VWR® Qualitative Filter Papers

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

  • Grade
  • Size

This combination does not exist.

Place Inquiry

This combination does not exist.

Specifications:
Application Filtration
Storage Temperature Room Temperature
Product Type Filter Papers
Product Brand VWR
Product Grade Analytical grade

VWR® Qualitative Filter Papers are high-purity, cellulose-based filtration media designed for routine laboratory applications requiring reliable and reproducible qualitative analysis. Manufactured from nearly 100% alpha-cellulose fibers and produced under strict quality control standards, these filter papers deliver consistent filtration performance across a wide range of analytical workflows.

With a low ash content of approximately 0.06%, VWR qualitative filter papers are ideal for general laboratory filtration tasks where minimal residue is required but ashless-grade precision is not critical. Their optimized pore structures and mechanical strength ensure efficient separation of precipitates, particulates, and suspensions in chemistry, pharmaceutical, clinical, food, and environmental laboratories.

Available in multiple grades with varying retention rates and flow speeds, VWR qualitative filter papers provide tailored solutions for coarse, medium, and fine filtration applications.

Key Features

  • High Purity Cellulose Composition
    Manufactured from nearly 100% alpha-cellulose, ensuring consistent filtration quality and chemical compatibility.
  • Low Ash Content (~0.06%)
    Minimizes residue after filtration, making them suitable for most qualitative analytical procedures.
  • Wide Range of Filtration Grades
    Multiple grades available to support coarse, medium, and fine particle retention requirements.
  • Optimized Flow Rates
    Designed to balance filtration speed and retention efficiency for different laboratory workflows.
  • Mechanical Strength & Wet Stability
    Maintains integrity during filtration, even when handling gelatinous or heavy precipitates.
  • Binder-Free Construction (Selected Grades)
    Ensures minimal interference with sensitive analytical procedures.
  • Versatile Formats and Sizes
    Available in circular sheets and rolls, compatible with standard laboratory filtration setups.

Grade Selection Guide

GradeFiltration SpeedRetention LevelTypical Applications
401FastCoarseLarge precipitates (iron, aluminium hydroxides), metallurgical analysis
402 / 302MediumMediumGeneral qualitative analysis, sulphides, dairy fat determination
403 / 313Medium-FineFinePharmaceuticals, clinical labs, chromatography, protein-free filtrations
410 / 305SlowFineDifficult precipitates, analytical chemistry, wine clarification
413 / 303MediumMediumRoutine lab work, student laboratories, general chemistry
415 / 301FastCoarseGelatinous and bulky precipitates (e.g., metal hydroxides)
417Very FastLow retentionRapid filtration where fine retention is not critical
315MediumGelatinous precipitatesSpecialized filtration of viscous or gelatinous materials
307MediumSpecialtyBrewing applications, malt analysis (EBC standard)
600 / 310MediumGeneralRoutine laboratory use, universities, hospitals

Applications

Analytical Chemistry

  • Qualitative analysis of inorganic compounds
  • Filtration of metal hydroxides, sulphates, and carbonates
  • Gravimetric sample preparation

Pharmaceutical & Clinical Laboratories

  • Drug and compound analysis
  • Protein-free filtrations
  • Preparation of clear solutions for diagnostic testing

Food & Beverage Industry

  • Determination of fat content in dairy products
  • Brewing analysis (malt filtration per EBC standards)
  • Clarification of beverages such as wine

Academic & Research Laboratories

  • General chemistry experiments
  • Student laboratory filtration tasks
  • Routine sample preparation

Industrial & Environmental Testing

  • Filtration of suspended solids
  • Sample clarification for analytical workflows
  • Metallurgical and materials testing

Technical Specifications

ParameterSpecification
MaterialAlpha-cellulose (≈100%)
Ash Content~0.06%
FormatCircular sheets and rolls
StructurePlain or creped (depending on grade)
Binder ContentBinder-free (selected grades)
Filtration TypeQualitative
Pore StructureGrade-dependent (coarse to fine)
Available SizesMultiple diameters (e.g., 15 mm to 500 mm and sheet formats)

Comparison with Other Filter Paper Types

FeatureQualitative Filter Papers (VWR)Quantitative (Ashless) Filter Papers
Ash Content~0.06%≤0.01%
Use CaseGeneral filtrationGravimetric analysis
Cost EfficiencyHighModerate
Filtration AccuracySuitable for routine workHigh precision required
ApplicationsRoutine labs, education, industryAnalytical chemistry, research

Unique Advantages

  • Comprehensive Grade Portfolio
    Enables precise matching of filtration requirements across diverse applications.
  • Reliable Performance in Routine Workflows
    Ideal for laboratories requiring consistent, repeatable filtration without the cost of ashless papers.
  • Versatility Across Industries
    Suitable for academic, clinical, food, pharmaceutical, and industrial environments.
  • Optimized for Both Speed and Retention
    Wide range of grades ensures flexibility between rapid filtration and fine particle retention.
  • Trusted VWR Quality
    Backed by rigorous manufacturing standards and global laboratory acceptance.

