VWR® BDH Ethyl Acetate ≥99.5%, Analar Normapur® Acs, Reag. Ph. Eur. Analytical Reagent, 2.5L

Catalog No :

CAS Number :

Brand :

Availability :

In Stock

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

    This combination does not exist.

    Place Inquiry

    This combination does not exist.

    Specifications:
    Storage Temperature Ambient
    Product Type Laboratory Chemical Forms Liquid
    Product Brand VWR
    Product Grade Analytical grade Formula CH₃COOC₂H₅

    The VWR® Ethyl Acetate ≥99.5%, Analar Normapur® ACS, Reag. Ph. Eur. is a high-purity analytical reagent-grade solvent, meeting the stringent standards of:

    • ACS (American Chemical Society) standards
    • Reag. Ph. Eur. (European Pharmacopoeia) specifications
    • Analar Normapur® quality criteria

    This analytical-grade ethyl acetate is widely used in chemical analysis, chromatography, extraction processes, and synthesis applications, making it an essential reagent in pharmaceutical, industrial, and research laboratories.

    Key Properties & Specifications

    PropertyDetails
    Chemical FormulaC₄H₈O₂
    Molecular Weight88.11 g/mol
    Purity≥99.5%
    CAS Number141-78-6
    Boiling Point76-78°C
    Density0.902 g/mL at 20°C
    SolubilitySlightly soluble in water, miscible with most organic solvents
    GradeAnalytical Reagent (ACS, Reag. Ph. Eur., Analar Normapur®)
    AppearanceClear, colorless liquid with a fruity odor
    Storage ConditionsStore in a tightly sealed container at a well-ventilated place away from heat sources

    Applications & Use Cases

    1. Chromatography & Analytical Testing

    Primary Use:

    • Solvent in High-Performance Liquid Chromatography (HPLC) and Gas Chromatography (GC)
    • Used as a mobile phase in Thin Layer Chromatography (TLC)
    • Suitable for sample preparation and purification techniques

    Practical Example:

    A pharmaceutical quality control lab uses VWR® Ethyl Acetate in HPLC analysis to test for impurities and degradation products in drug formulations. Due to its high purity, it ensures accurate, interference-free results in analytical separations.

    2. Pharmaceutical & Chemical Synthesis

    Primary Use:

    • Serves as a reaction solvent for esterification and organic synthesis
    • Used in extraction and purification of active pharmaceutical ingredients (APIs)
    • Essential for solvent-mediated crystallization of pharmaceutical compounds

    Practical Example:

    A research laboratory in medicinal chemistry uses ethyl acetate to extract and purify synthetic drug intermediates. Its ability to selectively dissolve organic compounds while leaving behind unwanted byproducts makes it ideal for purification processes.

    3. Sample Preparation & Liquid-Liquid Extraction (LLE)

    Primary Use:

    • Used in extraction of organic compounds from aqueous solutions
    • Applied in toxicology and forensic science for isolating drugs, pesticides, and metabolites
    • Preferred solvent for preparing extracts for mass spectrometry (MS) analysis

    Practical Example:

    A forensic toxicology lab uses VWR® Ethyl Acetate for liquid-liquid extraction (LLE) of drug residues from biological samples before analysis via Gas Chromatography-Mass Spectrometry (GC-MS). Its low polarity allows for efficient separation of hydrophobic substances from aqueous matrices.

    4. Industrial Applications & Quality Control

    Primary Use:

    • Solvent in coatings, adhesives, and printing inks manufacturing
    • Used in flavor and fragrance production
    • Key solvent in paint and varnish removers

    Practical Example:

    A cosmetic manufacturer uses ethyl acetate in fragrance formulation, as it helps dissolve aromatic compounds while evaporating quickly, leaving behind only the desired scent.

    5. Histology & Tissue Processing in Life Sciences

    Primary Use:

    • Used in histological staining protocols
    • Facilitates tissue dehydration in slide preparation
    • Acts as a solvent for fat extraction in food analysis

    Practical Example:

    A pathology lab incorporates ethyl acetate in tissue processing to dehydrate samples before embedding them in paraffin, ensuring clear, high-resolution microscopic examination of cell structures.

