The Eppendorf Centrifuge 5804/5804 R is a high-performance benchtop centrifuge designed for medium-throughput applications requiring speeds of up to 20,913 × g (14,000 rpm). Available in both refrigerated (5804 R) and non-refrigerated (5804) models, this centrifuge offers exceptional versatility, reliability, and cost-effectiveness for laboratories handling molecular biology, clinical, pharmaceutical, and cell culture workflows.
With a broad selection of rotors and adapters, the 5804 series accommodates tubes, bottles (0.2 mL to 250 mL), and multiwell plates (MTP, PCR, deep-well plates), making it a versatile and scalable centrifugation solution.
Key Features & Benefits
1. High-Speed, Medium-Throughput Centrifugation
- Maximum Speed: 14,000 rpm (20,913 × g) for high-performance applications.
- Supports various rotors and adapters, accommodating tubes, bottles, and plates.
- Cost-effective centrifuge for labs requiring versatility and reliability.
2. Versatile Rotor & Adapter Compatibility
- Swing-bucket rotors support tubes and bottles from 0.2 mL to 250 mL.
- Fixed-angle rotors accommodate tubes from 0.2 mL to 85 mL.
- Plate rotor for multiwell plate centrifugation, including PCR, cell culture, and deep-well plates.
3. Energy-Efficient Operation
- Rotor S-4-72 offers aerodynamic design, reducing energy consumption by up to 48%.
- Eco-friendly cooling system in refrigerated models (5804 R) optimizes temperature control.
- Aerosol-tight rotor options available for safe handling of hazardous samples.
4. Enhanced Safety & Ergonomic Handling
- Eppendorf QuickLock® lid ensures fast and secure rotor locking.
- Lightweight rotors (FA-45-6-30: 3.2 kg) improve ease of handling.
- 45° borehole angle minimizes pellet smearing, ensuring high-quality sample processing.
5. Advanced Performance & Control
- Intuitive control panel with digital display for speed and time settings.
- Pre-programmable runs and acceleration/deceleration profiles.
- Quiet operation and low vibrations for a comfortable lab environment.
Rotor Options
1. Rotor S–4–72 (Swing-Bucket Rotor for Medium-Throughput Applications)
- Maximum Speed: 4,200 rpm (3,234 × g).
- Accommodates tubes from 0.2 mL to 250 mL with a broad range of adapters.
- Energy-saving aerodynamic bucket design, reducing power consumption by up to 48%.
- Autoclavable buckets and adapters for enhanced sterility.
2. Rotor FA–45–6–30 (Fixed-Angle Rotor for High-Speed Applications)
- Capacity: 6 × 50 mL tubes.
- Maximum Speed:
- 20,130 × g (12,100 rpm) in Centrifuge 5810 R.
- 16,639 × g (11,000 rpm) in Centrifuge 5804/5804 R.
- Aerosol-tight for safe centrifugation of hazardous samples.
- Eppendorf QuickLock® lid for easy locking and unlocking.
Specifications
| Property | Eppendorf Centrifuge 5804 | Eppendorf Centrifuge 5804 R |
|---|---|---|
| Model Type | Non-Refrigerated | Refrigerated |
| Max Speed | 14,000 rpm | 14,000 rpm |
| Max RCF | 20,913 × g | 20,913 × g |
| Capacity | Tubes: 0.2–250 mL, Plates: MTP, PCR, Deep-Well | Tubes: 0.2–250 mL, Plates: MTP, PCR, Deep-Well |
| Temperature Range | Ambient | –9°C to 40°C |
| Rotor Options | Swing-bucket, Fixed-angle, Plate Rotors | Swing-bucket, Fixed-angle, Plate Rotors |
| Lid Locking | Eppendorf QuickLock® | Eppendorf QuickLock® |
| Noise Level | Low Noise | Low Noise |
| Safety Features | Imbalance detection, Lid Interlock | Imbalance detection, Lid Interlock |
| Weight | 60 kg | 70 kg |
Applications
1. Molecular Biology & Clinical Applications
- Pelleting of nucleic acids, proteins, and cellular components.
