BEHR Behrotest® KEX 2000 F/TK Complete Soxhlet Extraction System (2000 mL Extractor with 5000 mL Round Flask and Titanium Condenser)
Catalog No :
CAS Number :
Brand :
In Stock
Sample Capacity: 1 Sample
Specifications:
| Application | Determination of Total Fats | Warranty | 1 Year |
| Storage Temperature | Ambient | ||
| Product Type | Laboratory Equipment | ||
| Product Brand | Behr Labor-Technik | ||
| Product Grade | Analytical grade | ||
The BEHR Behrotest® KEX 2000 F/TK Soxhlet Extraction System represents the ultimate solution for large-volume fat and solvent extractions, designed to meet the demanding requirements of modern analytical, industrial, and research laboratories.
This complete system is engineered for high-capacity extraction applications involving food, feed, environmental, and chemical samples. It features a 2000 mL glass extractor, a 5000 mL round-bottom flask, and a robust titanium condenser for superior heat resistance, efficient solvent recovery, and long-term operational durability.
Equipped with an integrated magnetic stirrer and infinitely variable heating control, the KEX 2000 F/TK provides precise process regulation for consistent and reproducible extraction results. Designed with BEHR’s hallmark focus on safety, performance, and ease of use, it also supports acid digestion pre-treatment when used with BEHR hydrolysis units, enabling total fat determination according to the Weibull and Stoldt method.
Key Features
- High-Volume Soxhlet Extraction: Ideal for large-scale fat, oil, and organic residue analyses with a 2000 mL extractor and 5000 mL flask.
- Titanium Condenser: Ensures excellent corrosion resistance, efficient condensation, and extended lifespan, even with aggressive solvents.
- Infinitely Variable Heating Regulation: Provides full control of extraction temperature and solvent evaporation rates.
- Integrated Magnetic Stirrer: Promotes homogeneous heating and solvent mixing for precise, repeatable results.
- Böckerhoff-Type Lifting Tube: Guarantees uniform extraction across the entire sample matrix.
- Stopcock Model (F/TK): Allows direct solvent discharge after extraction, eliminating the need for post-extraction distillation.
- Complete Extraction Setup: Includes reaction vessels, spacers, condensers, and holders for secure operation.
- Practical Stand and Holders: Facilitate safe condenser handling and adapter fixation between extractions.
- Compatible with BEHR Hydrolysis Units: Enables combined hydrolysis and extraction for total fat quantification (Weibull & Stoldt).
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | KEX 2000 F/TK |
| Article Number | B00722652 |
| Extractor Volume | 2000 mL |
| Flask Volume | 5000 mL (Round-Bottom) |
| Condenser Type | Titanium Condenser |
| Heating Power | 800 W |
| Integrated Magnetic Stirrer | Yes |
| Controller | No |
| Sample Positions | 1 |
| Power Regulation | Infinitely Variable |
| Capacity | 5,000 mL |
| Packaging Quantity | 1 |
Areas of Use
- Food Analysis: Determination of fat, oil, and extractable matter.
- Feed & Agricultural Industry: Extraction of fats and oils in animal feed, seeds, and plant materials.
- Beverage Industry: Caffeine and residue extractions from coffee and tea.
- Environmental Analysis: Extraction of PCBs, dioxins, pesticides, and hydrocarbons from soil and sludge.
- Chemical & Plastics Industry: Testing for extractable components, residual resin, and additives.
- Research Laboratories: Advanced solvent extraction studies and method development in analytical chemistry.
Analytes and Parameters
- Extract content
- Total fat and free fat
- Oils and lipids
- PCBs, pesticides, dioxins
- Bound and non-fat matter
- Chloride and residual resin content
- Caffeine, tein, and fibrous components
Typical Sample Materials
- Soils and sediments
- Meat and fish products
- Feed and agricultural raw materials
- Coffee, tea, and plant-based samples
- Dairy and milk products
- Sludge, compost, and cellulose-based materials
- Oils, seeds, and processed foods
Benefits
- Reliable and reproducible extraction performance
- Excellent solvent recovery and condensation efficiency
- Robust titanium components for maximum corrosion resistance
- Large capacity suited for high-throughput analytical labs
- Reduced need for post-processing due to integrated stopcock
- Safe and user-friendly operation with ergonomic design
- Compatible with hydrolysis pre-treatment for total fat analysis
The BEHR Behrotest® KEX 2000 F/TK Soxhlet Extraction System delivers unmatched performance for large-scale solvent extraction applications across diverse industries. With its titanium condenser, infinitely variable heating, and magnetic stirring system, it ensures consistent, precise, and efficient extraction of fats, oils, and organic residues from complex matrices. Whether for food quality assurance, environmental testing, or research applications, the KEX 2000 F/TK stands as the benchmark for reliability, capacity, and analytical precision in Soxhlet extraction.
0