VWR® Autoclavable bags, PP, 40 µm thick, clear without Biohazard Print
Catalog No :
CAS Number :
Brand :
In Stock
Specifications:
Application | sterilization |
Storage Temperature | Ambient |
Product Type | Laboratory Waste Management |
Product Brand | VWR |
Product Grade | Laboratory grade |
The VWR® Autoclavable Bags are high-temperature-resistant, clear polypropylene (PP) waste disposal bags, specifically designed for safe and efficient disposal of laboratory waste, including pipette tips, disposable Petri dishes, and sample tubes. These 40 µm thick, clear bags offer leak-proof, puncture-resistant containment and are suitable for autoclaving at up to 145°C.
✔ Heat resistant up to 145°C – Autoclavable for safe decontamination
✔ Made from durable, 40 µm thick polypropylene (PP) – Tear-resistant and leak-proof
✔ Clear, without 'Biohazard' printing – Ideal for general lab waste disposal
✔ Available in multiple sizes – Suitable for different laboratory waste volumes
✔ Eco-friendly and compliant with laboratory waste management standards
✔ For laboratory and research use.
Key Features & Benefits
✔ High-Temperature Resistance & Autoclavable
- Withstands temperatures up to 145°C, ensuring safe decontamination before disposal.
- Prevents leaks, breakages, and contamination during sterilization.
✔ Strong & Durable Material
- Made from 40 µm thick polypropylene (PP) to provide high tear resistance.
- Reliable containment of lab waste without risk of puncture or spills.
✔ Clear & Unlabeled for Versatile Use
- Transparent for easy waste identification, reducing mislabeling risks.
- Suitable for both general and non-hazardous lab waste disposal.
✔ Multiple Size Options for Different Lab Needs
- Available in 2L to 60L capacities, accommodating small to large waste volumes.
- Can be used in benchtop setups, biohazard waste bins, or large disposal units.
✔ Environmentally Preferable & Laboratory Safe
- Meets laboratory safety and disposal regulations.
- Can be used for autoclaving solid lab waste before final disposal.
Applications & Use Cases
1. Safe Disposal of General Laboratory Waste
- Purpose: Containment of non-biohazardous waste such as gloves, pipette tips, sample tubes, and disposable plastics.
- Use Case: Used in chemistry, biology, and analytical laboratories for routine waste management.
2. Autoclaving & Sterilization Before Disposal
- Purpose: Ensures safe decontamination of non-hazardous waste before disposal.
- Use Case: Used in research labs, hospitals, and pharmaceutical industries for sterilizing lab consumables before final disposal.
3. General Laboratory Waste Containment
- Purpose: Provides clean and organized disposal of used lab materials.
- Use Case: Ideal for academic research facilities, medical labs, and cleanroom environments.
4. Chemical & Analytical Lab Waste Management
- Purpose: Stores and secures chemical-related waste during laboratory experiments.
- Use Case: Used in analytical labs, forensic labs, and industrial R&D facilities to manage waste without cross-contamination.
Available Sizes & Ordering Information
Description | Capacity | Dimensions (L × W) | Pack Size | Catalog Number |
---|---|---|---|---|
Autoclavable bags, clear | 2 L | 300 × 200 mm | 500 | 129-0578 |
Autoclavable bags, clear | 3 L | 400 × 250 mm | 500 | 129-0579 |
Autoclavable bags, clear | 12 L | 660 × 305 mm | 500 | 129-0580 |
Autoclavable bags, clear | 14 L | 610 × 420 mm | 500 | 129-0582 |
Autoclavable bags, clear | 16 L | 780 × 400 mm | 500 | 129-0581 |
Autoclavable bags, clear | 25 L | 770 × 550 mm | 500 | 129-0583 |
Autoclavable bags, clear | 32 L | 780 × 600 mm | 500 | 129-0584 |
Autoclavable bags, clear | 40 L | 1100 × 700 mm | 350 | 129-0585 |
Autoclavable bags, clear | 60 L | 1100 × 900 mm | 100 | 129-0586 |
Product Specifications
Attribute | Details |
---|---|
Material | Polypropylene (PP) |
Thickness | 40 µm |
Heat Resistance | Up to 145°C |
Autoclavable | Yes |
Color | Clear |
Biohazard Printing | No |
Packaging Type | Bulk Pack (100-500 Bags) |
Disposal | Laboratory Waste Management Protocols |
Sterilization Method | Autoclave |
Storage & Handling
✔ Store in a clean, dry place to maintain integrity.
✔ Ensure bags are sealed properly before autoclaving.
✔ Dispose of in accordance with laboratory waste management regulations.
Regulatory & Compliance Information
- Compliant with laboratory waste disposal standards.
- Meets sterilization and decontamination safety protocols.
- Recommended for use in research, medical, and industrial laboratories.
The VWR® Autoclavable Bags (Clear, Without Biohazard Print) offer a reliable, high-quality solution for general lab waste disposal. These polypropylene bags are heat-resistant up to 145°C, autoclavable, and puncture-resistant, making them ideal for research labs, medical facilities, and industrial applications.
With multiple sizes (2L to 60L) available, these clear, unmarked waste bags provide safe, compliant, and efficient laboratory waste management.
- Size: 2 L, 300×200 mm, 500/Case 3 L, 400×250 mm, 500/case 12 L, 660×305 mm, 500/case 14 L, 610×420 mm, 500/case 16 L, 780×400 mm, 500/case 25 L, 770×550 mm, 500/case 32 L, 780×600 mm, 500/case 40 l, 1100×700 mm, 350/case 60 L, 1100×900 mm, 100/case