- DNA/RNA extraction and purification workflows.
- Centrifugation of PCR tubes and microplates for assay preparation.
2. Cell Culture & Bioprocessing
- Separation of cell suspensions, bacterial cultures, and yeast samples.
- Pelleting of eukaryotic cells for downstream applications.
- Processing deep-well plates for high-throughput experiments.
3. Pharmaceutical & Biotechnology Laboratories
- High-speed centrifugation for sample concentration.
- Protein precipitation and purification procedures.
- Preparation of virus stocks and exosome isolation.
Storage & Handling
- Store in a dry, ventilated space with access to power supply.
- Regular maintenance ensures rotor longevity and instrument performance.
- Ensure proper balance of samples before centrifugation to prevent imbalance errors.
Ordering Information
| Catalog Number | Description | |
|---|---|---|
| 5804 | Eppendorf Centrifuge 5804 (Non-Refrigerated, Without Rotor) | |
| 5804 R | Eppendorf Centrifuge 5804 R (Refrigerated, Without Rotor) |
The Eppendorf Centrifuge 5804/5804 R is a versatile, medium-throughput benchtop centrifuge that delivers exceptional performance, flexibility, and cost-effectiveness. With a broad rotor and adapter selection, it supports various applications in molecular biology, cell culture, and pharmaceutical research.
Centrifugation Certificate Compliance Centrifuge 58XX family
Centrifugation Certificate Containment Testing Centrifuge 58XX
Centrifugation Certificate EC Conformity Declaration Centrifugen 5804-R
Centrifugation Certificate Quality Conformity Eppendorf Centrifuges
Centrifugation Operating manual Centrifuge 5804/5804-R Centrifuge
Centrifugation Selection Guide
Eppendorf Centrifugation Installation guide Centrifuges
Eppendorf Centrifugation Instructions for use
Eppendorf Centrifugation Instructions for Loading buckets
The Eppendorf Centrifuge 5804/5804 R is a high-performance benchtop centrifuge designed for medium-throughput applications requiring speeds of up to 20,913 × g (14,000 rpm). Available in both refrigerated (5804 R) and non-refrigerated (5804) models, this centrifuge offers exceptional versatility, reliability, and cost-effectiveness for laboratories handling molecular biology, clinical, pharmaceutical, and cell culture workflows.
With a broad selection of rotors and adapters, the 5804 series accommodates tubes, bottles (0.2 mL to 250 mL), and multiwell plates (MTP, PCR, deep-well plates), making it a versatile and scalable centrifugation solution.
Key Features & Benefits
1. High-Speed, Medium-Throughput Centrifugation
- Maximum Speed: 14,000 rpm (20,913 × g) for high-performance applications.
- Supports various rotors and adapters, accommodating tubes, bottles, and plates.
- Cost-effective centrifuge for labs requiring versatility and reliability.
2. Versatile Rotor & Adapter Compatibility
- Swing-bucket rotors support tubes and bottles from 0.2 mL to 250 mL.
- Fixed-angle rotors accommodate tubes from 0.2 mL to 85 mL.
- Plate rotor for multiwell plate centrifugation, including PCR, cell culture, and deep-well plates.
3. Energy-Efficient Operation
- Rotor S-4-72 offers aerodynamic design, reducing energy consumption by up to 48%.
- Eco-friendly cooling system in refrigerated models (5804 R) optimizes temperature control.
- Aerosol-tight rotor options available for safe handling of hazardous samples.
4. Enhanced Safety & Ergonomic Handling
- Eppendorf QuickLock® lid ensures fast and secure rotor locking.
- Lightweight rotors (FA-45-6-30: 3.2 kg) improve ease of handling.
- 45° borehole angle minimizes pellet smearing, ensuring high-quality sample processing.
5. Advanced Performance & Control
- Intuitive control panel with digital display for speed and time settings.
- Pre-programmable runs and acceleration/deceleration profiles.
- Quiet operation and low vibrations for a comfortable lab environment.
