Specifications:
| Application | Chemiluminescent Immunoassay |
| Storage Temperature | 2-8°C |
| Product Type | CLIA Reagent |
| Product Brand | Autobio Diagnostics |
| Product Grade | Medical grade |
The AutoLumo CLIA Vitamin Marker Microparticles provides high-precision chemiluminescent immunoassay (CLIA) reagents for the quantitative determination of vitamins and bone metabolism-related markers in human serum or plasma.
Developed for use with AutoLumo CLIA Analyzers, these magnetic microparticle-based reagents offer high sensitivity, accuracy, and reproducibility for assessing key vitamins including 25-OH Vitamin D, Folate, Vitamin B12, and Osteocalcin (OST).
All assays are CE marked and meet international diagnostic standards, ensuring consistent and reliable performance in clinical, nutritional, and metabolic laboratories.
Key Features
- High Analytical Sensitivity: Detects low concentrations of vitamins and bone metabolism markers.
- Magnetic Microparticle CLIA Technology: Ensures precise binding and stable chemiluminescent signal output.
- Comprehensive Diagnostic Range: Supports bone metabolism, vitamin deficiency, and anemia-related testing.
- Automation Ready: Fully compatible with AutoLumo CLIA Analyzers.
- CE Marked Kits: Certified for routine diagnostic use.
- Reliable and Reproducible Results: Excellent correlation with established reference methods.
- Long Shelf Life: Stable reagent formulation for consistent performance.
Product Range
Bone Metabolism Markers
| Code | Marker | Description | Pack Size | CE Mark |
|---|---|---|---|---|
| CMS0402 | 25-OH Vitamin D | 25-Hydroxy Vitamin D CLIA Microparticles | 100 Tests | Yes |
| — | 25-OH Vitamin D (II) | 25-Hydroxy Vitamin D CLIA Microparticles II | 100 Tests | — |
| CMS0102 | OST | Osteocalcin CLIA Microparticles | 100 Tests | Yes |
Applications:
- Evaluation of vitamin D deficiency and disorders of calcium-phosphate metabolism.
- Osteocalcin measurement for assessing bone formation and turnover.
- Screening and monitoring of osteoporosis, osteopenia, and other metabolic bone diseases.
Anemia & Nutritional Markers
| Code | Marker | Description | Pack Size | CE Mark |
|---|---|---|---|---|
| CMS0202 | Folate | Folate CLIA Microparticles | 100 Tests | Yes |
| CMS0302 | Vitamin B12 | Vitamin B12 CLIA Microparticles | 100 Tests | Yes |
Applications:
- Folate and Vitamin B12 testing for evaluation of megaloblastic anemia and nutritional deficiencies.
- Supports differential diagnosis of anemia due to vitamin deficiency.
- Monitors treatment response in B12 and folate supplementation therapies.
Clinical Applications
- Bone Metabolism: Assessment of vitamin D and osteocalcin for bone health and calcium balance.
- Nutritional Deficiency Detection: Evaluation of folate and vitamin B12 levels to diagnose anemia and malnutrition.
- Preventive Medicine: Screening for vitamin-related metabolic disorders.
- Endocrine and Metabolic Research: Quantitative hormone and vitamin correlation studies.
Performance Characteristics
- Detection Method: Chemiluminescent Immunoassay (CLIA)
- Technology: Magnetic Microparticle-Based Sandwich Immunoassay
- Sample Type: Human Serum or Plasma
- Precision: Coefficient of Variation (CV) ≤ 10%
- Storage Conditions: 2–8°C, protected from light
- Shelf Life: 12 months from manufacturing date
Unique Advantages
- Comprehensive vitamin and bone metabolism testing on one analyzer platform.
- Automation compatible — optimized for AutoLumo CLIA analyzers.
- CE-certified reagents suitable for accredited clinical use.
- High sensitivity and stability for accurate detection of vitamin deficiencies.
- Reliable performance for laboratories conducting nutritional and metabolic diagnostics.
The AutoLumo CLIA Vitamin Marker Microparticles delivers a complete panel of high-sensitivity, fully automated CLIA reagents for the detection of key vitamin and bone metabolism markers.
With CE-marked quality, magnetic microparticle technology, and robust analytical performance, this series ensures dependable results for nutritional evaluation, anemia diagnosis, and metabolic health monitoring.
A preferred choice for clinical laboratories, diagnostic centers, and research institutions using AutoLumo CLIA Analyzers for precise and efficient vitamin assessment.
- Target Marker: 25-Hydroxy Vitamin D (25-OH Vitamin D) 25-Hydroxy Vitamin D (25-OH Vitamin D (II)) Osteocalcin (OST ) Vitamin B12 Folic Acid (Folate)
0