Liofilchem™ MTS™ Azithromycin AZM 0.016-256, MIC Test strips

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Conditions générales
Garantie satisfait ou remboursé de 30 jours
Expédition : 2-3 jours ouvrables

  • Pack Size

This combination does not exist.

Place Inquiry

This combination does not exist.

Specifications:
Application Antimicrobial Susceptibility and Resistance Testing (AST)
Storage Temperature -20°C
Product Type MIC Strips
Product Brand Liofilchem
Product Grade Microbiology grade

The Liofilchem™ MTS™ Azithromycin MIC Test Strips are an advanced diagnostic tool designed to determine the minimum inhibitory concentration (MIC) of azithromycin against bacterial pathogens. These gradient-based test strips provide precise MIC values, helping clinicians and microbiologists evaluate the susceptibility of microorganisms to azithromycin for effective antimicrobial therapy.

Key Features:

  1. Wide MIC Range:
    • Detects azithromycin MIC values from 0.016 to 256 µg/mL, covering a broad range of bacterial susceptibility.
  2. Gradient Technology:
    • Creates a continuous azithromycin concentration gradient along the strip, enabling precise MIC determination.
  3. Ease of Use:
    • Pre-calibrated and ready-to-use strips eliminate preparation time, ensuring accurate and reproducible results.
  4. High Quality:
    • Manufactured under strict quality control standards, ensuring compliance with CLSI and EUCAST guidelines for susceptibility testing.
  5. Versatile Application:
    • Suitable for gram-positive and gram-negative bacterial pathogens, including those causing respiratory, skin, and sexually transmitted infections.

Applications:

  1. Clinical Diagnostics:
    • Determines the MIC of azithromycin for guiding appropriate antibiotic therapy.
  2. Antimicrobial Resistance Surveillance:
    • Monitors resistance patterns in pathogens to support public health efforts.
  3. Pharmaceutical Testing:
    • Evaluates the efficacy of azithromycin formulations during drug development and quality control.
  4. Research Microbiology:
    • Studies resistance mechanisms and evaluates azithromycin efficacy in experimental models.

Use Cases:

  1. Respiratory Infections:
    • Tests MIC for pathogens like Streptococcus pneumoniae and Haemophilus influenzae.
  2. Skin and Soft Tissue Infections:
    • Evaluates susceptibility of Staphylococcus aureus (including MRSA) to azithromycin.
  3. Sexually Transmitted Infections (STIs):
    • Determines MIC for Neisseria gonorrhoeae and Chlamydia trachomatis.
  4. Enteric Pathogens:
    • Assesses azithromycin activity against Salmonella spp. and Shigella spp..

Specifications:

FeatureDetails
Antimicrobial AgentAzithromycin (AZM)
MIC Range0.016 to 256 µg/mL
FormatGradient MIC Test Strip
Strip Dimensions5 mm x 50 mm
Storage Conditions2°C to 8°C
Shelf LifeValid until the expiry date on the label

Testing Procedure:

  1. Preparation:
    • Prepare a Mueller-Hinton agar plate and inoculate with a standardized bacterial suspension (e.g., 0.5 McFarland standard).
  2. Strip Application:
    • Place the MTS™ Azithromycin strip onto the agar surface using sterile forceps or an applicator.
  3. Incubation:
    • Incubate the plate at 35°C for 16–20 hours in an aerobic atmosphere.
  4. MIC Reading:
    • Observe the ellipse of growth inhibition intersecting the strip.
    • Read the MIC value at the point where the inhibition ellipse touches the strip.

Advantages:

  1. Precise MIC Values:
    • Gradient technology ensures accurate determination of azithromycin susceptibility.
  2. User-Friendly:
    • Easy to apply and interpret with minimal training.
  3. Broad Applicability:
    • Suitable for a wide range of bacterial species and clinical scenarios.
  4. Reproducible Results:
    • High-quality manufacturing ensures consistent and reliable results across batches.

Storage and Handling:

  • Store at 2°C to 8°C in a dry environment, away from light and moisture.
  • Avoid prolonged exposure to room temperature to maintain strip potency.
  • Use strips before the labeled expiration date.

Product Details:

Product NameDescriptionQuantity
MTS™ Azithromycin StripsMIC Test Strips (0.016–256 µg/mL) for AzithromycinPack of 10, 30, or 100 strips

Pathogens Typically Tested:

  • Streptococcus pneumoniae
  • Haemophilus influenzae
  • Staphylococcus aureus (including MRSA)
  • Neisseria gonorrhoeae
  • Salmonella spp.
  • Shigella spp.

Quality Control:

  • Control Strains:
    • Escherichia coli ATCC® 25922 (susceptible).
    • Staphylococcus aureus ATCC® 29213 (susceptible).
    • Haemophilus influenzae ATCC® 49247 (susceptible).
  • Routine quality control ensures compliance with CLSI and EUCAST standards.

The Liofilchem™ MTS™ Azithromycin (AZM) MIC Test Strips, 0.016–256 µg/mL offer a precise and reliable method for determining azithromycin susceptibility in clinical, research, and industrial microbiology applications. Their gradient technology and broad-spectrum utility make them indispensable for guiding antimicrobial therapy and monitoring resistance trends.

  • Pack Size:   100/pk 10/pk 30/pk
Resources file not found.

Accessory Products


Add a Review

Rate this Product  
Name *
Email *

Your Review *
29038





0

0  Reviews
(0) 
(0) 
(0) 
(0) 
(0) 

Customer Review




Showing 0 Of 0