Ultrameter

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Conductivity: 0–9999 µS/cm 10–200 mS/cm in 5 autoranges
Resistivity: 10 KΩ–30 MΩ
TDS: 0–9999 ppm 10–200 ppt in 5 autoranges
pH: 0–14 pH
ORP: ±999 mV
Free Chlorine Equivalent: 0.00–9.99 ppm
350 ≤ ORPmV < 725 and 0.0 ≤ pH < 9.9
725 ≤ ORPmV < 825 and 0.0 ≤ pH < 8.9
Temperature: 0–71°C/32–160°F

Conditions générales
Garantie satisfait ou remboursé de 30 jours
Expédition : 2-3 jours ouvrables

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application Water Quality Analysis, Electrochemistry Warranty 1 Year
    Storage Temperature Ambient
    Product Type Portable Meters
    Product Brand Myron L
    Product Grade Analytical grade

    We are proud of the trust our handheld water quality instruments and monitor/controllers have earned in the past. Our product line has evolved to a new level of outstanding performance and value in analytical instruments: the Ultrameter II™ series. While priced like affordable single-parameter instruments, the Ultrameter II does the job of up to seven instruments.

    Accuracy You Can Trust

    Both Ultrameter II models deliver performance of ±1% of reading (not merely full scale). This high level of accuracy has been achieved through advanced four-electrode conductivity cell technology, a unique pH/ORP sensor and powerful microprocessor-based circuitry. With displayed values of up to 9999, the full four-digit LCD ensures resolution levels never before possible in such affordable instruments. Factory calibrated with NIST traceable solutions, each Ultrameter II may be supplied with both certification of traceability and NIST traceable solutions for definitive calibration.

    Innovative Engineering

    The Ultrameter II is a prime example of how high-tech engineering can greatly simplify and streamline a task. Whether in the lab, industrial plant, or in a remote field location, merely:

    • Fill the cell cup
    • Push a parameter key
    • Take the reading

    Temperature compensation and range selection are both rapid and automatic. The Ultrameter II is a true one-hand operation instrument.

    Easy to Calibrate

    All calibrations are quickly accomplished by pressing the ▲ or ▼ keys to agree with our NIST traceable Standard Solution. When calibration is necessary, display prompts simplify pH calibration and make sure the correct buffer is being used. Plus, all parameters (excluding factory-set temperature) have an internal electronic setting that can be used for field calibration and as a check on pH/ORP sensor life.

    NEW! FCE™FAC Readings

    The Myron L® Company FCE function reports FAC quickly and accurately by measuring ORP, the chemical characteristic of chlorine that directly reflects its effectivity, cross referenced with pH. Both DPD kits and colorimeters may tell the user the FAC value of the sample in the test tube, but since the chemistry of that sample is quite different from the source water being analyzed, the results are imprecisely related to actual disinfection power. The Myron L® Company FCE function measures the real, unaltered chemistry of source water, including moment-to-moment changes in that chemistry.

    High Performance at a Low Cost

    Beyond their affordable purchase price, Ultra-Fast, Ultra-Easy, Ultra- Powerful Ultrameter IIs save both time and money. Measure for measure, Ultrameter IIs give you a better return on your investment than any other handheld instrument. To see for yourself, contact your distributor or the Myron L® Company today.

    ULTRAMETER II Features & Benefits:

    • 3 solution standards for greatest accuracy in diverse applications.
    • Fully automatic temperature compensation.
    • User adjustable temperature compensation (up to 9.99%/°C) which also allows TC to be disabled for applications requiring non-compensated readings.
    • User adjustable conductivity/TDS conversion ratio for greater accuracy when measuring solutions not contained in the microprocessor.
    • Auto-shutoff maximizes the life of the single 9V battery to more than 100 hours/5000 tests.
    • Non-volatile microprocessor provides data back-up, even when the battery is changed. This assures all calibrations and memory data will be retained.
    • Extended life pH/ORP sensor is user replaceable in the field.


