Thermo Scientific™ Point of Use Filter Inserts

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

条款和条件
30天退款保证
运输:2-3 个工作日

  • Flow Rate & Pore Size

This combination does not exist.

Place Inquiry

This combination does not exist.

Specifications:
Application Water Purification
Storage Temperature Ambient
Product Type Filters
Product Brand Thermo Fisher Scientific™
Product Grade Analytical grade

The Thermo Scientific™ Point of Use Filter Inserts are high-performance filtration solutions designed to provide final-stage protection and water quality assurance in laboratory water purification systems. Installed directly at the point of use, these filters ensure that purified water remains free from particulates, microorganisms, and contaminants immediately before dispensing.

Available in a range of pre-filters, final filters, and sterile filters, these inserts are engineered to protect laboratory equipment, enhance water purity, and support critical applications requiring consistent, high-quality water output.

Key Features

Comprehensive Filtration Options

  • Prefilters (1 µm, 3 µm, 5 µm) for removal of suspended particles and debris
  • Final filters (0.45 µm) for enhanced particulate control
  • Sterile filters (0.2 µm) for removal of bacteria and delivery of high-purity, biologically safe water

High Flow Rate Performance

  • Supports flow rates from 500 L/hr to 3200 L/hr
  • Maintains efficient filtration with minimal pressure drop (Δp = 0.2 bar)

Point-of-Use Protection

  • Installed directly at the dispensing point to prevent downstream contamination
  • Ensures final water quality is maintained after purification

System Protection and Longevity

  • Prevents entry of undissolved substances into sensitive equipment
  • Reduces risk of clogging, fouling, and contamination
  • Enhances reliability of laboratory workflows

Flexible Configuration

  • Available in 10-inch and 20-inch formats
  • Wide range of pore sizes for tailored filtration based on application needs
  • Suitable for integration into various Thermo Scientific™ Barnstead™ systems

Applications

  • Final-stage filtration in laboratory water purification systems
  • Protection of analytical instruments and sensitive equipment
  • Microbiology and molecular biology applications requiring sterile water
  • Preparation of reagents and buffers
  • Pharmaceutical and clinical laboratory processes
  • Academic and research laboratory workflows

Available Models and Ordering Information

Catalog NumberTypeFlow RatePore Size
06.5101Prefilter Insert1000 L/hr1 µm
50155506Prefilter Insert1550 L/hr5 µm
06.5106Prefilter Insert1700 L/hr1 µm
50155507Prefilter Insert1300 L/hr3 µm
50155508Prefilter Insert2400 L/hr3 µm
50155509Prefilter Insert3200 L/hr5 µm
06.5201Prefilter Insert750 L/hr5 µm
50155514Prefilter Insert1200 L/hr5 µm
06.5111Final Filter1400 L/hr0.45 µm
06.5112Final Filter2800 L/hr0.45 µm
06.5555Sterile Filter Insert500 L/hr0.2 µm
50155523Sterile Filter Insert1000 L/hr0.2 µm

Technical Specifications

ParameterSpecification
Product TypePrefilter / Final Filter / Sterile Filter
Pore Sizes5 µm, 3 µm, 1 µm, 0.45 µm, 0.2 µm
Flow Rate Range500 – 3200 L/hr
Pressure DropΔp = 0.2 bar
Formats10-inch and 20-inch
InstallationPoint-of-use
Unit SizeEach

Filtration Workflow

Tap Water → Pretreatment → RO / Purification System → Storage → Point-of-Use Filter → Final Application

This ensures:

  • Removal of large particulates (pretreatment)
  • Removal of dissolved contaminants (RO/purification)
  • Final polishing and sterility assurance (point-of-use filters)

Unique Advantages

  • Ensures final water quality at the dispensing point
  • Prevents recontamination after purification
  • Wide selection of pore sizes for different laboratory needs
  • High flow rates suitable for demanding applications
  • Supports sterile and particle-free water delivery
  • Enhances protection of sensitive analytical instruments

The Thermo Scientific™ Point of Use Filter Inserts are a critical component in maintaining the highest level of water purity at the final stage of laboratory workflows. By combining high-efficiency filtration with flexible configurations, these inserts ensure that purified water remains free from contaminants right up to the point of application—making them indispensable for laboratories requiring precision, reliability, and sterility.

  • Flow Rate & Pore Size:   Flow Rate: 1000 L/hr; Pore Size: 1 µm (Prefilter Insert) Flow Rate: 1550 L/hr; Pore Size: 5 µm (Prefilter Insert) Flow Rate: 1700 L/hr; Pore Size: 1 µm (Prefilter Insert) Flow Rate: 1300 L/hr; Pore Size: 3 µm (Prefilter Insert) Flow Rate: 2400 L/hr; Pore Size: 3 µm (Prefilter Insert) Flow Rate: 3200 L/hr; Pore Size: 5 µm (Prefilter Insert) Flow Rate: 750 L/hr; Pore Size: 5 µm (Prefilter Insert) Flow Rate: 1200 L/hr; Pore Size: 5 µm (Prefilter Insert) Flow Rate: 1400 L/hr; Pore Size: 0.45 µm (Final Filter) Flow Rate: 2800 L/hr; Pore Size: 0.45 µm (Final Filter) Flow Rate: 500 L/hr; Pore Size: 0.2 µm (Sterile Filter Insert) Flow Rate: 1000 L/hr; Pore Size: 0.2 µm (Sterile Filter Insert)

Accessory Products


Add a Review

Rate this Product  
Name *
Email *

Your Review *
34109





0

0  Reviews
(0) 
(0) 
(0) 
(0) 
(0) 

Customer Review