support for high-salt matrices, organic samples, and routine to advanced workflows, the system is ideal for environmental, industrial, food, pharmaceutical, and research laboratories.
The instrument also supports sustainability goals through ACT label certification, helping laboratories reduce environmental impact while maintaining analytical excellence.
Key Features
- Duo plasma viewing (axial and radial) for flexible analysis of both trace and higher concentration elements
- Simultaneous echelle spectrometer for rapid multi-element detection
- CID821 detector with full wavelength coverage from 167 to 852 nm
- Enhanced UV mode for improved sensitivity and lower detection limits in the UV region
- Vertical torch design for robust plasma handling and improved tolerance to difficult matrices
- 27.12 MHz solid-state RF generator with adjustable power from 750 to 1600 W
- Three independent mass flow controllers (MFCs) for precise gas regulation and long-term stability
- Optional additional gas channel for improved handling of high-salt samples up to 30% TDS and organic matrices
- 4-channel peristaltic pump to support advanced accessories and flexible sample introduction
- Thermostatically controlled optics to reduce drift and minimize recalibration frequency
- Leak protection with interlock drain sensor to prevent sample loss and system damage
- Fast warm-up time of 5 minutes from standby for improved productivity
- Powered by Thermo Scientific™ Qtegra™ ISDS Software for method creation, acquisition, processing, and post-run review
- ACT label certified for environmentally conscious laboratory procurement
Applications
The Thermo Scientific™ iCAP™ PRO XP ICP-OES is suitable for a broad range of elemental analysis applications, including:
- Environmental water and wastewater testing
- Analysis of high-salt and high-matrix industrial samples
- Food and beverage elemental screening
- Pharmaceutical raw material and product testing
- Petrochemical and chemical analysis
- Geological and mining sample analysis
- Research and academic laboratories performing trace metal determination
- Quality control and regulatory compliance testing
Application Notes
- Application Note: Combining full spectrum read-out and innovative automation capabilities for the robust and fast analysis of major and trace elements in fertilizers using ICP-OES
- Application Note: Determination of Major and Impurity Elements in Lithium Iron Phosphate by ICP-OES [ZH]
- Application Note: Determination of Silicon in Gasoline by ICP-OES [ZH]
- Application Note: Lubricating Oil Analysis According to ASTM D5185 Using the iCAP PRO XP ICP-OES
- Application Note: Determination of Elemental Impurities in LiPF6 using ICP-OES
- Application Note: Fast, Simple Analysis of Soil and Sediment Samples According to German Soil Protection Regulations
- Application Note: Rapid, Interference-free Analysis of Water According to US EPA Method 200.7
- Application Note: Fast, Accurate, and Robust Analysis of Environmental Samples According to US EPA Method 6010D
- Application Note: Effectively Increase Sample Turnover and Boost Data Confidence using Triple Quadrupole ICP-MS
- Application Note: Rapid and Robust Determination of Silicon in Gasoline using the iCAP PRO XP ICP-OES Radial System
- Application Note: Sensitive Determination of Elements in Lithium Batteries using the iCAP PRO XP ICP-OES
- Application Note: Robust Analysis of REE in Electronic Waste
- Application Note: Analysis of Naphtha using iCAP PRO XP Radial ICP-OES
- Application Note: Determination of Major and Impurity Elements in Ternary Materials by ICP-OES [ZH]
- Application Note: Analysis of Platinum Group Elements with the iCAP PRO Series ICP-OES
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | iCAP PRO XP |
| Catalog Number | BRE731405 |
| Type | ICP-OES Duo |
| Plasma Viewing | Duo (axial and radial) |
| Spectrometer | Simultaneous echelle |
| Detector Type | CID821 |
| Wavelength Range | 167 – 852 nm |
| Spectral Bandpass | 7 pm at 200 nm |
| Torch Orientation | Vertical |
| RF Source | 27 MHz, adjustable from 750 to 1600 W |
| Plasma Gas Flow | MFC tunable, 0.0 – 20.0 L/min |
| Auxiliary Gas Flow | MFC tunable, 0.0 – 2.0 L/min |
| Nebulizer Gas Flow | MFC tunable, 0.0 – 1.5 L/min |
| Optional Additional Gas Flow | 0 – 0.25 L/min |
| Peristaltic Pump | 4-channel, 0 – 125 rpm |
| Radial Viewing Height | 6 – 18 mm |
| Standard Sampling Kit | Concentric glass nebulizer, glass cyclonic spray chamber, EMT Duo torch, 2 mm bore quartz center tube |
| Purge Gas Flow | 3.4 L/min |
| Warm-Up Time | 5 minutes from standby |
| Dimensions (D × W × H) | 690 × 615 × 933 mm |
| Software | Thermo Scientific™ Qtegra™ Intelligent Scientific Data Solution™ Software |
| Unit Size | Each |
Advantages of the iCAP™ PRO XP ICP-OES
The iCAP PRO XP is built for laboratories that need both analytical sensitivity and operational ruggedness. Its compact design reduces bench space demands, while its robust plasma system and optional gas addition make it especially effective for challenging matrices such as saline and organic samples. The combination of full-spectrum wavelength access, enhanced UV capability, and duo viewing provides a strong balance of detection performance and analytical flexibility.
In addition, the Qtegra ISDS software platform enhances workflow efficiency by enabling method setup, wavelength addition, sample analysis, and data post-processing during acquisition. This helps laboratories improve throughput while maintaining confidence in data quality.
Sustainability Benefit
The iCAP PRO Series ICP-OES has received ACT label certification from My Green Lab, reflecting verified environmental impact reporting across manufacturing, energy use, water use, packaging, and end-of-life considerations. This makes the iCAP PRO XP a strong choice for laboratories seeking to align performance with sustainability objectives.
The Thermo Scientific™ iCAP™ PRO XP ICP-OES is a rugged, compact, and highly capable elemental analysis platform designed for laboratories handling routine to demanding sample matrices. With its duo viewing system, simultaneous echelle optics, enhanced UV sensitivity, intelligent software integration, and environmentally certified design, it offers an excellent solution for laboratories seeking precise, stable, and efficient ICP-OES performance.
0