Invitrogen™ ProcartaPlex™ Human Inflammation Panel, 20plex
Catalog No :
CAS Number :
Brand :
In Stock
Cytokines: GM-CSF [44], IFN alpha [48], IFN gamma [43], IL-1 alpha [62], IL-1 beta [18], IL-4 [20], IL-6 [25], IL-8 [27], IL-10 [28], IL-12p70 [34], IL-13 [35], IL-17A (CTLA-8) [36], TNF alpha [45]
Chemokines: IP-10 (CXCL10) [22], MCP-1 (CCL2) [51], MIP-1 alpha (CCL3) [12], MIP-1 beta (CCL4) [47]
Cell adhesion and inflammatory response: ICAM-1 [73], CD62E (E-selectin) [77], CD62P (P-Selectin) [55]
Specifications:
Application | Protein Assays & Analysis | ||
Storage Temperature | 2-8°C | ||
Product Type | Assay Kits | Forms | Kit with Various components |
Product Brand | Thermo Fisher Scientific™ | ||
Product Grade | Molecular Biology | ||
The Invitrogen™ ProcartaPlex™ Human Inflammation Panel, 20-Plex, is a highly efficient multiplex immunoassay designed for the simultaneous quantification of 20 human inflammatory protein targets. Utilizing Luminex™ xMAP™ technology, this panel allows for precise and reproducible cytokine and chemokine profiling, enabling researchers to better understand immune responses and inflammatory processes.
Key Features:
- Comprehensive Inflammatory Profiling:
- Measures 20 analytes in a single assay, including cytokines, chemokines, and adhesion molecules such as:
- Cytokines: GM-CSF, IFN-α, IFN-γ, IL-1α, IL-1β, IL-4, IL-6, IL-8, IL-10, IL-12p70, IL-13, IL-17A, TNF-α.
- Chemokines: IP-10 (CXCL10), MCP-1 (CCL2), MIP-1α (CCL3), MIP-1β (CCL4).
- Adhesion Molecules: ICAM-1, CD62E (E-selectin), CD62P (P-selectin).
- Measures 20 analytes in a single assay, including cytokines, chemokines, and adhesion molecules such as:
- High Sensitivity and Specificity:
- Uses biotinylated detection antibodies and streptavidin-RPE conjugates to ensure robust and accurate detection.
- Small Sample Volume:
- Requires only 25 μL of serum or plasma or 50 μL of cell culture supernatant per well.
- Luminex™ Platform Compatible:
- Works seamlessly with MAGPIX™, FLEXMAP 3D™, and Luminex 200™ systems for high-throughput analysis.
- Fast and Efficient Protocol:
- Achieve results in as little as 4 hours, saving time compared to traditional ELISA workflows.
- Validated Multiplex Panel:
- Each panel is rigorously tested for combinability, interference, and cross-reactivity, ensuring precision and reliability.
Specifications:
Feature | Details |
---|---|
Targets | 20 cytokines, chemokines, and adhesion molecules |
Detection Method | Fluorescence (R-PE conjugate) |
Sample Types | Serum, Plasma, Cell Culture Supernatants |
Sample Volume | 25 μL (serum/plasma), 50 μL (CCS) |
Assay Sensitivity | See Certificate of Analysis |
Platform Compatibility | Luminex™ Instruments (MAGPIX™, FLEXMAP 3D™, Luminex 200™) |
Format | Multiplex Kit |
Unit Size | 96 tests |
Storage Conditions | 2°C to 8°C |
Shipping Conditions | Wet Ice |
Applications:
- Inflammatory Disease Research:
- Profile pro- and anti-inflammatory mediators in conditions such as autoimmune disorders, sepsis, and chronic inflammation.
- Cytokine Storm Studies:
- Investigate cytokine release syndrome (CRS) in infectious and immune-related diseases.
- Cancer Research:
- Examine the role of inflammatory cytokines and chemokines in tumor microenvironments.
- Drug Development:
- Assess the efficacy of immunomodulatory therapies by monitoring inflammatory markers.
- Biomarker Discovery:
- Identify inflammatory biomarkers for diagnostics or therapeutic targets.
Advantages:
- Comprehensive Data from Small Samples:
- Simultaneously quantifies 20 analytes, maximizing data output while minimizing sample consumption.
- Fast and Reproducible:
- Highly validated panel ensures consistent results in less than 4 hours.
- Ease of Use:
- Preconfigured kit contains all necessary reagents and protocols for streamlined setup and execution.
- High-Throughput Compatibility:
- Designed for use with Luminex platforms, enabling large-scale studies and efficient data acquisition.
- Wide Sample Compatibility:
- Suitable for diverse sample types, including serum, plasma, and cell culture supernatants.
Protocol Overview:
- Prepare Samples and Reagents:
- Dilute samples and reconstitute lyophilized standards.
- Add Capture Beads:
- Add the Capture Bead Mix to each well of the provided black 96-well plate.
- Incubate with Samples:
- Add 25–50 μL of prepared sample to the beads and incubate.
- Add Detection Antibodies:
- Wash the beads and incubate with the Biotinylated Detection Antibody Mix.
- Add Streptavidin-RPE:
- Incubate the beads with Streptavidin-PE to complete the sandwich assay.
- Analyze:
- Wash the beads, resuspend in the Reading Buffer, and analyze using a Luminex-compatible instrument.
Kit Contents:
- Human Standard Mixes (A, B, F), lyophilized.
- Capture Bead Mix (1X).
- Biotinylated Detection Antibody Mix (50X).
- Streptavidin-PE (1X).
- Wash Buffer (10X).
- Reading Buffer (1X).
- Universal Assay Buffer (1X).
- Detection Antibody Diluent (1X).
- Black flat-bottom 96-well plate with adhesive film.
Ordering Information:
Catalog Number | Description | Unit Size |
---|---|---|
EPX200-12185-901 | ProcartaPlex™ Human Inflammation Panel, 20-Plex | 96 tests |
Storage and Handling:
- Store at 2°C to 8°C.
- Avoid repeated freeze-thaw cycles.
Related Products:
- ProcartaPlex™ High Sensitivity Panels: For ultra-low cytokine detection.
- Luminex™ Instruments: Compatible platforms for assay analysis.
- Customizable ProcartaPlex Panels: Tailored solutions for specific research needs.
The Invitrogen™ ProcartaPlex™ Human Inflammation Panel, 20-Plex, is a powerful tool for high-throughput cytokine and chemokine profiling. Its precision, efficiency, and compatibility with Luminex platforms make it an indispensable resource for inflammation research and biomarker discovery.