Specifications:
Application | Filtration | Warranty | 1 Year |
Storage Temperature | Ambient | ||
Product Type | Laboratory Equipment | ||
Product Brand | VWR | ||
Product Grade | Analytical grade | ||
The VWR® E Series Water Purification System is a compact, high-performance laboratory water purification solution that utilizes advanced EDI (Electrodeionization) technology to convert tap water into Type II laboratory-grade water. Designed for reliability, compliance, and ease of use, this system meets or exceeds international standards including ASTM, CAP, CLSI, ISO 3696, BS 3997, and both European and U.S. Pharmacopoeia requirements.
The system is ideal for laboratories requiring consistent high-purity water for applications such as reagent preparation, buffer solutions, microbiology, analytical instrumentation, and clinical diagnostics. Its modern design integrates real-time monitoring, RFID tracking of consumables, and an intelligent dispensing system for both single and multiple user environments.
Key Features and Benefits
High-Purity Type II Water
The VWR® E Series delivers ultrapure Type II water directly from tap water, supporting applications in chemical, life science, and clinical laboratories. The water quality produced exceeds ASTM Type II specifications and is suitable for buffer and reagent preparation as well as use with analytical equipment.
Smart Dispensing System
The system is equipped with a central 8-inch waterproof touchscreen that serves as the main control console. Users can dispense water manually or via programmable volumetric control. Its “1 + N mode” enables multiple dispensers to be managed from a single unit, offering flexible installation across multiple workspaces. The system provides a high dispensing flow rate of up to 2 L/min, enhancing efficiency in busy labs.
RFID-Tagged Consumables
The inclusion of RFID technology in the system's consumables allows for automatic recognition and tracking of cartridges, improving inventory management and minimizing the risk of improper installations or expired components. This feature simplifies maintenance and reduces system downtime.
Real-Time Monitoring and Long-Term Data Storage
The VWR® E Series continuously monitors Total Organic Carbon (TOC), resistivity, and conductivity to ensure compliance with laboratory water quality standards. Monitoring data is stored for up to two years and can be downloaded for auditing and quality assurance purposes.
Enhanced Water Quality Stability
To maintain water quality over time, the system features a circulation mode that minimizes stagnation in the storage tank. A built-in leak protection mechanism enhances laboratory safety by preventing accidental water leakage or system overflow.
Certified Quality and Regulatory Compliance
The VWR® E Series is supplied with a Certificate of Conformity and a Certificate of Calibration (for temperature and resistivity meters). The system is manufactured in facilities certified to ISO 9001:2015 and ISO 14001 standards, ensuring product reliability and environmental responsibility.
Applications and Use Cases
-
Laboratory Reagent and Chemical Preparation
Used in the preparation of buffers, media, and chemical reagents for research and quality control laboratories requiring consistent water purity. -
Analytical Chemistry and Instrumentation
Ideal for HPLC, ICP, and mass spectrometry applications where low TOC and consistent conductivity are essential for accurate analysis. -
Clinical and Medical Applications
Supports medical laboratories by delivering purified water for diagnostic analyzers, serum fractionation, and medical device rinsing. -
Microbiology and Cell Culture
Provides water suitable for microbiological testing, culture media preparation, and pharmaceutical applications requiring sterility and low contaminant levels.
System Specifications
Parameter | E5 Model | E10 Model | E15 Model |
---|---|---|---|
Feed Water Source | Tap water | Tap water | Tap water |
Production Flow Rate | 5 L/h | 10 L/h | 15 L/h |
Dispensing Flow Rate | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min |
TOC Content | <30 ppb | <30 ppb | <30 ppb |
Resistivity at 25 °C | >5 MΩ·cm (typically 10–15 MΩ·cm) | >5 MΩ·cm (typically 10–15 MΩ·cm) | >5 MΩ·cm (typically 10–15 MΩ·cm) |
System Dimensions (W×D×H) | 320 × 440 × 540 mm | 320 × 440 × 540 mm | 320 × 440 × 540 mm |
Touchscreen Display | 8-inch waterproof touchscreen | 8-inch waterproof touchscreen | 8-inch waterproof touchscreen |
Water Quality Monitoring | TOC, resistivity, conductivity | TOC, resistivity, conductivity | TOC, resistivity, conductivity |
Dispenser Configuration | Single or multiple (1 + N mode) | Single or multiple (1 + N mode) | Single or multiple (1 + N mode) |
Data Storage | 2 years downloadable | 2 years downloadable | 2 years downloadable |
RFID Tracking | Yes | Yes | Yes |
Storage Tank | 30 L PE tank with sensors | 30 L PE tank with sensors | 30 L PE tank with sensors |
Sanitization | UV module | UV module | UV module |
Leak Protection | Included | Included | Included |
Certifications | CE, ISO 9001, ISO 14001 | CE, ISO 9001, ISO 14001 | CE, ISO 9001, ISO 14001 |
Compliance Standards | ASTM, CAP, CLSI, ISO 3696, BS 3997, EP, USP | ASTM, CAP, CLSI, ISO 3696, BS 3997, EP, USP | ASTM, CAP, CLSI, ISO 3696, BS 3997, EP, USP |
Starter Packages and Ordering Information
Description | Catalog Number | Package Contents |
---|---|---|
VWR E5 System Starter Setup | 171-1473 | 1× VWR® E5 System, 1× 0.2 µm PES Final Filter, 1× AC Pack, 1× P Pack, 1× RO Pack (12 L/h), 1× Cleaning Pack, 1× Leak Protector, 1× Dispenser Kit, 1× Tank Vent Filter, 1× UV Module, 1× 30 L PE Tank with Sensors |
VWR E10 System Starter Setup | 171-1474 | 1× VWR® E10 System, 1× 0.2 µm PES Final Filter, 1× AC Pack, 1× P Pack, 2× RO Packs (12 L/h), 1× Cleaning Pack, 1× Leak Protector, 1× Dispenser Kit, 1× Tank Vent Filter, 1× UV Module, 1× 30 L PE Tank with Sensors |
VWR E15 System Starter Setup | 171-1475 | 1× VWR® E15 System, 1× 0.2 µm PES Final Filter, 1× AC Pack, 1× P Pack, 2× RO Packs (16 L/h), 1× Cleaning Pack, 1× Leak Protector, 1× Dispenser Kit, 1× Tank Vent Filter, 1× UV Module, 1× 30 L PE Tank with Sensors |
Ordering Notes
- For the E5 system, order one RO Pack (12 L/h) using catalog number 171-1276.
- For the E10 system, order two RO Packs (12 L/h) using catalog number 171-1276.
- For the E15 system, order two RO Packs (16 L/h) using catalog number 171-1277.
- Accessories including wall mounting kits, purification cartridges, and wireless upgrade kits are available separately.
Regulatory and Compliance Information
The system is delivered with a Certificate of Conformity and a Calibration Certificate for temperature and resistivity meters. The manufacturing facility is certified to ISO 9001:2015 and ISO 14001 standards. The VWR® E Series complies with ASTM, CAP, CLSI, ISO 3696, BS 3997, and both European and United States Pharmacopoeia standards.
The VWR® E Series Water Purification System offers a powerful, scalable, and fully compliant solution for producing Type II laboratory-grade water from tap water. Its advanced monitoring features, RFID-enabled maintenance, high-flow dispensing, and smart touch interface make it suitable for high-demand research, analytical, and clinical environments requiring consistent and reliable water quality.
- Production flow rate: E5 system starter setup (5 L/Hr) E10 system starter setup (10 L/Hr) E15 system starter setup (15 L/Hr)