Agilent High sensitivity D1000 reagents, for 112 DNA Samples

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

For the high sensitivity analysis of DNA from 35 to 1000 bp, includes ladder and sample buffer sufficient for 112 samples

Termini e condizioni
Garanzia di rimborso di 30 giorni
Spedizione: 2-3 giorni lavorativi

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application Capillary Electrophoresis
    Storage Temperature 2-8°C
    Product Type Molecular Biology Reagent Forms Liquid
    Product Brand Agilent
    Product Grade Molecular Biology

    The Agilent High Sensitivity D1000 Reagents Kit is designed for precise and reproducible analysis of low-concentration DNA fragments ranging from 35 to 1000 base pairs (bp). These reagents are optimized for use with Agilent 4150 and 4200 TapeStation Systems, allowing automated, high-sensitivity DNA quality control (QC) for next-generation sequencing (NGS), PCR fragment analysis, and genomic integrity assessment.

    This kit includes a DNA ladder and sample buffer sufficient for processing 112 samples, ensuring accurate and reliable fragment size determination and quantification in high-throughput workflows.

    Key Features & Benefits

    1. High-Sensitivity DNA Analysis from 35 to 1000 bp
      • Detects low-concentration DNA samples with minimal input volume.
      • Provides accurate fragment size distribution for library QC and PCR products.
    2. Pre-Calibrated for Agilent TapeStation Systems
      • Ensures consistent, automated electrophoresis results.
      • Eliminates manual gel preparation and sample handling errors.
    3. Includes DNA Ladder & Sample Buffer for 112 Samples
      • Provides a complete reagent set for streamlined DNA analysis.
      • Pre-mixed reagents minimize preparation time and handling variability.
    4. Optimized for NGS, PCR QC & Low-Input DNA Samples
      • Ideal for small DNA fragment analysis in sequencing and amplification workflows.
      • Ensures reliable quality control for cell-free DNA, bisulfite sequencing, and forensic DNA applications.
    5. Standardized DNA Integrity & Fragment Analysis
      • Produces high-resolution electropherogram traces for clear fragment visualization.
      • Provides precise quantification for reproducible data interpretation.

    Product Specifications

    FeatureDetails
    Product NameAgilent High Sensitivity D1000 Reagents Kit
    Catalog NumberN/A
    DNA Size Range35 – 1000 bp
    Number of Samples112
    Reagents IncludedDNA Ladder, Sample Buffer
    SensitivityHigh Sensitivity for Low DNA Concentrations
    Sample Volume Required1–2 µL per sample
    CompatibilityAgilent 4150 TapeStation, Agilent 4200 TapeStation
    Typical Run Time1–2 minutes per sample
    For Use WithDNA Fragment Analysis, NGS Library QC, PCR QC
    Storage Conditions4–25°C, Protect from Light
    Shipping ConditionsAmbient Temperature

    Use Cases & Applications

    1. Next-Generation Sequencing (NGS) Library Quality Control

    • Ensures High-Quality DNA Input for NGS Workflows
      • Verifies library preparation efficiency by detecting adapter dimers and incomplete ligation products.
      • Confirms DNA fragmentation size distribution before sequencing.
    • Optimized for DNA Library QC & Low-Input DNA Analysis
      • Suitable for NGS libraries from bisulfite sequencing, ATAC-seq, and ChIP-seq.
      • Enables precise DNA integrity assessment for sensitive sequencing applications.

    2. PCR Product Validation & Amplicon Size Determination

    • Confirms PCR Fragment Sizes for Cloning & qPCR Analysis
      • Differentiates specific amplicons from non-specific bands.
      • Ensures accurate product verification in multiplex PCR.
    • High-Sensitivity Detection of DNA Amplification Products
      • Detects low-abundance DNA fragments in qPCR and endpoint PCR.
      • Ideal for forensic DNA applications and microbial DNA analysis.

    3. Genomic DNA & Cell-Free DNA (cfDNA) Analysis

    • Assess cfDNA Fragmentation for Liquid Biopsy Studies
      • Identifies nucleosomal cfDNA patterns in cancer diagnostics.
      • Detects low-concentration circulating DNA for disease biomarker research.
    • DNA Integrity Assessment for Genomic Studies
      • Measures fragmentation levels in genomic DNA for sequencing applications.
      • Supports DNA QC for long-read sequencing and structural variant analysis.

    4. Epigenetics & Low-Input DNA Research

    • Ideal for Bisulfite Sequencing & Methylation Studies
      • Provides accurate DNA integrity analysis for epigenetic profiling.
      • Detects DNA degradation caused by bisulfite treatment.
    • Facilitates Cancer Genomics & Tumor DNA Analysis
      • Ensures DNA quality control for detecting tumor-derived DNA fragments.
      • Used in high-sensitivity assays for rare variant detection.

    Instructions for Use

    Step-by-Step Protocol for TapeStation Analysis

    1. Prepare Samples & Reagents:
      • Ensure reagents (DNA ladder and sample buffer) are at room temperature before use.
      • Load 1–2 µL of sample into the TapeStation tray.
    2. Load the TapeStation System:
      • Insert the appropriate D1000 High Sensitivity DNA ScreenTape device.
      • Add prepared DNA samples to the designated wells.
    3. Run the TapeStation Analysis:
      • Start the automated electrophoresis process via TapeStation software.
      • Each sample is analyzed in 1–2 minutes.
    4. Interpret & Export Data:
      • Review electropherogram traces and gel-like images for DNA fragment analysis.
      • Export data as PDF, CSV, or LIMS-compatible formats.

    Storage & Handling Instructions

    • Storage Conditions:
      • Store at 4–25°C, protected from light.
      • Do not freeze, as it may affect reagent performance.
    • Handling Precautions:
      • Use aseptic techniques when handling DNA samples.
      • Ensure reagents remain sealed until use to prevent contamination.
    • Disposal Guidelines:
      • Dispose of used reagents as per laboratory biosafety regulations.
      • Follow institutional waste management protocols for electrophoresis consumables.

    Why Choose Agilent High Sensitivity D1000 Reagents?

    Rapid, high-sensitivity DNA quality assessment for NGS & PCR workflows

    Preloaded reagents ensure consistency & minimize sample preparation time

    Compatible with Agilent 4150 & 4200 TapeStation Systems

    Accurate fragment size analysis from 35 to 1000 bp

    Reproducible, automated DNA QC with minimal hands-on time

    The Agilent High Sensitivity D1000 Reagents Kit is a critical tool for DNA quality control in genomics, sequencing, and molecular biology applications, ensuring high-precision DNA fragment analysis with minimal sample handling.

    Product Specification not found.
    Resources file not found.

    Accessory Products


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    29378





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review




    Showing 0 Of 0