Invitrogen™ eBioscience™ CD24 Monoclonal Antibody (eBioSN3 (SN3 A5-2H10)), eFluor™ 450

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

条款和条件
30天退款保证
运输:2-3 个工作日

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application Flow Cytometry, Cell Analysis
    Storage Temperature 2-8°C
    Product Type antibody Forms Liquid
    Product Brand Thermo Fisher Scientific™
    Product Grade Molecular Biology

    The Invitrogen™ CD24 Monoclonal Antibody (eBioSN3 (SN3 A5-2H10)), conjugated to eFluor™ 450, is a high-performance antibody specifically designed for flow cytometric analysis. This antibody targets CD24, a glycosylphosphatidylinositol (GPI)-anchored glycoprotein expressed on B cells, myeloid lineage cells, and certain cancer cell types. With bright fluorescence emission and excellent specificity, this antibody is an essential tool for immunophenotyping, cancer research, and studying B-cell development and regulation.

    Key Features:

    1. Target and Specificity:
      • Recognizes CD24, also known as Heat Stable Antigen (HAS), a 35–50 kDa molecule involved in B-cell development, regulation, and cancer progression.
    2. Clone and Conjugate:
      • Clone: eBioSN3 (SN3 A5-2H10), ensuring high specificity and reproducibility.
      • Conjugate: eFluor™ 450, a bright fluorochrome with excitation at 405 nm and emission at 445 nm, offering a reliable alternative to Pacific Blue®.
    3. Applications:
      • Validated for flow cytometry and immunocytochemistry (ICC/IF).
      • Ideal for detecting CD24 expression on various cell types, including lymphocytes, erythrocytes, and cancer cells.
    4. Pre-Titrated and Ready-to-Use:
      • Each test is pre-titrated for ease of use, requiring only 5 µL (0.25 µg) per 100 µL of sample for optimal staining.
    5. High Performance:
      • Provides bright fluorescence and low background for clear and reliable flow cytometric data.

    Specifications:

    AttributeDetails
    Catalog Number48-0247-42
    TargetHuman CD24 (Heat Stable Antigen, HAS)
    CloneeBioSN3 (SN3 A5-2H10)
    Host/IsotypeMouse / IgG1, kappa
    ConjugateeFluor™ 450
    ApplicationsFlow Cytometry, Immunocytochemistry (ICC/IF)
    Species ReactivityHuman
    Concentration5 µL/Test
    FormulationLiquid, in PBS (pH 7.2) with 0.2% BSA and 0.09% sodium azide
    Excitation/Emission Max405 nm / 445 nm
    Storage Conditions4°C (protect from light, do not freeze)
    Unit Size100 Tests
    Recommended Isotype ControlMouse IgG1 kappa Isotype Control (P3.6.2.8.1), eFluor™ 450

    Applications:

    1. Flow Cytometry:
      • Detects CD24 expression on granulocytes, B cells, thymocytes, and other cell types.
      • Provides high sensitivity for identifying cell populations in human peripheral blood samples.
    2. Immunocytochemistry (ICC/IF):
      • Suitable for detecting CD24 localization in fixed cells or tissue samples.
    3. Cancer Research:
      • Investigate the role of CD24 in tumorigenesis, particularly in breast cancer, lung cancer, and other malignancies where CD24 expression is a key marker.
    4. B-Cell Research:
      • Analyze B-cell development, proliferation, and regulation of autoimmunity.

    Key Benefits:

    1. Bright Fluorescence:
      • eFluor™ 450 provides clear and stable signal detection, ideal for multicolor flow cytometry panels.
    2. High Specificity and Sensitivity:
      • The eBioSN3 clone offers reliable detection of CD24-expressing cells with minimal background noise.
    3. User-Friendly:
      • Pre-titrated and ready-to-use formulation simplifies experimental workflows.
    4. Reproducibility:
      • Validated for flow cytometry and immunocytochemistry, ensuring consistent and reproducible results.
    5. Versatile Research Tool:
      • Applicable in studies of immune regulation, cancer progression, and B-cell biology.

    Usage Recommendations:

    1. Sample Preparation:
      • Stain 10⁵–10⁸ cells per test in a final volume of 100 µL using 5 µL of antibody solution.
    2. Flow Cytometry:
      • Analyze using a flow cytometer equipped with a violet laser (405 nm).
    3. Fixation:
      • Use suitable fixation buffers to preserve fluorochrome integrity.

    Storage and Handling:

    • Store at 4°C in the dark to protect the eFluor™ 450 signal.
    • Do not freeze to prevent damage to the antibody or fluorochrome.

    Target Information:

    • CD24 (Heat Stable Antigen):
      • A GPI-anchored glycoprotein expressed during B-cell development and on various cancers.
      • Plays a role in cell adhesion, immune response regulation, and tumorigenesis.
      • Expressed in normal granulocytes, thymocytes, peripheral lymphocytes, and erythrocytes.

    For Research Use Only:

    This product is intended for research purposes only and is not for diagnostic or therapeutic applications.

    Product Specification not found.

    Accessory Products


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    29153





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review




    Showing 0 Of 0