    Specifications:
    Application Karl Fischer Titration (Coulometric) Warranty 1 Year
    Storage Temperature Ambient
    Product Type Titrators
    Product Brand GR Scientific
    Product Grade Analytical grade

    The Aquamax® Karl Fischer Plus Titrator is a robust, high-precision instrument designed for the determination of trace water content using coulometric Karl Fischer titration. This advanced moisture analysis system is ideal for laboratories requiring accurate ppm-level moisture determination in samples such as oils, fuels, solvents, chemicals, and other liquids.

    The instrument combines coulometric titration with the Karl Fischer method, delivering extremely sensitive and reliable water content measurements ranging from 1 ppm up to 100% water. Its simple “press-go” operation, integrated printer, and programmable methods make it an extremely user-friendly instrument suitable for routine laboratory testing as well as on-site analysis.

    The compact and portable design, integrated battery, and removable data storage enable users to perform moisture analysis both inside and outside the laboratory, making the Aquamax KF Plus particularly useful for petroleum laboratories, chemical plants, food analysis labs, and research facilities.

    Key Features

    Simple and User-Friendly Operation

    • One-touch “Press Go” keypad operation
    • 10 programmable analytical methods
    • Multi-language interface and printout
    • Built-in high-speed thermal printer

    High Sensitivity Moisture Detection

    • Detection range from 1 μg to 200 mg water
    • Moisture range 1 ppm – 100%
    • Maximum sensitivity 0.1 μg

    Portable and Compact Design

    • Fully portable system with internal battery
    • Small footprint ideal for limited bench space
    • Removable USB flash drive for data storage

    Robust Measurement System

    • Low Drift Cell measuring vessel
    • Grease-free sealing system for easy assembly
    • Improved baseline stability and reduced drift

    Integrated Data Management

    • USB and RS232 connectivity
    • Removable flash drive for field testing
    • Compatible with Results Manager software
    • Stores statistics for up to 99 measurements

    Water Check Verification System

    The Aquamax KF Plus includes a μg verification function allowing quick performance verification of the instrument and reagents.

    The operator can inject a small volume of distilled water (e.g., 1 μL or 10 μL) to confirm that:

    • The instrument is functioning correctly
    • The Karl Fischer reagent is performing within specification


    After the verification check, the system automatically returns to the programmed analytical method, ensuring uninterrupted workflow.

    Tough Measuring Vessel Design

    The instrument uses a Low Drift Cell (LDC) measuring vessel, specifically engineered for:

    • Improved measurement stability
    • Reduced baseline drift
    • Easy assembly and cleaning
    • No grease or PTFE sleeves required

    The electrode locking system ensures tight sealing and reliable operation during titration.

    Results Manager Software

    The Results Manager software provides comprehensive data management:

    • Download results directly from the titrator
    • View and analyze test results
    • Print detailed analytical reports
    • Export measurement data for record keeping

    The system can also store results on a USB flash drive for later analysis on a computer.

    Measurement Principle

    The Aquamax KF Plus uses coulometric Karl Fischer titration, one of the most sensitive techniques for water determination.

    In this method:

    • Water reacts with iodine generated electrochemically in the titration cell
    • The reaction continues until all water in the sample is consumed
    • The amount of iodine generated corresponds directly to the water content

    This technique allows precise detection of trace moisture levels down to microgram quantities.

    Applications

    The Aquamax Karl Fischer Plus is widely used in:

    Petroleum and Fuel Analysis

    • Water content in fuels
    • Moisture in lubricating oils
    • Petrochemical product testing

    Chemical Industry

    • Moisture in solvents
    • Water determination in reagents
    • Raw material quality control

    Pharmaceutical Industry

    • Moisture determination in APIs
    • Quality control testing
    • Pharmaceutical formulations

    Food and Beverage Analysis

    • Moisture content in edible oils
    • Quality control of food ingredients

    Research Laboratories

    • Analytical chemistry studies
    • Environmental analysis
    • Materials science

    Technical Specifications

    ParameterSpecification
    Titration MethodCoulometric Karl Fischer
    Measuring Range1 μg – 200 mg water
    Typical Range1 μg – 10 mg
    Moisture Range1 ppm – 100%
    Maximum Sensitivity0.1 μg
    Max Titration Speed2.24 mg/min
    Max Current400 mA
    End Point DetectionAC Polarization
    Precision±3 μg (10–100 μg range)
    Precision Above 1 mg±0.3%

    Measurement Modes

    Calculation ModeDescription
    Weight/Weight (W/W)Moisture relative to sample mass
    Weight/Dilution Ratio (W/K)Diluted samples
    Volume/Density (V/SG)Liquid samples
    Volume/Volume (V/V)Liquid concentration

    Display and Data Handling

    FeatureSpecification
    Display40-character backlit LCD
    Print Outputμg, ppm, mg/kg, %
    StatisticsMin, max, mean for up to 99 runs
    Sample IDUser programmable
    PrinterHigh-speed thermal printer
    InterfacesUSB and RS232

    Instrument Specifications

    ParameterSpecification
    Power Supply90–264V AC, 47–63 Hz
    Stirrer SpeedMicroprocessor controlled
    Language OptionsMulti-language
    Calendar/ClockBuilt-in time and date
    Battery IndicatorLow battery alert

    Dimensions and Weight

    ParameterSpecification
    Width12 in
    Length10 in
    Height6 in
    Weight7 lb

    Certification

    Each Aquamax Karl Fischer titrator is supplied with a calibration certificate traceable to national standards, ensuring confidence in analytical accuracy.

    The Aquamax Karl Fischer Plus Titrator is a powerful and user-friendly solution for accurate trace moisture analysis using the coulometric Karl Fischer method. Its high sensitivity, portable design, robust measurement system, and advanced data management capabilities make it an ideal instrument for laboratories performing water content determination in petroleum products, chemicals, pharmaceuticals, and food samples. With reliable performance and easy operation, the Aquamax KF Plus provides laboratories with a dependable tool for ppm-level moisture analysis.

    Product Specification not found.

    Accessory Products


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    10398





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review