    Advantages of VWR® Ethyl Acetate ≥99.5%, Analar Normapur®

    High Purity & Low Contaminants – Ensures accurate and reliable analytical results

    Versatile Solvent – Suitable for chromatography, synthesis, extraction, and histology

    Meets Stringent Standards – Complies with ACS, Reag. Ph. Eur., and Analar Normapur® quality requirements

    Low Water Content – Prevents interference in sensitive chemical and analytical reactions

    Fast Evaporation Rate – Ideal for quick-drying applications in coatings, adhesives, and fragrance industries

    Storage & Safety Considerations

    🔹 Storage Recommendations:

    • Keep container tightly closed in a cool, well-ventilated area.
    • Store away from heat sources, open flames, and strong oxidizing agents.

    🔹 Safety Precautions:

    • Highly flammable liquid and vapor – Keep away from ignition sources.
    • Use in a fume hood to prevent inhalation of vapors.
    • Wear protective gloves and goggles when handling.

    🔹 Disposal Guidelines:

    • Dispose of in accordance with local environmental regulations.
    • Do not discharge into drains, water sources, or soil.

    The VWR® Ethyl Acetate ≥99.5%, Analar Normapur® ACS, Reag. Ph. Eur. is a high-purity solvent trusted for analytical, pharmaceutical, industrial, and life science applications. With its versatility, reliability, and compliance with global purity standards, it remains an essential reagent for laboratories requiring precision, efficiency, and safety in their chemical processes.

    Specification Test Results

    Assay (on anhydrous substance)Min. 99.5 %
    IR SpectrumPasses test
    Organic impuritiesPasses test
    AcidityMax. 0.0006 meq/g
    Boiling point76.0 - 77.5 °C
    ColourationMax. 10 APHA
    Density (20/4)0.899 - 0.901
    Density (20/20)0.901 - 0.904
    Substances coloured by H2SO4Max. 60 APHA
    E/EMax. 0.1 %
    Evaporation residueMax. 10 ppm
    MethanolMax. 0.1 %
    Methyl acetateMax. 0.1 %
    iso-Propyl acetateMax. 0.06 %
    n-Propyl acetateMax. 0.5 %
    WaterMax. 0.03 %
    Al (Aluminium)Max. 0.1 ppm
    B (Boron)Max. 0.02 ppm
    Ba (Barium)Max. 0.02 ppm
    Ca (Calcium)Max. 0.5 ppm
    Cd (Cadmium)Max. 0.05 ppm
    Co (Cobalt)Max. 0.02 ppm
    Cr (Chromium)Max. 0.02 ppm
    Cu (Copper)Max. 0.02 ppm
    Fe (Iron)Max. 0.1 ppm
    K (Potassium)Max. 0.1 ppm
    Mg (Magnesium)Max. 0.05 ppm
    Mn (Manganese)Max. 0.02 ppm
    Na (Sodium)Max. 0.5 ppm
    Ni (Nickel)Max. 0.02 ppm
    Pb (Lead)Max. 0.05 ppm
    Sn (Tin)Max. 0.1 ppm
    Sr (Strontium)Max. 0.02 ppm
    Zn (Zinc)Max. 0.1 ppm
    Conforms to ACSPasses test
    Conforms to Reag. Ph.Eur.Passes test

    Product Specification not found.
    Resources file not found.

    Accessory Products


    Add a Review

    Rate this Product  
    Name *
    Email *

    Your Review *
    7645





    0

    1  Reviews
    (0) 
    (0) 
    (0) 
    (0) 
    (0) 

    Customer Review




    Image

    March 03 2025

    Richard Atule - bought VWR® BDH Ethyl Acetate ≥99.5%, Analar Normapur® Acs, Reag. Ph. Eur. Analytical Reagent, 2.5L

    @Roland Quagraine @Millicent Adjei do you have this available in Accra?

    Showing 1 Of 1