Rotor Options
1. Rotor S–4–72 (Swing-Bucket Rotor for Medium-Throughput Applications)
- Maximum Speed: 4,200 rpm (3,234 × g).
- Accommodates tubes from 0.2 mL to 250 mL with a broad range of adapters.
- Energy-saving aerodynamic bucket design, reducing power consumption by up to 48%.
- Autoclavable buckets and adapters for enhanced sterility.
2. Rotor FA–45–6–30 (Fixed-Angle Rotor for High-Speed Applications)
- Capacity: 6 × 50 mL tubes.
- Maximum Speed:
- 20,130 × g (12,100 rpm) in Centrifuge 5810 R.
- 16,639 × g (11,000 rpm) in Centrifuge 5804/5804 R.
- Aerosol-tight for safe centrifugation of hazardous samples.
- Eppendorf QuickLock® lid for easy locking and unlocking.
Specifications
| Property | Eppendorf Centrifuge 5804 | Eppendorf Centrifuge 5804 R |
|---|---|---|
| Model Type | Non-Refrigerated | Refrigerated |
| Max Speed | 14,000 rpm | 14,000 rpm |
| Max RCF | 20,913 × g | 20,913 × g |
| Capacity | Tubes: 0.2–250 mL, Plates: MTP, PCR, Deep-Well | Tubes: 0.2–250 mL, Plates: MTP, PCR, Deep-Well |
| Temperature Range | Ambient | –9°C to 40°C |
| Rotor Options | Swing-bucket, Fixed-angle, Plate Rotors | Swing-bucket, Fixed-angle, Plate Rotors |
| Lid Locking | Eppendorf QuickLock® | Eppendorf QuickLock® |
| Noise Level | Low Noise | Low Noise |
| Safety Features | Imbalance detection, Lid Interlock | Imbalance detection, Lid Interlock |
| Weight | 60 kg | 70 kg |
Applications
1. Molecular Biology & Clinical Applications
- Pelleting of nucleic acids, proteins, and cellular components.
- DNA/RNA extraction and purification workflows.
- Centrifugation of PCR tubes and microplates for assay preparation.
2. Cell Culture & Bioprocessing
- Separation of cell suspensions, bacterial cultures, and yeast samples.
- Pelleting of eukaryotic cells for downstream applications.
- Processing deep-well plates for high-throughput experiments.
3. Pharmaceutical & Biotechnology Laboratories
- High-speed centrifugation for sample concentration.
- Protein precipitation and purification procedures.
- Preparation of virus stocks and exosome isolation.
Storage & Handling
- Store in a dry, ventilated space with access to power supply.
- Regular maintenance ensures rotor longevity and instrument performance.
- Ensure proper balance of samples before centrifugation to prevent imbalance errors.
Ordering Information
| Catalog Number | Description | |
|---|---|---|
| 5804 | Eppendorf Centrifuge 5804 (Non-Refrigerated, Without Rotor) | |
| 5804 R | Eppendorf Centrifuge 5804 R (Refrigerated, Without Rotor) |
The Eppendorf Centrifuge 5804/5804 R is a versatile, medium-throughput benchtop centrifuge that delivers exceptional performance, flexibility, and cost-effectiveness. With a broad rotor and adapter selection, it supports various applications in molecular biology, cell culture, and pharmaceutical research.
Centrifugation Certificate Compliance Centrifuge 58XX family
Centrifugation Certificate Containment Testing Centrifuge 58XX
Centrifugation Certificate EC Conformity Declaration Centrifugen 5804-R
Centrifugation Certificate Quality Conformity Eppendorf Centrifuges
Centrifugation Operating manual Centrifuge 5804/5804-R Centrifuge
Centrifugation Selection Guide
Eppendorf Centrifugation Installation guide Centrifuges
Eppendorf Centrifugation Instructions for use
Eppendorf Centrifugation Instructions for Loading buckets
Spezifikationen
| Model | keypad, non-refrigerated - 5804, keypad, refrigerated - 5804 R |