    Ultrameter II™ 6PFCᴱ & 4P Specifications:

    Display: 4 Digit Liquid Crystal Display
    Dimensions: L x W x H 196 x 68 x 64 mm/7.7 x 2.7 x 2.5 inches
    Weight: 352 g/12.4 oz.
    Case/conductivity cell material: VALOX*
    Cell capacities pH/ORP: 1,2 ml/0.04 oz. Cond/TDS/Res: 5 ml/0.2 oz.
    Power: 9V alkaline battery
    Battery life: >100 hours (5000 readings)
    Operating/storage temperature: 0 – 55°C/32 – 132°F
    Protection Ratings: IP67/NEMA 6 (waterproof to 1 meter/3 feet)
    EMI/EMC Ratings (Conformité Européenne): IEC 61326-1: 2020; CISPR 11: 2015 +A1: 2016 +A2: 2019; IEC 61000-4-2: 2008; IEC 61000-4-3: 2010; IEC 61000-4-8: 2009; (EU) 2015/863 (RoHS3): +(EU) 2024/232
    *™Sabic Innovative Plastics

    Functional Specifications:

    ConductivityRanges: 0–9999 μS/cm; 10–200 mS/cm; in 5 autoranges
    Resolution: 0.01(<100 μS); 0.1(<1000 μS); 1(<10 mS); 0.01(<100 mS); 0.1(<200 mS)
    Accuracy: ±1% of reading
    Auto Temperature Compensation: 0–71°C / 32–160°F
    Adjustable Temperature Compensation to 25°C: 0–9.99%/°C
    Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
    Adjustable Conductivity/TDS Ratio Factor: 0.20–7.99
    TDSRanges: 0–9999 ppm; 10–200 ppt; in 5 autoranges
    Resolution: 0.01(<100 ppm); 0.1(<1000 ppm); 1(<10 ppt); 0.01(<100 ppt); 0.1(<200 ppt)
    Accuracy: ±1% of reading
    Auto Temperature Compensation: 0–71°C / 32–160°F
    Adjustable Temperature Compensation to 25°C: 0–9.99%/°C
    Conductivity/TDS Ratios Preprogrammed: KCl, 442*, NaCl
    Adjustable Conductivity/TDS Ratio Factor: 0.20–7.99
    ResistivityRanges: 10 KΩ–30 MΩ
    Resolution: 0.01(<100 KΩ); 0.1(<1000 KΩ); 0.1(>1 MΩ)
    Accuracy: ±1% of reading
    Auto Temperature Compensation: 0–71°C / 32–160°F
    Adjustable Temperature Compensation to 25°C: 0–9.99%/°C
    pHRanges: 0–14 pH
    Resolution: 0.01 pH
    Accuracy**: ±0.01 pH
    Auto Temperature Compensation: 0–71°C / 32–160°F
    ORPRanges: ±999 mV
    Resolution: 1 mV
    Accuracy**: ±1 mV
    Free Chlorine FCE™Ranges: 0.00–9.99 ppm when 350≤ORPmV<725 and 0.0≤pH<9.9 and when 725≤ORPmV<825 and 0.0≤pH<8.9
    Resolution: 0.01 ppm
    Accuracy**: <1.00ppm ±0.3ppm and ≥1.00ppm ±0.2ppm
    Auto Temperature Compensation: 0–71°C / 32–160°F
    TemperatureRanges: 0–71°C / 32–160°F
    Resolution: 0.1°C/F
    Accuracy: ±0.1°C
    *442 Natural Water Standard™ Myron L® Company
    **EM Susceptibility: When measuring 4.00 pH Buffer in 3.5 molar KCl:
            ± 0.2 pH in the presence or RF fields ≥ 3 V/m.
            ± 0.37 pH in the presence of RF fields ≥ 3 V/m at 300 MHz (± 30 MHz) and 625 MHz (± 50 MHz ).

    Product Specification not found.


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    9866





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review




    Showing 0 Of 0