NANOPORE Technologies Rapid Barcoding Kit, 3 x 96 reactions

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Simple and rapid library preparation, with barcoding for up to 96 gDNA samples.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application Next Generation Sequencing
    Storage Temperature -20°C
    Product Type Sequencing Reagents
    Product Brand Oxford Nanopore Technology
    Product Grade Molecular Biology

    The Rapid Sequencing Kits and Rapid Barcoding Kits V14 from Oxford Nanopore Technologies provide a quick and efficient method to prepare sequencing libraries from genomic DNA (gDNA). These kits are specifically designed for use on ONT devices such as MinION™, and they streamline workflows for sequencing native DNA while preserving base modifications.

    Key Features

    1. Rapid Sequencing of Native DNA

    • Preserves Native Characteristics:
      • No PCR amplification required, eliminating PCR-induced bias.
      • Enables detection of base modifications (e.g., methylation) alongside the nucleotide sequence.
    • Speed and Simplicity:
      • Library preparation in as little as 10 minutes for singleplex Rapid Sequencing Kits.
      • ~60 minutes for multiplex workflows using Rapid Barcoding Kits.
    • Minimal Equipment:
      • Simplified process requiring basic laboratory equipment.

    2. Multiplexing with Rapid Barcoding Kits

    • Multiplex Up to 96 Samples:
      • Attach barcoded tags to template DNA to pool samples in a single sequencing run.
      • Useful for cases where individual sample data requirements are lower than the capacity of a flow cell.
    • Efficient Use of Resources:
      • Reduces cost per sample and maximizes sequencing throughput by pooling multiple samples.
    • Compatible Kits:
      • Rapid Barcoding Kit 24: For multiplexing up to 12 samples.
      • Rapid Barcoding Kit 96: For multiplexing up to 96 samples.

    3. Workflow

    1. Fragmentation and Tagging:
      • A transposase cleaves the DNA and simultaneously attaches tags to the cleaved ends.
    2. Adapter Ligation:
      • Rapid Sequencing Adapters are ligated to the tagged DNA ends.
    3. Barcoding (for Rapid Barcoding Kits):
      • Unique barcodes are attached to the DNA ends, allowing multiple samples to be pooled.
    4. Pooling and Sequencing:
      • Pooled samples are loaded onto ONT flow cells for sequencing.
      • Barcoded reads are classified and sorted using MinKNOW software.

    4. High Accuracy and Performance

    • Chemistry Upgrade:
      • V14 chemistry is optimized for speed and simplicity, delivering improved accuracy and higher output with R10.4.1 Flow Cells.
    • Q20+ Accuracy:
      • Capable of generating modal raw read accuracies of Q20+ (≥99%).
    • Long Reads:
      • Long DNA fragments in the sample allow the generation of very long reads, despite transposase-induced fragmentation.

    Kit Specifications

    FeatureRapid Sequencing KitRapid Barcoding Kits V14
    Preparation Time10 minutes~60 minutes
    MultiplexingSingle sampleUp to 96 samples
    Input Requirement100 ng gDNA per sample50 ng gDNA per sample
    PCR RequirementNoneNone
    WorkflowFragmentation, tagging, adapter ligationSame, with barcoding step
    Sequencing AccuracyQ20+ (≥99%)Q20+ (≥99%)
    ApplicationsSingle sample sequencingMultiplex sequencing

    Compatibility

    • Devices: MinION™, GridION™, and PromethION™.
    • Flow Cells: R10.4.1 flow cells.

    Applications

    • Whole-genome sequencing.
    • Epigenetic studies (e.g., methylation detection).
    • Pathogen surveillance.
    • Large-scale genomic studies with multiplexed samples.

    Advantages

    1. Time-Efficient:
      • Drastically reduces library preparation time compared to traditional methods.
    2. Cost-Effective:
      • Multiplexing reduces cost per sample.
    3. PCR-Free:
      • Retains DNA base modifications and eliminates amplification biases.
    4. High Throughput:
      • Compatible with ONT devices for large-scale sequencing.

    Shipping and Storage

    • Shipped at 2–8°C.
    • Store at -20°C upon receipt.
    • Shelf life: 3 months from delivery.

    Safety and Legal Note

    • Not intended for health assessment, disease diagnosis, or treatment purposes.

    The ONT Rapid Sequencing and Rapid Barcoding Kits V14 provide a user-friendly, efficient, and accurate approach to sequencing, catering to both small-scale and large-scale genomic studies. Their fast preparation time, multiplexing capabilities, and PCR-free workflows make them invaluable for modern sequencing applications.

    Product Specification not found.
    Resources file not found.


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    19668





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review




    Showing 0 Of 0