Thermo Scientific™ Point of Use Filter Inserts
Catalog No :
CAS Number :
Brand :
In Stock
Specifications:
| Application | Water Purification |
| Storage Temperature | Ambient |
| Product Type | Filters |
| Product Brand | Thermo Fisher Scientific™ |
| Product Grade | Analytical grade |
The Thermo Scientific™ Point of Use Filter Inserts are high-performance filtration solutions designed to provide final-stage protection and water quality assurance in laboratory water purification systems. Installed directly at the point of use, these filters ensure that purified water remains free from particulates, microorganisms, and contaminants immediately before dispensing.
Available in a range of pre-filters, final filters, and sterile filters, these inserts are engineered to protect laboratory equipment, enhance water purity, and support critical applications requiring consistent, high-quality water output.
Key Features
Comprehensive Filtration Options
- Prefilters (1 µm, 3 µm, 5 µm) for removal of suspended particles and debris
- Final filters (0.45 µm) for enhanced particulate control
- Sterile filters (0.2 µm) for removal of bacteria and delivery of high-purity, biologically safe water
High Flow Rate Performance
- Supports flow rates from 500 L/hr to 3200 L/hr
- Maintains efficient filtration with minimal pressure drop (Δp = 0.2 bar)
Point-of-Use Protection
- Installed directly at the dispensing point to prevent downstream contamination
- Ensures final water quality is maintained after purification
System Protection and Longevity
- Prevents entry of undissolved substances into sensitive equipment
- Reduces risk of clogging, fouling, and contamination
- Enhances reliability of laboratory workflows
Flexible Configuration
- Available in 10-inch and 20-inch formats
- Wide range of pore sizes for tailored filtration based on application needs
- Suitable for integration into various Thermo Scientific™ Barnstead™ systems
Applications
- Final-stage filtration in laboratory water purification systems
- Protection of analytical instruments and sensitive equipment
- Microbiology and molecular biology applications requiring sterile water
- Preparation of reagents and buffers
- Pharmaceutical and clinical laboratory processes
- Academic and research laboratory workflows
Available Models and Ordering Information
| Catalog Number | Type | Flow Rate | Pore Size |
|---|---|---|---|
| 06.5101 | Prefilter Insert | 1000 L/hr | 1 µm |
| 50155506 | Prefilter Insert | 1550 L/hr | 5 µm |
| 06.5106 | Prefilter Insert | 1700 L/hr | 1 µm |
| 50155507 | Prefilter Insert | 1300 L/hr | 3 µm |
| 50155508 | Prefilter Insert | 2400 L/hr | 3 µm |
| 50155509 | Prefilter Insert | 3200 L/hr | 5 µm |
| 06.5201 | Prefilter Insert | 750 L/hr | 5 µm |
| 50155514 | Prefilter Insert | 1200 L/hr | 5 µm |
| 06.5111 | Final Filter | 1400 L/hr | 0.45 µm |
| 06.5112 | Final Filter | 2800 L/hr | 0.45 µm |
| 06.5555 | Sterile Filter Insert | 500 L/hr | 0.2 µm |
| 50155523 | Sterile Filter Insert | 1000 L/hr | 0.2 µm |
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type | Prefilter / Final Filter / Sterile Filter |
| Pore Sizes | 5 µm, 3 µm, 1 µm, 0.45 µm, 0.2 µm |
| Flow Rate Range | 500 – 3200 L/hr |
| Pressure Drop | Δp = 0.2 bar |
| Formats | 10-inch and 20-inch |
| Installation | Point-of-use |
| Unit Size | Each |
Filtration Workflow
Tap Water → Pretreatment → RO / Purification System → Storage → Point-of-Use Filter → Final Application
This ensures:
- Removal of large particulates (pretreatment)
- Removal of dissolved contaminants (RO/purification)
- Final polishing and sterility assurance (point-of-use filters)
Unique Advantages
- Ensures final water quality at the dispensing point
- Prevents recontamination after purification
- Wide selection of pore sizes for different laboratory needs
- High flow rates suitable for demanding applications
- Supports sterile and particle-free water delivery
- Enhances protection of sensitive analytical instruments
The Thermo Scientific™ Point of Use Filter Inserts are a critical component in maintaining the highest level of water purity at the final stage of laboratory workflows. By combining high-efficiency filtration with flexible configurations, these inserts ensure that purified water remains free from contaminants right up to the point of application—making them indispensable for laboratories requiring precision, reliability, and sterility.
- Flow Rate & Pore Size: Flow Rate: 1000 L/hr; Pore Size: 1 µm (Prefilter Insert) Flow Rate: 1550 L/hr; Pore Size: 5 µm (Prefilter Insert) Flow Rate: 1700 L/hr; Pore Size: 1 µm (Prefilter Insert) Flow Rate: 1300 L/hr; Pore Size: 3 µm (Prefilter Insert) Flow Rate: 2400 L/hr; Pore Size: 3 µm (Prefilter Insert) Flow Rate: 3200 L/hr; Pore Size: 5 µm (Prefilter Insert) Flow Rate: 750 L/hr; Pore Size: 5 µm (Prefilter Insert) Flow Rate: 1200 L/hr; Pore Size: 5 µm (Prefilter Insert) Flow Rate: 1400 L/hr; Pore Size: 0.45 µm (Final Filter) Flow Rate: 2800 L/hr; Pore Size: 0.45 µm (Final Filter) Flow Rate: 500 L/hr; Pore Size: 0.2 µm (Sterile Filter Insert) Flow Rate: 1000 L/hr; Pore Size: 0.2 µm (Sterile Filter Insert)