Invitrogen™ Human Hepatitis B Virus Surface Antigen ELISA Kit, 96 Tests
Catalog No :
CAS Number :
Brand :
In Stock
Specifications:
Application | ELISA-Based Assays | ||
Storage Temperature | 2-8°C | ||
Product Type | Elisa Kit | Forms | Kit with Various components |
Product Brand | Thermo Fisher Scientific™ | ||
Product Grade | Molecular Biology | ||
High-Sensitivity ELISA Kit for Quantitative Detection of HBsAg in Human Samples
The Invitrogen™ Human Hepatitis B Virus Surface Antigen (HBsAg) ELISA Kit is a highly specific and sensitive sandwich ELISA assay designed for the quantitative measurement of HBsAg in human serum, plasma, cell lysates, and tissue homogenates.
This 96-well microplate-based immunoassay is ideal for virology research, vaccine development, and hepatitis B studies. With an analytical sensitivity of 0.19 ng/mL, this kit enables accurate and reproducible detection of HBsAg levels in various biological fluids.
Key Features & Benefits
✅ Quantitative Detection of HBsAg – Measures Hepatitis B Virus Surface Antigen in human samples
✅ High Sensitivity (0.19 ng/mL) – Detects low levels of HBsAg with high accuracy
✅ Broad Assay Range (0.31 – 20 ng/mL) – Suitable for various experimental applications
✅ Validated for Multiple Sample Types – Compatible with serum, plasma, cell lysates, and tissue homogenates
✅ 96-Well Pre-Coated Microplate Format – Allows high-throughput screening
✅ Biotin-Streptavidin HRP System – Provides high specificity & signal amplification
✅ Fast & Easy Protocol (2 hr 30 min Total Time) – Reduces hands-on time for efficient research workflows
✅ Validated for Sensitivity, Specificity & Reproducibility – Ensures high precision and low inter-assay variability (<10%)
✅ For Research Use Only (RUO) – Designed for scientific and laboratory research purposes
Technical Specifications
Attribute | Details |
---|---|
Product Name | Human Hepatitis B Virus Surface Antigen (HBsAg) ELISA Kit |
Catalog Number | EEL140 |
Assay Format | Sandwich ELISA |
Detection Method | Colorimetric (HRP-TMB) |
Sensitivity | 0.19 ng/mL |
Assay Range | 0.31 – 20 ng/mL |
Inter-Assay CV | <10% |
Intra-Assay CV | <10% |
Total Assay Time | 2 hr 30 min |
Hands-On Time | 1 hr 20 min |
Number of Reactions | 96 Tests |
Sample Volume Required | 100 µL |
Sample Types | Serum, Plasma, Cell Lysates, Tissue Homogenates |
Storage Conditions | Refer to product documentation |
Shipping Conditions | Wet Ice |
Kit Components
✔ Pre-Coated 96-Well Plate (HBsAg-Specific Capture Antibody)
✔ Standard (Recombinant HBsAg Antigen, Lyophilized)
✔ Biotinylated Detection Antibody
✔ HRP Conjugate
✔ Standard & Sample Diluent
✔ Biotinylated Detection Antibody Diluent
✔ HRP Conjugate Diluent
✔ Wash Buffer
✔ TMB Substrate
✔ Stop Solution
✔ Plate Sealer
Principle of the Assay
The Human Hepatitis B Virus Surface Antigen (HBsAg) ELISA Kit is based on a solid-phase sandwich enzyme-linked immunosorbent assay (ELISA).
1️⃣ Capture Antibody Coating – The microplate wells are pre-coated with a target-specific antibody that binds to HBsAg in the sample.
2️⃣ Sample Addition & Incubation – The test sample is added to the wells, and HBsAg binds to the immobilized antibody.
3️⃣ Detection Antibody Binding – A biotinylated secondary antibody binds to a different epitope of HBsAg, forming a sandwich complex.
4️⃣ HRP Conjugate & Signal Generation – HRP-conjugated streptavidin is added, followed by TMB substrate, producing a colorimetric signal.
5️⃣ Stop Reaction & Read Absorbance – The reaction is stopped using Stop Solution, and absorbance is measured at 450 nm using a microplate reader.
The intensity of the color is proportional to the concentration of HBsAg in the sample.
Compatible Instruments
✔ Colorimetric Microplate Readers
✔ Automated ELISA Workstations
✔ Plate Readers with 450 nm Detection
Applications
🔬 Virology Research & Hepatitis B Studies – Detects HBsAg levels in clinical and research samples
🦠 Vaccine Development & Immunogenicity Testing – Evaluates immune responses in vaccine trials
🧪 Infectious Disease Research – Used in HBV pathogenesis & antiviral drug studies
⚕ Public Health & Epidemiological Surveillance – Assesses HBV prevalence in high-risk populations
🛠 Pharmaceutical & Drug Discovery – Supports HBV-targeted therapeutic development
Usage Guidelines
1️⃣ Prepare Reagents & Samples – Bring all components to room temperature before use.
2️⃣ Load Samples & Standards – Add 100 µL of sample or standard into each well.
3️⃣ Incubate & Wash – Allow binding and perform multiple wash steps to remove unbound material.
4️⃣ Add Biotinylated Detection Antibody & HRP Conjugate – Incubate and wash again.
5️⃣ Develop Color Reaction – Add TMB substrate and allow color to develop.
6️⃣ Stop & Read Absorbance – Stop reaction and measure optical density at 450 nm.
Regulatory & Safety Information
⚠️ For Research Use Only (RUO). Not intended for diagnostic or clinical applications.
⚠️ Handle Biological Samples with Caution. Follow biosafety guidelines (BSL-2 or higher) for infectious agents.
⚠️ Dispose of Used Materials Safely. Follow laboratory waste disposal regulations for hazardous substances.
Why Choose the Invitrogen™ HBsAg ELISA Kit?
🔹 Highly Sensitive & Specific Detection (0.19 ng/mL) – Ensures accurate & reproducible results
🔹 Validated for Serum, Plasma & Cell Lysates – Offers broad sample compatibility
🔹 Rapid & Efficient Workflow (2 hr 30 min Total Time) – Reduces laboratory turnaround time
🔹 Robust Assay Performance (Inter-Assay CV <10%) – Delivers consistent & high-quality data
🔹 Ideal for HBV Research, Epidemiology & Vaccine Development – Supports critical virology studies