Ordering Information

Catalog No.GradeSize / FormatPack SizePurpose / Use
516-034940155 mm100/pkCoarse filtration of large precipitates (e.g., iron, aluminium hydroxides); metallurgical analysis
516-035040170 mm100/pkCoarse filtration of large precipitates; metallurgical analysis
516-028240170 mm × 80 m (Roll)1 rollContinuous filtration for coarse precipitates and industrial workflows
516-0351401125 mm100/pkCoarse filtration of voluminous precipitates
516-0283402150 mm100/pkGeneral qualitative analysis; sulphides; dairy fat determination
516-0289403150 mm100/pkFine filtration for pharmaceuticals, clinical labs, chromatography, protein-free filtrations
516-080041075 mm100/pkFine filtration of difficult precipitates; analytical chemistry; wine clarification
516-080141090 mm100/pkFine filtration of difficult precipitates and analytical samples
516-0802410110 mm100/pkFine filtration for analytical and chemical applications
516-0803410125 mm100/pkFine filtration of heavy or dense precipitates
516-0804410150 mm100/pkFine filtration and clarification of solutions
516-0805410185 mm100/pkFine filtration for difficult separations
516-081041315 mm100/pkRoutine laboratory filtration; general chemistry applications
516-081141342.5 mm100/pkRoutine lab work and student laboratory use
516-081241355 mm100/pkGeneral filtration for routine laboratory tasks
516-081341375 mm100/pkRoutine filtration of inorganic precipitates
516-081441390 mm100/pkGeneral-purpose filtration in chemistry labs
516-0815413110 mm100/pkRoutine analytical filtration
516-0816413125 mm100/pkGeneral filtration for laboratory and academic use
516-0817413150 mm100/pkRoutine filtration and sample clarification
516-0818413185 mm100/pkMedium retention filtration for general lab use
516-0819413205 mm100/pkRoutine filtration of precipitates
516-0820413240 mm100/pkGeneral laboratory filtration applications
516-083041555 mm100/pkRapid filtration of coarse and gelatinous precipitates (e.g., metal hydroxides)
516-083141575 mm100/pkCoarse filtration of bulky precipitates
516-083241590 mm100/pkFast filtration of gelatinous materials
516-0833415110 mm100/pkRapid filtration for heavy precipitates
516-0834415125 mm100/pkCoarse filtration in chemical analysis
516-0835415150 mm100/pkFast filtration of metal hydroxides and carbonates
516-0836415185 mm100/pkCoarse filtration of high-load samples
516-0837415205 mm100/pkRapid filtration for bulky precipitates
516-0838415250 mm100/pkLarge-scale coarse filtration
516-0839415330 mm100/pkHigh-volume filtration of coarse materials
516-082141790 mm50/pkVery fast filtration where fine particle retention is not required
516-0822417110 mm50/pkRapid filtration for large-volume samples
516-0823417125 mm50/pkFast filtration in routine workflows
516-0824417150 mm50/pkHigh-speed filtration of non-critical samples
516-0825417185 mm50/pkRapid filtration for coarse suspensions
516-0826417205 mm50/pkFast filtration for industrial or routine lab use
516-0827417250 mm50/pkLarge-format rapid filtration
516-0828417330 mm50/pkHigh-throughput filtration applications
516-0829417500 mm50/pkLarge-scale rapid filtration processes
516-0309600420 × 520 mm500/pkRoutine laboratory filtration in universities, hospitals, and general labs
516-0880600460 × 570 mmGeneral-purpose filtration for large-format laboratory applications


VWR® Qualitative Filter Papers offer a dependable and versatile solution for routine laboratory filtration needs. With their high-purity cellulose composition, low ash content, and broad selection of grades, they support efficient and reproducible filtration across a wide range of analytical and industrial applications.

Their adaptability, cost-effectiveness, and consistent performance make them an essential consumable for laboratories seeking reliable qualitative filtration without compromising workflow efficiency.

  • Grade:   Grade 401 Grade 402 Grade 403 Grade 410 Grade 413 Grade 415 Grade 417 Grade 600
  • Size:   Single sheets, 460×570 mm ,100/pk 55 mm, circles, 100/pk 70 mm, circles, 100/pk 70 mm × 80 m sheet, 1/Roll 125 mm, circles, 100/pk 150 mm, circles, 100/pk 75 mm, circles, 100/pk 90 mm, circles, 100/pk 110 mm, circles, 100/pk 185 mm, circles, 100/pk 15 mm, circles, 100/pk 42.5 mm, circles, 100/pk 205 mm, circles, 100/pk 240 mm, circles, 100/pk 250 mm, circles, 100/pk 330 mm, circles, 100/pk 90 mm, circles, 50/pk 110 mm, circles, 50/pk 125 mm, circles, 50/pk 150 mm, circles, 50/pk 185 mm, circles, 50/pk 205 mm, circles, 50/pk 250 mm, circles, 50/pk 330 mm, circles, 50/pk 500 mm, circles, 50/pk 420×520 mm sheets, 500/pk

Accessory Products


Add a Review

Rate this Product  
Name *
Email *

Your Review *
34113





0

0  Reviews
(0) 
(0) 
(0) 
(0) 
(0) 

Customer Review