Liofilchem™ MTS™ Penicillin G P 0.002-32, MIC Test strips

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Conditions générales
Garantie satisfait ou remboursé de 30 jours
Expédition : 2-3 jours ouvrables

  • Pack Size

This combination does not exist.

Place Inquiry

This combination does not exist.

Specifications:
Application Clinical microbiology
Storage Temperature -20°C
Product Type MIC Strips
Product Brand Liofilchem
Product Grade Microbiology grade

Liofilchem™ MTS™ Penicillin G P 0.002-32 is a quantitative tool for determining the Minimum Inhibitory Concentration (MIC) of Penicillin G for bacterial isolates. These MIC test strips are primarily used for antimicrobial susceptibility testing (AST) in clinical microbiology laboratories to assess the effectiveness of Penicillin G against Gram-positive bacteria, including Streptococcus pneumoniae, Staphylococcus spp., and Enterococcus spp.

Key Features:

  • MIC Range: 0.002–32 µg/mL, allowing precise determination of Penicillin G susceptibility.
  • Target Organisms: Gram-positive bacteria, including Streptococcus pneumoniae, Streptococcus pyogenes, and Staphylococcus aureus.
  • Ease of Use: Direct application on Mueller-Hinton Agar.
  • Quantitative Results: Provides an exact MIC value for guiding therapeutic decisions.
  • Cost-Effective: Simple design eliminates the need for complex dilution setups.
  • Reference Standards: Compatible with EUCAST and CLSI guidelines for breakpoint interpretation.

Test Procedure:

  1. Preparation of Bacterial Inoculum:
    • Adjust a bacterial suspension to match the 0.5 McFarland standard.
    • Use freshly grown cultures to ensure accuracy.
  2. Agar Plate Preparation:
    • Use Mueller-Hinton Agar for non-fastidious organisms or Mueller-Hinton Agar with 5% defibrinated sheep blood for Streptococcus pneumoniae.
    • Inoculate the agar plate with the standardized bacterial suspension using a sterile swab.
  3. Application of MTS™ Penicillin G Strips:
    • Place the MTS™ Penicillin G strip on the inoculated agar surface with sterile forceps.
    • Ensure the strip adheres firmly to the agar and forms a tight seal.
  4. Incubation:
    • Incubate plates at 35 ± 2°C for 16–20 hours (aerobic atmosphere).
    • For fastidious organisms like S. pneumoniae, incubate in a 5% CO₂ atmosphere.
  5. Result Interpretation:
    • After incubation, observe the ellipse of inhibition that intersects the strip.
    • Read the MIC value at the point where the bacterial growth inhibition zone meets the strip.

Quality Control Data:

Quality control strains should be tested regularly to ensure accuracy:

OrganismExpected MIC Range (µg/mL)Interpretation
Staphylococcus aureus ATCC® 292130.25–1.0Susceptible
Streptococcus pneumoniae ATCC® 496190.01–0.06Susceptible
Escherichia coli ATCC® 25922Resistant (≥ 4.0)Reference Only

Interpretation of Results:

MIC values should be interpreted using clinical breakpoints provided by EUCAST or CLSI guidelines.

MIC (µg/mL)Interpretation
≤ 0.12Susceptible
0.25–2.0Intermediate
≥ 4.0Resistant

Comparison with Other Brands:

  1. Oxoid™ Penicillin MIC Strips:
    • Offers similar MIC determination but with a narrower range for certain pathogens.
    • Liofilchem strips provide better ease of application and a more comprehensive MIC range.
  2. Etest® Penicillin Strips:
    • Etest strips are well-established but costlier than Liofilchem™ strips.
    • Liofilchem strips are equally reliable for laboratories aiming for cost-effectiveness without compromising accuracy.
  3. Broth Microdilution:
    • Gold standard for MIC determination but requires specialized equipment and time.
    • Liofilchem strips offer an alternative that is simpler and faster, with comparable accuracy for routine clinical use.

Storage Conditions:

  • Short-term storage: Store at 2–8°C.
  • Long-term storage: Store at -20°C.
  • Avoid repeated freeze-thaw cycles to maintain strip integrity.

Conclusion:

The Liofilchem™ MTS™ Penicillin G P 0.002-32, MIC Test Strips provide a reliable, cost-effective, and efficient means to determine the susceptibility of Gram-positive organisms to Penicillin G. The strips align with international standards (EUCAST and CLSI) and are a valuable tool for guiding antimicrobial therapy decisions in clinical microbiology laboratories. Compared to other products, Liofilchem's strips offer competitive accuracy and broader availability at a lower cost, making them an ideal choice for routine testing.

  • Pack Size:   100/pk 10/pk 30/pk
Resources file not found.


Add a Review

Rate this Product  
Name *
Email *

Your Review *
28440





0

0  Reviews
(0) 
(0) 
(0) 
(0) 
(0) 

Customer Review




Showing 0 Of 0