Sample Cell Compatibility: Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps
Sample Requirements; 25 mm sample cell: 20 mL minimum
Source Lamp: Tungsten Lamp
Range: 0 - 4000 NTU

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Application Water Quality Analysis Warranty 1 Year
    Storage Temperature Ambient
    Product Type Benchtop meters
    Product Brand Hach
    Product Grade Analytical grade

    Trusted High-Range Turbidity Measurement. Simplified.

    The Hach® TL2300 EPA Laboratory Turbidimeter is engineered for precision, reliability, and ease of use in high-range turbidity applications. Built on Hach’s proven optical technology, this advanced benchtop instrument delivers dependable nephelometric measurements in accordance with EPA Method 180.1, making it ideal for regulatory compliance in water and wastewater laboratories.

    Designed with operators in mind, the TL2300 features a vibrant 17.8 mm full-colour touchscreen, an intuitive interface, and guided workflows that simplify calibration, data logging, and result interpretation. Whether you're testing drinking water, surface water, or effluent, the TL2300 ensures accurate results even under variable environmental conditions.

    Key Features:

    • EPA Compliant Performance
      Fully meets U.S. EPA Method 180.1 for turbidity measurement, ensuring accurate and regulatory-accepted results.
    • Smart Stabilization Technology
      Automatically captures readings only when sample stability is achieved, eliminating subjectivity and reducing operator error.
    • User-Friendly Touchscreen Interface
      A large, full-colour touch display enhances usability with guided instructions, real-time visual cues, and accessible settings.
    • Comprehensive Data Logging
      Stores up to 2,000 logs, including readings, verifications, and calibrations, supporting full traceability and GLP compliance.
    • Flexible USB Connectivity
      Equipped with dual USB-A ports for seamless data export, printer connectivity, barcode scanning, and keyboard input.
    • Enhanced Accuracy Across Wide Ranges
      Capable of measuring 0 to 4000 NTU, with options for Ratio On/Off modes and EBC unit support.

    Applications:

    • Groundwater Monitoring
    • Municipal Water Treatment
    • Membrane Protection Systems
    • QA/QC Laboratory Analysis
    • Surface Water and Environmental Surveillance

    Technical Specifications:

    AttributeSpecification
    Measurement MethodNephelometric
    Measuring Range0 – 4000 NTU (Ratio On), 0 – 40 NTU (Ratio Off); EBC: 0 – 980 (Ratio On)
    Accuracy±2% of reading + 0.01 NTU (0–1000 NTU); ±5% of reading (1000–4000 NTU)
    Repeatability±1% of reading or 0.01 NTU (whichever is greater)
    Stabilization Time30 min (Ratio On), 60 min (Ratio Off) after startup
    Sample VolumeMinimum 20 mL in 25 mm sample cell
    Sample Cell Compatibility95 x 25 mm round borosilicate glass with rubber-lined screw caps
    Display17.8 mm full-colour touchscreen
    Data Logging2000 total logs (readings, verifications, calibrations)
    Light SourceTungsten filament lamp
    Power Requirements100 – 240 V AC, 50/60 Hz, 3.4 A
    Interfaces2 x USB-A ports
    Operating Temp Range0 – 40 °C
    Storage Conditions-20 to 60 °C, max. 80% RH (non-condensing)
    CertificationsCE, KC, RCM
    ComplianceEPA Method 180.1
    Weight3.0 kg
    Dimensions (H x W x D)153 mm x 395 mm x 305 mm

    What's Included:

    • TL2300 Turbidimeter Instrument
    • Stablcal® Calibration Kit
    • Gelex Secondary Turbidity Standardization Kit
    • USEPA Filter Assembly
    • Six 1-inch (30 mL) Sample Cells with Caps
    • Silicone Oil and Oiling Cloth
    • Power Supply and Cord
    • USB Ports
    • Dust Cover
    • Multilingual User Manual

    Unique Advantages:

    • Faster Calibration & Verification
      The improved interface and guided procedures reduce setup time and training needs.
    • Traceability and Compliance
      Built-in sample ID tracking and robust data storage help meet Good Laboratory Practice (GLP) standards.
    • Field-Compatible Lab Instrument
      Though designed for benchtop use, the rugged build and flexible input/output make it suitable even in semi-field conditions.
    • Minimal Maintenance
      Self-diagnostic tools and reliable lamp design reduce downtime and maintenance intervals.

    The Hach TL2300 EPA Turbidimeter is the ideal solution for laboratories and facilities needing fast, accurate, and regulatory-compliant turbidity measurements—simplifying testing without compromising precision.

    Product Specification not found.
    Resources file not found.


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    21256





    0

    0  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review




    Showing 0 Of 0